Multigas Monitor AneSure-H
$0.00
Shipped From Abroad
AneSure-H is a safe and reliable anesthesia gas monitor, which can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features of AneSure Handheld Anesthesia Multigas Monitor AneSure-H
- Specially-designed Water filter
 
Water filters can be used for working under a heavy humid environment, also suitable for intubated or non-intubated patients.
Economic
An Economic Multi-gas monitor that supports safe agent administration.
- Automatic atmospheric pressure compensation
 
Automatically adjust atmospheric pressure compensation according to altitude conditions
- Reliable and Accurate
 
Based on Kingst’s mature technology of infrared gas analysis.
- Alarm For Data Overrun And Suffocation
 
Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off

Specifications of AneSure Handheld Multigas Monitor AneSure-H
| AC Input | 100V – 240V, 50Hz/60 Hz to 5VDC Adapter with 5V mini USB adapter Cable. Optional Vehicle 12V to 5V Mini USB Charger Lead. | 
| Battery | Built-in rechargeable lithium battery pack,(3.7V, 3500mAH) | 
| Temperature | 5 to +50℃ | 
| Humidity | < 93% (non-condensing) = < 29.45 hPa | 
| Atmospheric pressure | 70 – 120 kPa | 
| Technique | NDIR (Non-dispersive infrared gas analysis) | 
| Sampling Mode | Sidestream | 
| EtCO2, FiCO2 measurement | Range: 0 – 150mmHg or 0 – 20kPa or 0 – 19.7% (v/v)
 Accuracy: ±2mmHg for CO2 range 0 – 40mmHg ±5% for CO2 range from 41 – 70mmHg ±8% for CO2 range from 71 – 100mmHg ±10% Over 100mmHg  | 
| Update/Averaging Time | Option of every breath or 10, 20, or 30 seconds | 
| Sample Flow Rate | 50–250ml/min User Adjustable. Default=100ml/min <±20% for sample flow rate ranges from 50–250ml/min | 
| FiN2O/EtN2O measurement | Range: 0-100%
 Accuracy: ± (2 vol% + 2% of reading)  | 
| FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement | Range: 0-12%
 Accuracy: 0-8%: ± (0.15 vol% + 5% of reading); 8-12%: unspecified  | 
| FiSEV/EtSEV measurement | Range: 0-15%
 Accuracy: 0-10%: ± (0.15 vol% + 5% of reading); 10-15%: unspecified  | 
| FiDES/EtDES measurement | Range: 0-25%
 Accuracy: 0-18%: ± (0.15 vol% + 5% of reading); 18-25%: unspecified  | 
| All FiAG | Update: every 2-3 breath
 Trends: 24 hours on Screen Trend and Numeric  | 
| Atmospheric Pressure Compensation | Auto-compensation for atmospheric pressure variation | 
| Respiration Rate | Range: 3 – 150 breaths/minute
 Accuracy: ±1% of reading or ±1 breaths/min whichever is greater  | 
| SpO2 (optional) | Range: 0 – 100%
 Accuracy: ±2% for SpO2 range from 70 – 100%, 70% of the following does not require  | 
| Pulse Rate (optional) | Range: 30 – 250bpm
 Accuracy: 30 Beats/min~40 Beats/min, error±2 Beats/min; 41 Beats/min~250 Beats/min, error±2 Beats/min (Absolute value) or a maximum of ± 2% (Relative value)  | 
| Rise time | CO2 is less than 200ms;
 N2O is less than 300ms; Anesthetic gases (halothane, enflurane, isoflurane, sevoflurane, or desflurane) are less than 300ms  | 
| Warm Up Time | <15 seconds | 
| Agent threshold | 0.2%, When an agent is identified, concentrations will be reported even below 0.2% as long as apnea is not detected | 
| Alarm limits | Apnea alarm limits:15-40 sec
 High alarm limits EtCO2/ FiCO2:22-150mmHg Low alarm limits EtCO2/ FiCO2: 00-60mmHg High alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:1.0-8.0% Low alarm limits FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO:0-6.5% High alarm limits FiSEV/EtSEV:1.0-10.0% Low alarm limits FiSEV/EtSEV:0-6.5% High alarm limits FiDES/EtDES:1.0-18.0% Low alarm limits FiDES/EtDES: 0-6.5% High alarm limits FiN2O/EtN2O:26-100% Low alarm limits FiN2O/EtN2O: 01-78% The high alarm limits of respiration rate:4-150 breaths/min The low alarm limits of respiration rate:0-140 breaths/min The high alarm limits of SpO2:off The low alarm limits of SpO2:50-100% The high alarm limits of Pulse Rate:70-250 bpm The low alarm limits of Pulse Rate:30-100 bpm  | 
| Size | 70 x 160 x 40mm (W x H x D) | 
| Weight | Monitor 380g, Weight on Airway ETT/LMA<25g | 
| Warranty & Maintenance/ Calibration | One-year warranty on main unit and lithium-ion rechargeable battery Auto self-zeroing calibration, annual calibration check recommended | 
Application Scenarios of AneSure Handheld Multigas Monitor AneSure-H
- AneSure-H is a portable accurate anesthesia multi-gas monitor.
 - Equipped with a specially designed water filter, AneSure-H can work continuously for a long time in a high-humidity environment, and is suitable for both intubated and non-intubated patients;
 - AneSure-H is a safe and reliable anesthesia gas monitor, that can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia;
 - And there is an internal barometer for automatic pressure compensation.
 - It has an alarm function, which will alarm when the measured value reaches the alarm limits or when suffocation occurs;
 - The first data can be obtained within 5 seconds after power-on, and full accurate data can be obtained within 15 seconds; the 24-hour graphs will not be lost when power off;
 
Quick Comparison
| Multigas Monitor AneSure-H remove | Render SD-M2000A(P) Transport/Portable Anesthetic Machine remove | Siare Morpheus E Anaesthetic Machine remove | Siare Morpheus M Anaesthetic Machine remove | Spinal Epidural Pack remove | Bistos BT-770-12.1" Touchscreen Patient Monitor remove | |||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | Multigas Monitor AneSure-H remove | Render SD-M2000A(P) Transport/Portable Anesthetic Machine remove | Siare Morpheus E Anaesthetic Machine remove | Siare Morpheus M Anaesthetic Machine remove | Spinal Epidural Pack remove | Bistos BT-770-12.1" Touchscreen Patient Monitor remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| Image | ![]()  | ![]()  | ![]()  | ![]()  | ![]()  | ![]()  | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| SKU | SF1033560130170-13 | SF1033560011-12 | SF1033560101-1 | SF1033560101-2 | SF1033560084-25 | SF1033560059-1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Price | 
  | $1,320.00  | 
  | 
  | 
  | $902.00  | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Description | Shipped From Abroad
AneSure-H is a safe and reliable anesthesia gas monitor, which can guide anesthesiologists to use anesthesia gas to ensure the safety of patients during anesthesia.
 Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. 
 | Shipped from Abroad
  | Shipped from Abroad The MORPHEUS E is an anaesthesia machine with electronic flowmeters and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.
 Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad The Bistos BT-770 patient monitor is equipped with a 12.1" touchscreen display, which allows for an easy operation and readability with a powerful rechargeable battery guaranteeing a continuous operation of 5 hours to monitor ECG, SpO2, NIBP, temperature and respiration Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| Content | Features of AneSure Handheld Anesthesia Multigas Monitor AneSure-H
 
Water filters can be used for working under a heavy humid environment, also suitable for intubated or non-intubated patients.
Economic
 
An Economic Multi-gas monitor that supports safe agent administration.
 
 
Automatically adjust atmospheric pressure compensation according to altitude conditions
 
 
Based on Kingst's mature technology of infrared gas analysis.
 
 
Quick warm-up with the first value displayed in 5 seconds, and accurate readings displayed in 15 seconds. 24-hour trend graphs, not lost when power off
 
![]() Specifications of AneSure Handheld Multigas Monitor AneSure-H
 Application Scenarios of AneSure Handheld Multigas Monitor AneSure-H
  | 
 Click Here To download Catalogue | The MORPHEUS E is an anaesthesia machine with Electronic Flowmeters and it can be used on adult, children and newborn patients. The MORPHEUS E is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.
Features:
 Click Here To Download Catalogue | The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures.
Features:
 Click Here To Download Catalogue) | It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.
Component:
  | 
Bistos BT-770 is a 12.1" touchscreen patient monitor designed for easy operations.
SPECIFICATIONS
 
 Click Here To Download Catalogue | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| Additional information | 
									





				
				
						
				
				
				
				
				
				
						
				
			
				
Reviews
There are no reviews yet.