Neuro-TES is a Transcranial Electrical Stimulator (TES) designed for precise neuromodulation and intraoperative neuroprotection. It delivers controlled electrical stimulation to the brain and nervous system, aiding in motor cortex mapping, functional monitoring, and rehabilitation. Ideal for neurologists, neurosurgeons, and physiatrists, Neuro-TES ensures safe and effective stimulation, enhancing patient outcomes in neurosurgery and neurorehabilitation. With advanced technology and a user-friendly interface, it provides reliable performance in both clinical and research settings.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Stimulus Intensity – 1000 V
Neuro-TES transcranial electrical stimulator is intended for stimulation of motor cortex to record motor evoked potentials from muscles. These potentials allow to estimate the integrity of motor pathways.
Main Specifications:
- stimulus intensity – 0-1000 V with 5 V step;
- maximum pulse current – 1.5 A;
- pulse duration – 40 μs, 50 μs, 60 μs, 70 μs, 80 μs, 200 μs;
- pulse waveform – biphasic, monophasic;
- stimulation type: single pulse, train, double train, train + pulse;
- number of pulses in train – 1-9.
The electrical stimulator is powered via USB.
Application in Intensive Care Units and Operating Rooms
The electrical stimulator can be used together with IOM system in intensive care units, operating rooms and experimental laboratories of research institutions to:
- estimate the central nervous system state;
- study the human neuromuscular system at intraoperative neurophysiological monitoring.
Synchronization with Neurosoft Diagnostic System or Third-party Equipment
The electrical stimulator can operate as a part of IOM system manufactured by Neurosoft or IOM system of third-party manufacturer.
The synchronization of electrical stimulator with Neurosoft equipment is done via USB. To synchronize the electrical stimulator with IOM systems of third-party manufacturer the trig in/out is used.
4-Channel Electronic Switch
The electrical stimulator can be supplied with a 4-channel electronic switch which is placed in a patient zone in a 5-meter distance from the stimulator and control PC.
You can select the following switch:
- electronic switch;
- mechanical switch with external pod.
Neuro-TES software performs the switching in case the stimulator is used with electronic switch. If the stimulator is supplied with mechanical switch, use knobs on its front panel to perform the switching.
Quick Comparison
| Neuro-TES-Transcranial Electrical Stimulator remove | Dolphin-MAX Transcranial Doppler Probe remove | Ectron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove | VentMed DF-30V-HM BiPAP remove | BRAINSWAY Deep TMS 104 RCT System remove | BRAINSWAY Deep TMS H7 RCT Coil remove | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | Neuro-TES-Transcranial Electrical Stimulator remove | Dolphin-MAX Transcranial Doppler Probe remove | Ectron Ectonustim Series 6 Electroconvulsive Therapy ECT Machine remove | VentMed DF-30V-HM BiPAP remove | BRAINSWAY Deep TMS 104 RCT System remove | BRAINSWAY Deep TMS H7 RCT Coil remove | ||||||||||||||||||
| Image |  |  |  |  |  |  | ||||||||||||||||||
| SKU | SF1033560130187-25 | SF1033560130142-2 | SF10335601235 | SF1033560130180-2 | SF1033560130162-3 | SF1033560130162-6 | ||||||||||||||||||
| Rating | ||||||||||||||||||||||||
| Price | 
 | 
 | 
 | 
 | 
 | 
 | ||||||||||||||||||
| Stock | ||||||||||||||||||||||||
| Availability | ||||||||||||||||||||||||
| Add to cart | ||||||||||||||||||||||||
| Description | Shipped From Abroad
Neuro-TES is a Transcranial Electrical Stimulator (TES) designed for precise neuromodulation and intraoperative neuroprotection. It delivers controlled electrical stimulation to the brain and nervous system, aiding in motor cortex mapping, functional monitoring, and rehabilitation. Ideal for neurologists, neurosurgeons, and physiatrists, Neuro-TES ensures safe and effective stimulation, enhancing patient outcomes in neurosurgery and neurorehabilitation. With advanced technology and a user-friendly interface, it provides reliable performance in both clinical and research settings. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
Transcranial Doppler machine with an integrated rechargeable battery. The Dolphin/MAX is the ideal portable TCD system for measurements of cerebral blood flow in Neurology, ICU, and Neurosurgery settings Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.Delivery & Availability: Typically 3 Months – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
The VentMed DF-30V-HM is a BiPAP (Bilevel Positive Airway Pressure) machine designed for sleep apnea therapy and non-invasive ventilation. It is ideal for individuals with obstructive sleep apnea (OSA), central sleep apnea (CSA), chronic obstructive pulmonary disease (COPD), and other respiratory disorders. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
BrainsWay's 104 RCT System enables blinded clinical research via a card reader that randomizes selection of sham or Deep TMS stimulation. The sham coil is integrated into the helmet with the treatment coil, producing similar sounds and sensations. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex.  Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||
| Content | Stimulus Intensity – 1000 V
Neuro-TES transcranial electrical stimulator is intended for stimulation of motor cortex to record motor evoked potentials from muscles. These potentials allow to estimate the integrity of motor pathways. Main Specifications:
 
 
 | https://youtu.be/Id0Ma1_lEo0?si=-B5sGwSCDZOQi-ZO Features of Dolphin TCD Machine | This machines have been developed from the well-proven Series 5A and 5B ECT apparatus. The series 6+ models incorporate all the features of the corresponding Series 5B versions. Experience has shown that a very few patients sometimes require higher dosage than was available with the earlier machines and the opportunity was therefore taken to produce equipment with a second, higher, output range.
Features:
Constant Current stimulus
Delivered Dosage Displayed
Patient Dynamic Impedance Indicator
Simple Single Dose Control
Technical Specification:
Input Supply: AC 100-120, 210-240 V 40/60 Hz
Load: 70 W
Apparatus Size: 305 x 170 x 105mm (12” x 6.5” x 4”)
Weight: 3.24kg
Low Range: 50-700mC @ 750mA
High Range: 200-100mC @ 900mA
Contents:
Two-hand headpiece: 1
C.S lead: 1
Disposable electrodes: 50
Mains cable: 1
Operating & service manual: 1
Removable stand: 1 Click Here To Download Catalogue | This portable and home-use BiPAP device offers effective sleep therapy and is suitable for patients who require advanced respiratory support Key Features:
 Specifications:
 This BiPAP machine is user-friendly, featuring an intuitive control panel and a clear display, making setup and adjustments easy for both patients and healthcare providers. It ensures stable breathing throughout the night, improving overall sleep quality  | The BrainsWay Deep TMS 104 RCT System is a non-invasive treatment for mental health conditions that uses magnetic pulses to stimulate the brain. 
 FeaturesThe BrainsWay Deep TMS 104 RCT System has several features, including: 
 Click here to download Brochure | The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions: 
 Features
 | ||||||||||||||||||
| Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||
| Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||
| Additional information | 
 
									
 
				 
				 
				 
				 
				 
				 
				 
				 
				 
			 
				
Reviews
There are no reviews yet.