Neonatal Warming and Resuscitation Table 2100A
$0.00
Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Features
- Automatic warm-up
- Pre-warm (33 oC) & Manual mode (0-100% in 5% increments)
- Surface temperature servo control (30-38 oC)
- Skin temp. servo control (32-38 oC increments 0.1 oC) with reusable sensor
- Heavy duty stand with 4 castors (2 lockable, 150 mm)
- Protector bumpers on each side & handle on front
- Foldable side walls (4 pcs, height 17,5 cm) w/ name plate
- Tube ports & measure line on side walls
- Lying surface w/ antidecubitus mattress, x-ray compatible
- Cradle tilting (continuous, up to 10 degrees, both direction)
- Drawable x-ray cassette tray (35 x 65 cm)
- Turnable head by 30 and 90 degrees both direction
- Ceramic heaters with parabolic reflectors and protecting grid
- Cupboard with two drawers (300x300x90 mm)
- Gas cylinder holders (two) on the stand
- Monitor shelves (two) & IV pole on the column
- Dimmable halogen & LED procedure light
- 5” LCD display with APGAR timer
- Set / Display of date / time / temperature / trend, etc.
- Water resistant, foil-covered keypad with lock
- State-of-the-art microprocessor controller
- Visual and audible alarms and backup sensors
- Continuous self-test function during operation
- Test button / Self test / Silence / Reset button
- RS-232 connector
- 230V/50Hz+/-10% (230V/60Hz or 110V/50-60Hz on request)
Technical data
PHYSICAL ATTRIBUTES (STANDARD VERSION) | |
---|---|
Height / Adjustable / Packing | 185/185-200/112 cm (72,8/72-78,7/44,1 in) |
Width / Packing | 120/127 cm (47,2/50 in) |
Depth / Packing | 71/81 cm (28/31,9 in) |
Bed to Floor (fix) | 87 cm (33,5 in) |
Bed to Floor (adjustable) | 87 – 102 cm (33,5 – 39,4 in) |
Weight / Packing approx. | 90/120 kg (199/265 lbs) |
Mains voltage | 220/230V ±10% (default), 110/120V ±10% (upon request) |
Mains frequency | 50 Hz (default), 60 Hz (upon request) |
Nominal power consumption | 1100W |
Nominal power of ceramic heaters (2 pcs) | 500 W |
Operating ambient temperature range | +20°C – +30°C (68oF – 86oF) |
Storage/transport ambient temperature range | -40oC – +70oC (-40oF – 158oF) |
Operating (Storage) ambient RH range | 30% – 75% (10% – 100%) |
Operating (Storage) air pressure range | 700 hPa – 1060 hPa (500 hPa – 1060 hPa) |
LYING SURFACE (BED) SPECIFICATION | |
Surface size | 61 x 76 cm (24 x 29,9 in) |
Mattress size | 60 x 75 x 2 cm (23,6 x 29,5 x 0,8 in) |
Mattress to head height | 80 cm (31,5 in) |
TEMPERATURE CONTROL MODES | |
Pre-warm mode | 33.0°C (91.4°F) |
Manual control temperature mode | 0%-100%, in 5% increments |
Surface control temperature range | 30.0°C (86°F) to 38.0°C (100.4°F), in 0.1°C increments |
Skin control temperature range | 32.0°C (89.6°F) to 38.0°C (100.4°F), in 0.1°C increments |
Mattress heating temperature range | 30.0°C (86°F) to 33.0°C (91.4°F), in 1°C increments |
Peripherial skin / Rectal temperature monitoring | Yes |
PERFORMANCE | |
Temperature rise time | 25 °C (77°F) ambient < 30 min |
Temperature variability | under 0.5°C (0.9°F) |
Temperature uniformity on the surface of the mattress | under 0.7°C (1.2°F) |
Correlation of the indicated air temperature with the actual surface temperature | ≤ 0.7°C (1.2°F) |
Display precision of skin temperature | under ±0.1°C (0.1°F) |
Measuring precision of skin temperature sensor | under ±0.3°C (0.5°F) |
APGAR warning signal after | 1 / 5 / 10 min |
OXYGEN SERVO CONTROL | |
Oxygen control range | 21% to 90% (head hood) |
Oxygen control accuracy of full scale | ± 3% |
Oxygen display accuracy (100% calibration) | ± 3% |
Oxygen display accuracy (21% calibration) | ± 3% |
Oxygen display resolution | 1% |
WEIGHING SCALE | |
Weight range | 0 to 8 kg (17,1 lbs) |
Weight display resolution | 5 gr or 0,2 oz |
Weight accuracy up to | 5 kg ± 5 gr, over 5 kg ± 10 gr |
Low voltage alarm | |
LOADING | |
Max. load of mattress | 10 kg (22,1 lbs) |
Max. load of IV pole | 2 kg (4,7 lbs) |
Max load of shelves | 2 kg (4,7 lbs) |
DEVICE CLASSIFICATION | |
Protection class | Class I, Type BF, continuous operation |
Ingress of liquids | IP20 |
Electric safety | IEC 60601-1; IEC 60601-2-21 |
TREND PARAMETERS | |
3/24/170-hour trend | Surface temperature, Skin temperature, Mattress temperature, Peripherial temperature, Oxygen concentration, Heater power |
Quick Comparison
Settings | Neonatal Warming and Resuscitation Table 2100A remove | Scrub Suit remove | Urine Analyzer remove | Syringe Bulb remove | First Aid Box Aluminium Small remove | OPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Neonatal Warming and Resuscitation Table 2100A remove | Scrub Suit remove | Urine Analyzer remove | Syringe Bulb remove | First Aid Box Aluminium Small remove | OPTIKA B-382PL-ALC Binocular Brightfeld Microscope remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF1033560130129-3 | SF1033560084-202 | SF1033560084-224 | SF1033560084-205 | SF1033560084-252 | SF1033560098-13 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
| $11.00 | $540.00 | $1.99 | $49.50 |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In stock
Used for Clinical Diagnostics.
| In stock
Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
| In stock
First Aid Box Aluminium Large contains variety of medical item for emergency rescue, it can contain items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment.
| Shipped from Abroad The OPTIKA B-380 is an educational and laboratory microscope for routine applications. Dye-cast frame, with high stability and ergonomy, for transmitted light observation. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | https://youtu.be/G0AjkyYOQpw
Features
Technical data
|
| Used for Clinical Diagnostics.
| Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
| First Aid Box Aluminium Small contains variety of medical item for emergency rescue, it can contain items from simple digital or disposable thermometers to hard to find first aid items such as medical scissors, and many other items that could help save a situation before being taken to the hospital for proper treatment. | Observation mode: Brightfield.
Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged).
Interpupillary distance: Adjustable between 48 and 75 mm.
Dioptric adjustment: On the left eyepiece tube.
Eyepieces: WF10x/20 mm, high eye-point and secured by screw.
Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
Objectives:
N-PLAN 4x/0.10
N-PLAN 10x/0.25
N-PLAN 40x/0.65
N-PLAN 100x/1.25 (Oil/Water)
All with anti-fungus treatment.
Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range.
Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable.
Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply.
Click Here To Download Catalogue | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.