Neuro-IOM-32/S
$0.00
Shipped From Abroad
Neuro-IOM-32/S is a sophisticated intraoperative monitoring (IOM) system designed for real-time neurological assessment during surgeries. It offers 32 channels for EMG, EEG, and Evoked Potentials (EP), ensuring continuous monitoring of neural functions. This system helps in identifying potential neurological risks during complex surgeries, allowing surgeons and neurophysiologists to make informed decisions and prevent neural damage. With high-resolution diagnostics and a user-friendly interface, the Neuro-IOM-32/S enhances patient safety and optimizes surgical outcomes.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
32-channel System with Basic Functions for Intraoperative Neurophysiological Monitoring
32 bipolar channel system, entry level
This configuration of Neuro-IOM system (version 2) includes all basic functions to perform intraoperative neurophysiological monitoring
Main features:
- 64 amplifier inputs (32 bipolar channels)
- 32-channel amplifier significantly improves the quality of IONM as more conduction pathways are monitored in comparison with 16-channel amplifier.
- 2 dedicated channels for routine EMG, NCS and EP;
- 4 electrical stimulator channels;
- direct nerve stimulation channel;
- auditory, visual and pattern stimulator channels;
- ES detector channels.
The Neuro-IOM system allows performing intraoperative neurophysiological monitoring of all modalities, including MEP acquisition using the electrical stimulator with current intensity of up to 200 mA.
The Neuro-IOM system is equipped with the acquisition and stimulator pods to attach recording and stimulating electrodes with 5 m cables. It allows arranging the system at a distance from the operating table to ensure free movement for the surgical team. The set of specially-designed electrodes and the software are also included to the delivery set.
Motor, somatosensory, auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 modalities for intraoperative neurophysiological monitoring
The Neuro-IOM system is delivered with the preset templates ensuring the following modalities:
- direct nerve stimulation;
- free-run EMG;
- somatosensory evoked potentials (SEP);
- motor evoked potentials (MEP);
- auditory evoked potentials (AEP);
- visual evoked potentials (VEP);
- EEG;
- ECoG;
- direct cortical stimulation;
- train-of-four stimulation (TOF).
Using these modalities the surgical team can control motor and sensory pathways, monitor peripheral nerve integrity, assess the brain activity and perform mapping of its functional areas, etc.
Flexible configurations to ensure any monitoring needs
The Neuro-IOM.NET software provides a set of default templates for various types of surgeries. Each template includes the settings of modalities for a particular type of surgery, test window layouts, acquisition and stimulation parameters, etc. The system has a vast number of channels and stimulators with separate adjustment. Use of preset templates simplifies and speeds up the system setup for surgery.
You can always change and save the settings of any surgery template. It is a unique option for such kind of systems. There is no IONM system in the world that is so flexible!
Applications
- SEP acquisition
- MEP acquisition
- 64 amplifier inputs( 32 bipolar channels)
- auditory and visual evoked potentials, EMG, direct nerve stimulation, EEG, ECoG — more than 10 monitoring modalities
- flexible configurations to ensure any monitoring needs
Quick Comparison
Settings | Neuro-IOM-32/S remove | BRAINSWAY Deep TMS 104 RCT System remove | BRAINSWAY Deep TMS H4 Coil remove | Dolphin-4D Transcranial Doppler Probe remove | Retractors remove | Nitrogen Generator/Plant remove | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Neuro-IOM-32/S remove | BRAINSWAY Deep TMS 104 RCT System remove | BRAINSWAY Deep TMS H4 Coil remove | Dolphin-4D Transcranial Doppler Probe remove | Retractors remove | Nitrogen Generator/Plant remove | ||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||
SKU | SF1033560130187-22 | SF1033560130162-3 | SF1033560130162-7 | SF1033560130142-1 | SF1033560130176-9 | SF103356013077 | ||||||
Rating | ||||||||||||
Price |
|
|
|
|
|
| ||||||
Stock | ||||||||||||
Availability | ||||||||||||
Add to cart | ||||||||||||
Description | Shipped From Abroad
Neuro-IOM-32/S is a sophisticated intraoperative monitoring (IOM) system designed for real-time neurological assessment during surgeries. It offers 32 channels for EMG, EEG, and Evoked Potentials (EP), ensuring continuous monitoring of neural functions. This system helps in identifying potential neurological risks during complex surgeries, allowing surgeons and neurophysiologists to make informed decisions and prevent neural damage. With high-resolution diagnostics and a user-friendly interface, the Neuro-IOM-32/S enhances patient safety and optimizes surgical outcomes.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
BrainsWay's 104 RCT System enables blinded clinical research via a card reader that randomizes selection of sham or Deep TMS stimulation. The sham coil is integrated into the helmet with the treatment coil, producing similar sounds and sensations.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H4 Coil stimulates the bilateral insula and prefrontal cortex. Nearly 1 in 3 patients who completed 18 sessions achieved 4 or more weeks of abstinence from smoking in a large scale, double-blind, multicenter randomized controlled trial. 2 out of 3 patients who quit smoking by the end of treatment remained abstinent for at least an additional three months
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The cutting-edge technology of the standalone Dolphin/4D transcranial Doppler system is the optimal TCD solution for measurements of cerebral blood flow velocities.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.
Delivery & Availability:
Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||
Content | 32-channel System with Basic Functions for Intraoperative Neurophysiological Monitoringhttps://youtu.be/XyI13InME9A?list=PLU2BvNtfeStPOl_izQJDwlLEi6eLCrDEF 32 bipolar channel system, entry level This configuration of Neuro-IOM system (version 2) includes all basic functions to perform intraoperative neurophysiological monitoring Main features:
Applications
| The BrainsWay Deep TMS 104 RCT System is a non-invasive treatment for mental health conditions that uses magnetic pulses to stimulate the brain.
FeaturesThe BrainsWay Deep TMS 104 RCT System has several features, including:
Click here to download Brochure | The BrainsWay Deep TMS H4 Coil is a non-invasive treatment that uses magnetic energy waves to stimulate brain structures associated with addiction and weight loss:
| https://youtu.be/Id0Ma1_lEo0?si=MmwcCTMMPZd_jf6h
Features of Dolphin TCD Machine |
| PSA Industrıal nitrogen generator systems produce gas nitrogen from compressed air from the field where they work, and switch compatible to conventional nitrogen gas source such as tubes or cryogenic liqiud.
ADVANTAGES OF NITROGEN GENERATORS/PLANT
Wide Range Of Applications
![]() | ||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||
Additional information |
Reviews
There are no reviews yet.