Description

What are Vertical and Horizontal Laminar Flow Hoods?
Laminar flow hoods, also known as clean benches, provide filtered airflow across the work area to prevent sample contamination. These hoods are suitable for various applications that require a sterile environment and clean air, such as medical and research laboratories, sterile equipment assembly, and electronic device assembly.
Laminar flow hoods typically have either horizontal or vertical airflow. In vertical flow hoods, clean filtered air flows downward from the filter surface on top to the work surface. In horizontal laminar flow cabinets, clean air travels from a filter located behind the work surface towards the operator. The airflow direction is influenced by the procedure type, operator safety, and clearance requirements.
Esco Multi-Zone ART Workstations are vertical airflow laminars that provide filtered air from the top of the workstation towards the working surface for the most optimal safety assurance.
Applications
Personnel protection is not provided by laminar flow hoods or clean benches, as it is done by biosafety cabinets. In the presence of harmful substances, they are ineffective. A biological safety cabinet should be utilized if your application concerns biohazard material.
Multi-zone Workstations are primarily used for In Vitro Fertilization/Assisted Reproductive Treatment, Sample Handling, and are generally suited for non-hazardous applications requiring a clean work environment.
Features

Multi-Zone heating system

Multi-Zone ART Workstations utilize ten distinct zones, each equipped with its own heating elements and sensors, to achieve excellent uniformity. The heating system automatically prioritizes power distribution to ensure accurate temperature regulation and quick recovery. The temperature regulation is constantly active in models with MIRI® chambers, regardless of mode, and there is no crossover of heating across zones. Additionally, the heated glass stage has its own independent heating zone to further enhance temperature control and recovery in this area.

 

Choice of 4 temperature modes

In the Multi-Zone ART workstation, the user can turn on all zones, turn off the right zones, turn off the right and middle zones, or turn off all zones.

Microscope integration

  • It is possible to integrate the most popular stereoscopic and inverted microscopes.
  • Integrated stereoscope allows users to keep culture dishes at a constant temperature while observing and manipulating them. By limiting unnecessary movements, it is possible to significantly reduce the probability of accidents occurring.

Humidification system

Multi-Zone ART Workstations do not facilitate active humidification level control – it is done passively by transferring gas through water in the humidification bottle. For Workstation models without integrated MIRI® chambers, the gas outlet port in the front can be sealed by a plastic cover and a tube, creating a “semi-closed” environment.

Energy Efficiency

ECM blowers are used in Esco Assisted Reproductive Technology Workstations, enabling minimal cabinet power consumption without sacrificing cabinet performance. It also has a standby mode that helps to save energy while the cabinet is not in use.

Touchscreen monitor

Multi-Zone ART Workstations come with a fully functional Windows PC integrated. This touch-sensitive computer allows the user to:

  • Monitor the temperature of the heated surface, as well as the gas flow and pressure, and generate reports of those parameters.
  • Observe and record cultural behavior in real time via the microscope’s camera.
  • Have teleconference calls with colleagues on other sites for real-time collaborative work.

Isocide Powder Coat

All Multi-Zone ART Workstations are coated with a silver-ion-impregnated powder that improves the safety of the workstation by inhibiting the growth of microbes.

Stainless Steel Tabletop

  • The construction of Multi-Zone ART Workstations incorporates stainless steel for the tabletop surfaces, complemented by the utilization of aluminum to encase the underside of the tabletops. This feature ensures the sturdiness of the work surface while at the same time minimizing the weight of the whole workstation.

Superior Air Cleanliness

Multi-Zone ART Workstations ensure ISO Class 3 air cleanliness, surpassing Class 4 competitors.

Less Noise, Less Vibration

Multi-Zone ART Workstation offers cutting-edge design and features that result in extremely low noise and vibration levels, making it ideal for sensitive microscopic work. It has a smaller, high-efficiency ECM blower that creates less noise and vibrations, as well as a passive damper that runs the length of the link, dampening the cabinet frame with table plate vibrations.

Cable Pass-Through Channels

Multi-Zone  ART workstation has a convenient way for electrical cables of other equipment and/or accessories (i.e., a camera) to pass through its back wall. This provides a cleaner and more organized interior that should help improve your IVF workflow.
Specifications
Feature Specification
Heating Zones 9 heated tabletop zones + 1 heated glass stage (total 10)
Temperature Accuracy ±0.2 °C
Air Quality Standard ISO Class 3 (Vertical Laminar Flow with ULPA filtration)
Temperature Modes 4 programmable zone operation modes
Built-in Monitoring Touchscreen PC for temp/gas monitoring, image capture, data logging
Microscope Integration Compatible with stereo & inverted microscopes
Optional Add-ons MIRI® incubation chambers, tri-gas mixer, UV lamp, AVT platform
Cabinet Sizes 4-ft and 6-ft models available
Power Supply Configurable (100-240V, 50/60Hz) depending on region
Gas Humidification Integrated with gas flow monitoring

Reviews

There are no reviews yet.

Be the first to review “Multi-Zone ART Workstation”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMulti-Zone ART Workstation removeDiscover 5 Panel Cup with Adulterants Per Pack removeEppendorf Minispin Centrifuge removeAvalun 48 INR Microcuvette remove8 Bucket Centrifuge removeSugentech Inclix (POCT) Immunoassay Analyzer remove
NameMulti-Zone ART Workstation removeDiscover 5 Panel Cup with Adulterants Per Pack removeEppendorf Minispin Centrifuge removeAvalun 48 INR Microcuvette remove8 Bucket Centrifuge removeSugentech Inclix (POCT) Immunoassay Analyzer remove
ImageDrug Test CupAvalun 48 INR Microcuvette
SKUSF1033560084-23SF1033560084-116SF1033560084-74SF1033560084-114SF1033560084-89
Rating
Price

$0.00

$0.00

$0.00

$0.00

$72.50

$0.00

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad Multi-Zone ART Workstation is a vertical laminar flow workstation with multiple heating zones that enable precise temperature control across the work surface, with the provision to have a built-in microscope and integrated MIRI® chambers. Available in different sizes and configurations.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
What are Vertical and Horizontal Laminar Flow Hoods?
Laminar flow hoods, also known as clean benches, provide filtered airflow across the work area to prevent sample contamination. These hoods are suitable for various applications that require a sterile environment and clean air, such as medical and research laboratories, sterile equipment assembly, and electronic device assembly.
Laminar flow hoods typically have either horizontal or vertical airflow. In vertical flow hoods, clean filtered air flows downward from the filter surface on top to the work surface. In horizontal laminar flow cabinets, clean air travels from a filter located behind the work surface towards the operator. The airflow direction is influenced by the procedure type, operator safety, and clearance requirements.
Esco Multi-Zone ART Workstations are vertical airflow laminars that provide filtered air from the top of the workstation towards the working surface for the most optimal safety assurance.
Applications
Personnel protection is not provided by laminar flow hoods or clean benches, as it is done by biosafety cabinets. In the presence of harmful substances, they are ineffective. A biological safety cabinet should be utilized if your application concerns biohazard material.
Multi-zone Workstations are primarily used for In Vitro Fertilization/Assisted Reproductive Treatment, Sample Handling, and are generally suited for non-hazardous applications requiring a clean work environment.
Features

Multi-Zone heating system

Multi-Zone ART Workstations utilize ten distinct zones, each equipped with its own heating elements and sensors, to achieve excellent uniformity. The heating system automatically prioritizes power distribution to ensure accurate temperature regulation and quick recovery. The temperature regulation is constantly active in models with MIRI® chambers, regardless of mode, and there is no crossover of heating across zones. Additionally, the heated glass stage has its own independent heating zone to further enhance temperature control and recovery in this area.

 

Choice of 4 temperature modes

In the Multi-Zone ART workstation, the user can turn on all zones, turn off the right zones, turn off the right and middle zones, or turn off all zones.

Microscope integration

  • It is possible to integrate the most popular stereoscopic and inverted microscopes.
  • Integrated stereoscope allows users to keep culture dishes at a constant temperature while observing and manipulating them. By limiting unnecessary movements, it is possible to significantly reduce the probability of accidents occurring.

Humidification system

Multi-Zone ART Workstations do not facilitate active humidification level control – it is done passively by transferring gas through water in the humidification bottle. For Workstation models without integrated MIRI® chambers, the gas outlet port in the front can be sealed by a plastic cover and a tube, creating a “semi-closed” environment.

Energy Efficiency

ECM blowers are used in Esco Assisted Reproductive Technology Workstations, enabling minimal cabinet power consumption without sacrificing cabinet performance. It also has a standby mode that helps to save energy while the cabinet is not in use.

Touchscreen monitor

Multi-Zone ART Workstations come with a fully functional Windows PC integrated. This touch-sensitive computer allows the user to:

  • Monitor the temperature of the heated surface, as well as the gas flow and pressure, and generate reports of those parameters.
  • Observe and record cultural behavior in real time via the microscope’s camera.
  • Have teleconference calls with colleagues on other sites for real-time collaborative work.

Isocide Powder Coat

All Multi-Zone ART Workstations are coated with a silver-ion-impregnated powder that improves the safety of the workstation by inhibiting the growth of microbes.

Stainless Steel Tabletop

  • The construction of Multi-Zone ART Workstations incorporates stainless steel for the tabletop surfaces, complemented by the utilization of aluminum to encase the underside of the tabletops. This feature ensures the sturdiness of the work surface while at the same time minimizing the weight of the whole workstation.

Superior Air Cleanliness

Multi-Zone ART Workstations ensure ISO Class 3 air cleanliness, surpassing Class 4 competitors.

Less Noise, Less Vibration

Multi-Zone ART Workstation offers cutting-edge design and features that result in extremely low noise and vibration levels, making it ideal for sensitive microscopic work. It has a smaller, high-efficiency ECM blower that creates less noise and vibrations, as well as a passive damper that runs the length of the link, dampening the cabinet frame with table plate vibrations.

Cable Pass-Through Channels

Multi-Zone  ART workstation has a convenient way for electrical cables of other equipment and/or accessories (i.e., a camera) to pass through its back wall. This provides a cleaner and more organized interior that should help improve your IVF workflow.
Specifications
Feature Specification
Heating Zones 9 heated tabletop zones + 1 heated glass stage (total 10)
Temperature Accuracy ±0.2 °C
Air Quality Standard ISO Class 3 (Vertical Laminar Flow with ULPA filtration)
Temperature Modes 4 programmable zone operation modes
Built-in Monitoring Touchscreen PC for temp/gas monitoring, image capture, data logging
Microscope Integration Compatible with stereo & inverted microscopes
Optional Add-ons MIRI® incubation chambers, tri-gas mixer, UV lamp, AVT platform
Cabinet Sizes 4-ft and 6-ft models available
Power Supply Configurable (100-240V, 50/60Hz) depending on region
Gas Humidification Integrated with gas flow monitoring
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Features:
  • Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
  • Max. speed: 14,100 x g (14,500 rpm)
  • Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
  • Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
  • Rotor can be autoclaved at 121°C for 20 minutes
  • Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
  • Eliminate costly repairs with the low maintenance drive
  • Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: 800 – 13,400 rpm (100 rpm steps)
Capacity: 12 x 1.5/2.0 mL
Electrical: 120 V, 60 Hz
Dimensions: (W x D x H) 22.6 x 23.9 x 12.0 cm
Weight: 4.3 kg
 
Click Here To Download Catalogue
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare