/ /

Multigas Monitor AneSure-H

$0.00

Shipped From Abroad

AneSure-H is a safe and reliable anesthesia gas monitor, which can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130170-13
Brands:: Kingst

Description

Features of AneSure Handheld Anesthesia Multigas Monitor AneSure-H
  • Specially-designed Water filter

Water filters can be used for working under a heavy humid environment, also suitable for intubated or non-intubated patients.

Economic

An Economic Multi-gas monitor that supports safe agent administration.

  • Automatic atmospheric pressure compensation

Automatically adjust atmospheric pressure compensation according to altitude conditions

  • Reliable and Accurate

Based on Kingst’s mature technology of infrared gas analysis.

  • Alarm For Data Overrun And Suffocation

Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off

anesthetic gas analyzer
Specifications of AneSure Handheld Multigas Monitor AneSure-H
AC Input 100V – 240V, 50Hz/60 Hz to 5VDC Adapter with 5V mini USB adapter Cable. Optional Vehicle 12V to 5V Mini USB Charger Lead.
Battery Built-in rechargeable lithium battery pack,(3.7V, 3500mAH)
Temperature 5 to +50℃
Humidity < 93% (non-condensing) = < 29.45 hPa
Atmospheric pressure 70 – 120 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Sidestream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v)

Accuracy: ±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

Update/Averaging Time Option of every breath or 10, 20, or 30 seconds
Sample Flow Rate 50–250ml/min User Adjustable. Default=100ml/min <±20% for sample flow rate ranges from 50–250ml/min
FiN2O/EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading)

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified

FiSEV/EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified

FiDES/EtDES measurement Range: 0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified

All FiAG Update: every 2-3 breath

Trends: 24 hours on Screen Trend and Numeric

Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 – 150 breaths/minute

Accuracy: ±1% of reading or ±1 breaths/min whichever is greater

SpO2 (optional) Range: 0 – 100%

Accuracy: ±2% for SpO2 range from 70 – 100%, 70% of the following does not require

Pulse Rate (optional) Range: 30 – 250bpm

Accuracy: 30 Beats/min~40 Beats/min, error±2 Beats/min;

41 Beats/min~250 Beats/min, error±2 Beats/min (Absolute value) or a maximum of ± 2% (Relative value)

Rise time CO2 is less than 200ms;

N2O is less than 300ms;

Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms

Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec

High alarm limits EtCO2/ FiCO2:22-150mmHg

Low alarm limits EtCO2/ FiCO2: 00-60mmHg

High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0%

Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5%

High alarm limits FiSEV/EtSEV:1.0-10.0%

Low alarm limits FiSEV/EtSEV:0-6.5%

High alarm limits FiDES/EtDES:1.0-18.0%

Low alarm limits FiDES/EtDES: 0-6.5%

High alarm limits FiN2O/EtN2O:26-100%

Low alarm limits FiN2O/EtN2O: 01-78%

The high alarm limits of respiration rate:4-150 breaths/min

The low alarm limits of respiration rate:0-140 breaths/min

The high alarm limits of SpO2:off

The low alarm limits of SpO2:50-100%

The high alarm limits of Pulse Rate:70-250 bpm

The low alarm limits of Pulse Rate:30-100 bpm

Size 70 x 160 x 40mm (W x H x D)
Weight Monitor 380g, Weight on Airway ETT/LMA<25g
Warranty & Maintenance/ Calibration One-year warranty on main unit and lithium-ion rechargeable battery Auto self-zeroing calibration, annual calibration check recommended

 

Application Scenarios of AneSure Handheld Multigas Monitor AneSure-H
  • AneSure-H is a portable accurate anesthesia multi-gas monitor.
  • Equipped with a specially designed water filter, AneSure-H can work continuously for a long time in a high-humidity environment, and is suitable for both intubated and non-intubated patients;
  • AneSure-H is a safe and reliable anesthesia gas monitor, that can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia;
  • And there is an internal barometer for automatic pressure compensation.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs;
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour graphs will not be lost when power off;

Reviews

There are no reviews yet.

Be the first to review “Multigas Monitor AneSure-H”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsMultigas Monitor AneSure-H removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeTimesco Eclipse McCoy Laryngoscope Set removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeSpinal Epidural Pack removeTimesco Jumper Fingertip Pulse Oximeter remove
NameMultigas Monitor AneSure-H removeCryoIQ CIQ-DP-L- Cryo DERM Plus Liquid Device with LED Light (CiQ-A-LED) removeTimesco Eclipse McCoy Laryngoscope Set removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeSpinal Epidural Pack removeTimesco Jumper Fingertip Pulse Oximeter remove
ImageTimesco Eclipse McCoy Laryngoscope SetFingertip Pulse Oximeter
SKUSF1033560130170-13SF1033560096-4SF1033560084-54SF1033560011-12SF1033560084-25SF1033560084-2
Rating
Price

$0.00

$0.00

$0.00

$1,320.00

$0.00

$17.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad AneSure-H is a safe and reliable anesthesia gas monitor, which can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of AneSure Handheld Anesthesia Multigas Monitor AneSure-H
  • Specially-designed Water filter
Water filters can be used for working under a heavy humid environment, also suitable for intubated or non-intubated patients. Economic
An Economic Multi-gas monitor that supports safe agent administration.
  • Automatic atmospheric pressure compensation
Automatically adjust atmospheric pressure compensation according to altitude conditions
  • Reliable and Accurate
Based on Kingst's mature technology of infrared gas analysis.
  • Alarm For Data Overrun And Suffocation
Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off
anesthetic gas analyzer
Specifications of AneSure Handheld Multigas Monitor AneSure-H
AC Input 100V - 240V, 50Hz/60 Hz to 5VDC Adapter with 5V mini USB adapter Cable. Optional Vehicle 12V to 5V Mini USB Charger Lead.
Battery Built-in rechargeable lithium battery pack,(3.7V, 3500mAH)
Temperature 5 to +50℃
Humidity < 93% (non-condensing) = < 29.45 hPa
Atmospheric pressure 70 - 120 kPa
Technique NDIR (Non-dispersive infrared gas analysis)
Sampling Mode Sidestream
EtCO2, FiCO2 measurement Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v) Accuracy: ±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
Update/Averaging Time Option of every breath or 10, 20, or 30 seconds
Sample Flow Rate 50–250ml/min User Adjustable. Default=100ml/min <±20% for sample flow rate ranges from 50–250ml/min
FiN2O/EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading)
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified
FiSEV/EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified
FiDES/EtDES measurement Range: 0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified
All FiAG Update: every 2-3 breath Trends: 24 hours on Screen Trend and Numeric
Atmospheric Pressure Compensation Auto-compensation for atmospheric pressure variation
Respiration Rate Range: 3 - 150 breaths/minute Accuracy: ±1% of reading or ±1 breaths/min whichever is greater
SpO2 (optional) Range: 0 - 100% Accuracy: ±2% for SpO2 range from 70 - 100%, 70% of the following does not require
Pulse Rate (optional) Range: 30 – 250bpm Accuracy: 30 Beats/min~40 Beats/min, error±2 Beats/min; 41 Beats/min~250 Beats/min, error±2 Beats/min (Absolute value) or a maximum of ± 2% (Relative value)
Rise time CO2 is less than 200ms; N2O is less than 300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms
Warm Up Time <15 seconds
Agent threshold 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected
Alarm limits Apnea alarm limits:15-40 sec High alarm limits EtCO2/ FiCO2:22-150mmHg Low alarm limits EtCO2/ FiCO2: 00-60mmHg High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0% Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5% High alarm limits FiSEV/EtSEV:1.0-10.0% Low alarm limits FiSEV/EtSEV:0-6.5% High alarm limits FiDES/EtDES:1.0-18.0% Low alarm limits FiDES/EtDES: 0-6.5% High alarm limits FiN2O/EtN2O:26-100% Low alarm limits FiN2O/EtN2O: 01-78% The high alarm limits of respiration rate:4-150 breaths/min The low alarm limits of respiration rate:0-140 breaths/min The high alarm limits of SpO2:off The low alarm limits of SpO2:50-100% The high alarm limits of Pulse Rate:70-250 bpm The low alarm limits of Pulse Rate:30-100 bpm
Size 70 x 160 x 40mm (W x H x D)
Weight Monitor 380g, Weight on Airway ETT/LMA<25g
Warranty & Maintenance/ Calibration One-year warranty on main unit and lithium-ion rechargeable battery Auto self-zeroing calibration, annual calibration check recommended
 
Application Scenarios of AneSure Handheld Multigas Monitor AneSure-H
  • AneSure-H is a portable accurate anesthesia multi-gas monitor.
  • Equipped with a specially designed water filter, AneSure-H can work continuously for a long time in a high-humidity environment, and is suitable for both intubated and non-intubated patients;
  • AneSure-H is a safe and reliable anesthesia gas monitor, that can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia;
  • And there is an internal barometer for automatic pressure compensation.
  • It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs;
  • The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour graphs will not be lost when power off;
CryoIQ device is perfectly fitted for treatment of warts and other common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage thus giving a maximum use of the gas content. Areas of application are general practice, dermatology, pediatrics, podiatry, aesthetics, veterinary and gynecology/urology. The device uses a state-of-the-art cooling technology that does not require handling of potentially dangerous gases and liquids meaning that the gas cartridge is safely replaced when empty. The device features an ergonomic design where the cooling medium is evenly, accurately and economically distributed by depressing the metering lever. Features:
  • Simple pencil type grip for an easy and very accurate application
  • Freezing temperature
    • Liquid spray freezing, -89°C / -128°F
  • Level of cold generated is adjusted by the rate at which the metering lever is depressed
  • CE marked according to Medical Device IIa
  Technical Specifications: Name: CryoIQ® DERM plus Liquid Order.no: CIQ-DP-L Delivered in: Plastic case Included in delivery: 1 gas cartridge (16 gram) with valve Weight: 82 gram (including 16 gram cartridge) Dimensions: Diameter: 22 mm / Length: 120 mm Freezing temperature: -89°C / -128°F Material: Gold plated metal Patented: Yes CE marked: According to medical device IIA Warranty: 1 years (2 years after Product registration) Gas cartridge: 16 or 25 gram Nitrous Oxide Gas (N2O) Medical sterile Built-in filter (5 µm)  
Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
  • The non-replaceable glass fibre bundle is fully enclosed in the blade which allows easy cleaning.
  • Rigid metal construction from fully autoclaveable, antimagnetic stainless steel.
  • Lever positioned at the rear of the blade to control the tilting tip.
  • 3 metal ball bearings for secure fitting.
  • Green ISO 7376 fitting metal block compatible with fibre optic handles.
  • Tilting tip for elevation of the epiglottis, providing an improved view of the larynx, without excessive force.
  • Atraumatic distal end.
  • Fully autoclaveable metal blade, covered by a 5 year guarantee or 4,000 autoclaves, whichever is sooner.
Click Here To Download Catalogue
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
 
Click Here To download Catalogue
   
 
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare