Neuron Spectrum 61..65 EEG

$0.00

Shipped From Abroad

The Neuron-Spectrum 61–65 EEG series offers advanced neurophysiological diagnostic systems with 11 to 39 channels, supporting ICU monitoring, routine EEG, long-term video EEG, and polysomnography. These systems feature real-time impedance monitoring, multimodal stimulation, and high-quality data acquisition for clinical and research applications.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130187-1
Brands:: Neurosoft

Description

 

Features

Flexible software

The advantage of the Neuron-Spectrum.NET software is its wide functionality. You can use the simple interface, or you can customize the software using the special settings.

Before the study, you may choose the pre-defined electrode montage or create your own one depending on the type of test you perform. Using the convenient navigation tools, you can quickly view the recorded EEG curves, highlight artifacts, and arrange epochs. For the advanced analysis of recorded data, the contemporary tools for mathematical analysis of EEG are used. The automatic report is generated using the preset report templates and integrated glossary. The report is easily edited, saved to PDF, printed or sent automatically.

Electrode impedance indication at the lead inputs

The impedance indicators on the amplifier ensure the continuous impedance monitoring during the acquisition, timely correction of electrode placement and good quality of EEG recording.

Operation mode can be switched with just one button on the front panel. The LED indicator next to the button shows the mode: acquisition, EEG monitoring or impedance measurement. It makes the EEG study much easier.

Electrodes and caps of various manufacturers

During the study, the disk, cup and bridge electrodes as well as the electrode caps of different sizes can be applied. They are connected to the amplifier unit via touch-proof connectors and standard plug.

Operation in unshielded environments

The EEG systems of Neuron-Spectrum line can be used in any suitable room, which is convenient for staff and comfortable for patients. The costs for preparing a specialist’s workplace are also reduced significantly. The device is small and USB powered, so you can establish your EEG lab anywhere.

Download Brochure

Reviews

There are no reviews yet.

Be the first to review “Neuron Spectrum 61..65 EEG”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNeuron Spectrum 61..65 EEG removeRESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker removeBRAINSWAY Deep TMS H4 Coil removeOxygen Generator/Plant removeBRAINSWAY Deep TMS H4 RCT Coil removeBRAINSWAY Deep TMS 104 RCT System remove
NameNeuron Spectrum 61..65 EEG removeRESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker removeBRAINSWAY Deep TMS H4 Coil removeOxygen Generator/Plant removeBRAINSWAY Deep TMS H4 RCT Coil removeBRAINSWAY Deep TMS 104 RCT System remove
Image
SKUSF1033560130187-1SF10335601298-1SF1033560130162-7SF103356013076SF1033560130162-8SF1033560130162-3
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Neuron-Spectrum 61–65 EEG series offers advanced neurophysiological diagnostic systems with 11 to 39 channels, supporting ICU monitoring, routine EEG, long-term video EEG, and polysomnography. These systems feature real-time impedance monitoring, multimodal stimulation, and high-quality data acquisition for clinical and research applications.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode.   Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H4 Coil stimulates the bilateral insula and prefrontal cortex. Nearly 1 in 3 patients who completed 18 sessions achieved 4 or more weeks of abstinence from smoking in a large scale, double-blind, multicenter randomized controlled trial. 2 out of 3 patients who quit smoking by the end of treatment remained abstinent for at least an additional three months
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
PSA Medical & Industrial oxygen generator systems produce gas oxygen from compressed air from the field where they work and switch compatible to conventional oxygen gas source such as tubes or cryogenic liquid. Delivery & Availability: Typically, 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The H4 Coil stimulates the bilateral insula and prefrontal cortex. This includes neurons in brain structures associated with addiction. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad BrainsWay's 104 RCT System enables blinded clinical research via a card reader that randomizes selection of sham or Deep TMS stimulation. The sham coil is integrated into the helmet with the treatment coil, producing similar sounds and sensations.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Contenthttps://youtu.be/JDAsx3pO4U8?si=fzekZEwG6_K2pHgL  
Features
Flexible software The advantage of the Neuron-Spectrum.NET software is its wide functionality. You can use the simple interface, or you can customize the software using the special settings. Before the study, you may choose the pre-defined electrode montage or create your own one depending on the type of test you perform. Using the convenient navigation tools, you can quickly view the recorded EEG curves, highlight artifacts, and arrange epochs. For the advanced analysis of recorded data, the contemporary tools for mathematical analysis of EEG are used. The automatic report is generated using the preset report templates and integrated glossary. The report is easily edited, saved to PDF, printed or sent automatically. Electrode impedance indication at the lead inputs The impedance indicators on the amplifier ensure the continuous impedance monitoring during the acquisition, timely correction of electrode placement and good quality of EEG recording. Operation mode can be switched with just one button on the front panel. The LED indicator next to the button shows the mode: acquisition, EEG monitoring or impedance measurement. It makes the EEG study much easier. Electrodes and caps of various manufacturers During the study, the disk, cup and bridge electrodes as well as the electrode caps of different sizes can be applied. They are connected to the amplifier unit via touch-proof connectors and standard plug. Operation in unshielded environments The EEG systems of Neuron-Spectrum line can be used in any suitable room, which is convenient for staff and comfortable for patients. The costs for preparing a specialist’s workplace are also reduced significantly. The device is small and USB powered, so you can establish your EEG lab anywhere. Download Brochure
Progetti Rescue Life 9 is designed for out-of-hospital and hospital use. Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode. Three operating modes: manual, AED, Advisory. Capnography waveform. Auto-test mode verifies device functions, battery status and charge-discharge system with real-time data management and report printing. The IPX4 permits operations under adverse climatic situations.
Rescue Life 9 Technical Specification: General requirements • Dimension: 335x225x360 mm • Weight: 6.5 kg with dual batteries • Electrical: AC 100-240 VAC, 50/60 Hz • Rechargeable Lithium-ion batteries: 15.0 V - 3.2 Ah • Battery Operation Time: >5 hours, with 1 battery >10 hours with 2 batteries • Charge Time: Max. 3 hours • Capacity: 150 shocks with 1 battery or 300 shocks with 2 batteries at 230J fully charged • Software: Voice and text multi-language • Memory: Internal flash for ECG data, events and usage review Defibrillation • Waveform: Biphasic Truncated Exponential (BTE), HiCAP technology (Large storage capacitor) • Impedance: Compensated, range 25-200 Ohm • Charge time: 6 sec for 230 J with the battery fully charged
AED mode • Energy: Fixed energy at 200 J • Protocol: ERC 2015 CPR Guidelines with voice and text prompts • Shockable rhythms: VF with amplitude > 0.15 mV and VT with rhythm >150 bpm • Sensitivity: Shockable rhythm -VF > 95%, -VT > 75% • Specificity: According to ERC 2015, • Normal sinusoidal rhythm > 99% • Asystole and other non-shockable rhythms > 99%
Manual mode • Energy range: 1-230 J (from 1-10 J in 1 J steps; from 10 to 230 J in 10 J steps) • Commands: Multifunction trim knob • Charge and shock button in the front panel • Operating mode: EC G «R» wave synchro or async mode • Indicators: Battery and main led indicators Display • Type: High contrast TFT colour LCD 8” (800x600 dots) • Information: ECG traces, SpO2, NIBP, EtCO2, TEMP, Heart Rate indicator, filters, alarms and the batteries status • Display mode: Can select 3, 6, 12 ECG leads
Ecg monitoring • Bandwidth: 0.05 - 120 Hz (-3 db) in diagnostic mode 0.6 - 40 Hz (-3 db) in monitoring mode • CMRR: > 98 dbv Input impedance: > 50 Mohm • Input: Patient cable 5 leads (I, II, III, aVL, aVF, aVR, V) - standard Patient cable 10 leads (I, II, III, aVL, aVF, aVR, V1…..V6) - optional • Speed: 5, 10, 25, 50 mm/sec • Filters: 50/60 Hz, EMG Filter, base line • HR range: 20-300 bpm (~2%), digital readout on the display • Alarm: HR max settable 250 bpm; HR min 20 bpm
SpO2 (only 55505-55512) • SpO2 range: 0-100% HR range: 30-250 bpm • Accuracy: 70-100% ~2% for adults with finger clip sensor • Alarm: Adjustable min 50%
Temperature • Probe type: YSI400 compatible • Range: 0 to 50° C • Resolution: ±0.1° C Standard • IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2; IEC 63204, IEC 62366-1 • CE Mark EEC 93/42: Medical device, Class IIb • Isolation: ECG type CF, Defibrillation type BF • Waterproof: Class IP54
The BrainsWay Deep TMS H4 Coil is a non-invasive treatment that uses magnetic energy waves to stimulate brain structures associated with addiction and weight loss: 
  • Treatment
    The H4 Coil is used to treat smoking addiction and weight loss. It generates electromagnetic pulses that stimulate the bilateral insula and prefrontal cortex of the brain.
  • Benefits
    Deep TMS is a well-tolerated treatment that can be integrated into a patient's daily schedule. It's said to have no side effects and no recovery period. Patients may start to feel relief from symptoms within a few weeks.
  • Technology
    The H4 Coil is part of a helmet that contains BrainsWay's patented H-Coils, which are designed to stimulate deeper and broader areas of the brain than traditional TMS coils. The helmet also has a touchscreen interface, adjustable positioning arm, and cooling system.
  • Safety
    The H4 Coil has lower rates of headache, treatment site discomfort, and jaw pain than other coils, but higher rates of general discomfort

Click here to download Brochure

PSA Medical & Industrıal oxygen generator systems produce gas oxygen from compressed air from the field where they work and switch compatible to conventional oxygen gas source such as tubes or cryogenic liqiud.

OXYGEN PURITY - PSA oxygen generators, continuously 90-95% purity oxygen produces.

OXYGEN FLOW - LINAIR TECHNOLOGIES manufactures oxygen generators with capacities from 1 Nm3/h to 1000 Nm3/h.

OXYGEN OUTLET PRESSURE - Oxygen generators produces 4-6 bar oxygen.

ADVANTAGES OF OXYGEN GENERATORS/Plant

  • Consistently high purity guaranteed.

  • Oxygen production according to your needs 24/7.

  • Purity control of instantaneously produced oxygen.

  • Instant monitoring of parameters such as purity, pressure, flow rate on the screen.

  • No need for an extra operator since it works fully automatically.

Features
  • Targets the bilateral insula and prefrontal cortexThe H4 Coil stimulates brain structures associated with addiction. 
  • FDA-cleared for smoking addiction treatmentThe H4 Coil was cleared by the FDA to treat smoking addiction in adults. 
  • Integrated sham coilThe helmet includes a sham coil that has similar acoustic artifacts and scalp sensations as the active coil. This helps maintain blinding. 
  • Embedded in a cushioned, cooled helmetThe H-Coils are integrated into a helmet that includes a touchscreen interface, adjustable positioning arm, and foot pedal operation. 
  • Delivers electromagnetic pulsesThe H4 Coil generates electromagnetic pulses that stimulate neurons in the brain. 
  • Reaches deeper and broader brain regionsThe H-Coil design allows for deeper and broader stimulation than traditional TMS coils. 
  • Noninvasive treatmentDeep TMS is a noninvasive treatment that is well-tolerated and doesn't require a significant recovery period. 

Click here to download Brochure

The BrainsWay Deep TMS 104 RCT System is a non-invasive treatment for mental health conditions that uses magnetic pulses to stimulate the brain.
  • ComponentsIncludes a stimulator, touchscreen interface, cooling system, and card reader 
  • TreatmentPatients wear a helmet with electromagnetic coils that deliver magnetic pulses to the brain 
  • PurposeTreats conditions like major depressive disorder (MDD), obsessive-compulsive disorder (OCD), and smoking cessation 
  • SafetyWell-tolerated treatment with a favorable safety profile 
  • EffectivenessResearch shows that Deep TMS is effective in alleviating symptoms 
  • InsuranceMany insurance providers offer coverage for Deep TMS 
  • Ease of useDesigned to be easy to use for operators and comfortable for patients 
  • Sham-enabledVersions are available for randomized controlled clinical research 
 
Features
The BrainsWay Deep TMS 104 RCT System has several features, including:
  • H-CoilsThe system's patented H-Coils are flexible and embedded in a cushioned, cooled helmet that fits each patient's head. The H-Coils provide deeper and broader stimulation than traditional TMS coils, which are rigid and shaped like a figure-8. 
  • Touchscreen interfaceThe system has an intuitive touchscreen interface. 
  • Cooling systemThe system has an efficient cooling system. 
  • Card readerThe system has a card reader that randomly selects sham or Deep TMS stimulation. 
  • Sham-enabled versionsSham-enabled versions are available for randomized controlled clinical research.
 

Click here to download Brochure 

WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare