NEUROSTIM-Transcranial Electrical Stimulator
$0.00
Shipped From Abroad
NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
DC output current – up to 2mA
Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).
The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.
Continuous monitoring of electrode impedance
It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect. Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).
Two modes of use: inpatient and outpatient
For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.
For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.
USB connection for advanced control
The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB. The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
- smulus current – up to 5 mA (30 V)
- smulaon duraon – up to 40 min
- smulus type:
- tDCS (transcranial direct current smulaon)
- tACS (transcranial alternang current smulaon)
- tRNS (transcranial random noise smulaon)
- tDCS-Sham (transcranial direct current smulaon + sham)
- tPCS (transcranial pulse current smulaon) custom waveform
- secure administrator mode to set up sessions
- operaon modes:
- stand-alone
- USB-controlled (smulaon by specified protocol; creaon and eding of smulaon protocols)
Specifications
- 1 channel transcranial smulator for unipolar (DC) and bipolar (AC) smulaon
- adjustable smulus current of 0 up to 5 mA with 25 µA increment
- adjustable smulaon duraon of 15 s to 40 min with 5 s increment
- 16 bit D/A conversion
- sampling rate:
tACS – 33 kHz
tRNS – 10 kHz
tDCS – 500 Hz
tPCS – 10 kHz - storage – 250 smulaon sessions
- power supply: from 9 V baery of 6LR61 or HR22 type or rechargeable batteries (up to 3 hours)
from USB of +5 V (galvanically isolated up to 4000 V)
Quick Comparison
Settings | NEUROSTIM-Transcranial Electrical Stimulator remove | BRAINSWAY Deep TMS H7 RCT Coil remove | Dolphin-MAX Transcranial Doppler Probe remove | Falcon-PRO Transcranial Doppler Probe remove | RESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker remove | BRAINSWAY Deep TMS H1 Coil remove |
---|---|---|---|---|---|---|
Name | NEUROSTIM-Transcranial Electrical Stimulator remove | BRAINSWAY Deep TMS H7 RCT Coil remove | Dolphin-MAX Transcranial Doppler Probe remove | Falcon-PRO Transcranial Doppler Probe remove | RESCUE LIFE 9 AED DEFIBRILLATOR with Temp, Spo2, Pacemaker remove | BRAINSWAY Deep TMS H1 Coil remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF1033560130187-33 | SF1033560130162-6 | SF1033560130142-2 | SF1033560130142-5 | SF10335601298-1 | SF1033560130162-4 |
Rating | ||||||
Price |
|
|
|
|
|
|
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description | Shipped From Abroad
NEUROSTIM is a Transcranial Electrical Stimulator (TES) designed for neuromodulation, neuroprotection, and rehabilitation. It delivers precise electrical stimulation to targeted brain areas, aiding in motor cortex mapping, neurological recovery, and cognitive enhancement. Ideal for neurologists, neurosurgeons, and rehabilitation specialists, NEUROSTIM ensures safe, effective, and customizable stimulation for both clinical and research applications. With its advanced technology and user-friendly interface, it enhances treatment precision and patient outcomes in neuroscience and neurorehabilitation.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H7 Coil stimulates the anterior cingulate cortex and the medial prefrontal cortex. Treatment is designed to regulate the CSTC circuit believed to be involved in the inhibition of impulsive behavior. A sham coil is integrated above the treatment coil. To the patient and operator, the helmet appears the same, pulses sound the same, and stimulation feels the same on the scalp.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Transcranial Doppler machine with an integrated rechargeable battery. The Dolphin/MAX is the ideal portable TCD system for measurements of cerebral blood flow in Neurology, ICU, and Neurosurgery settings
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
State-of-the-Art technology to measure Segmental Blood Pressures, ABI, TBI, Doppler, PVR, PPG and stress testing. Falcon advanced EMR and PACS capabilities and reporting options are designed for medical centers and private clinics alike. Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
The H1 Coil stimulates the bilateral prefrontal cortex, with a preference for the left dorsolateral prefrontal cortex. In addition to numerous published, double-blind, randomized controlled trials validating the efficacy of Deep TMS for depression, clinical data of over 1,000 patients in real practice settings has shown compelling results. Among patients who completed 30 sessions, approximately 4 out of 5 achieved a clinical response, and approximately 2 out of 3 achieved remission from depression.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | DC output current – up to 2mA
Neurostim is intended for the transcranial noninvasive stimulation with direct low current (up to 2 mA).
The current generates the electrical field changing the brain cortex excitability. Such brain impact has therapeutic effect in the treatment of different disorders including fibromyalgia, major depressive episode, addiction/craving, lower limb neuropathic pain and recovery of motor functions after stroke and brain injuries.
Continuous monitoring of electrode impedance
It is very important to keep the reliable skin-electrode contact during the whole stimulation procedure. Poor electrode contact due to improper electrode placement or dry-out can result in decreased therapeutic effect. Neurostim ensures continuous impedance monitoring. If the electrode impedance is too high, a notification will sound and the stimulation will be terminated (paused).
Two modes of use: inpatient and outpatient
For inpatient treatment Neurostim is supplied with pre-defined treatment protocols for most commonly used therapy. Just select the protocol for the particular patient from the list.
For outpatient treatment you should create a treatment course (up to 250 stimulation sessions). A patient will start the treatment sessions one by one. The completed session will be locked and cannot be used for the treatment.
USB connection for advanced control
The software can be used to control and adjust stimulator through USB. In this mode the stimulator is also powered through USB. The software is a simple way to manage the session list. You can add, remove, edit, import and export session, download user-defined waveform.
Features
Specifications
| The Brainsway Deep TMS H7 RCT Coil is a flexible coil used in transcranial magnetic stimulation (TMS) to treat obsessive-compulsive disorder (OCD) and other neuropsychiatric conditions:
Features
|
https://youtu.be/Id0Ma1_lEo0?si=-B5sGwSCDZOQi-ZO
Features of Dolphin TCD Machine | https://youtu.be/YSWvhSIS1ho?si=ZVl2aB_GXgSRotbP
Features of Falcon Physiologic Machine | Progetti Rescue Life 9 is designed for out-of-hospital and hospital use.
Lightweight, ergonomic, attractive and robust portable device. Rescue Life 9 provides complete monitoring of parameters like 12 channels ECG, HR, SpO2, NIBP, Temperature and EtCO2. Synchronized cardioversion and external pacemaker in fixed or demand mode. Three operating modes: manual, AED, Advisory. Capnography waveform. Auto-test mode verifies device functions, battery status and charge-discharge system with real-time data management and report printing. The IPX4 permits operations under adverse climatic situations.
Rescue Life 9 Technical Specification:
General requirements
• Dimension: 335x225x360 mm
• Weight: 6.5 kg with dual batteries
• Electrical: AC 100-240 VAC, 50/60 Hz
• Rechargeable Lithium-ion batteries: 15.0 V - 3.2 Ah
• Battery Operation Time:
>5 hours, with 1 battery
>10 hours with 2 batteries
• Charge Time: Max. 3 hours
• Capacity: 150 shocks with 1 battery or 300 shocks with 2 batteries at 230J fully charged
• Software: Voice and text multi-language
• Memory: Internal flash for ECG data, events and usage review
Defibrillation
• Waveform: Biphasic Truncated Exponential (BTE), HiCAP technology (Large storage capacitor)
• Impedance: Compensated, range 25-200 Ohm
• Charge time: 6 sec for 230 J with the battery fully charged
AED mode
• Energy: Fixed energy at 200 J
• Protocol: ERC 2015 CPR Guidelines with voice and text prompts
• Shockable rhythms: VF with amplitude > 0.15 mV and VT with rhythm >150 bpm
• Sensitivity: Shockable rhythm -VF > 95%, -VT > 75%
• Specificity: According to ERC 2015,
• Normal sinusoidal rhythm > 99%
• Asystole and other non-shockable rhythms > 99%
Manual mode
• Energy range: 1-230 J (from 1-10 J in 1 J steps; from 10 to 230 J in 10 J steps)
• Commands: Multifunction trim knob
• Charge and shock button in the front panel
• Operating mode: EC G «R» wave synchro or async mode
• Indicators: Battery and main led indicators
Display
• Type: High contrast TFT colour LCD 8” (800x600 dots)
• Information: ECG traces, SpO2, NIBP, EtCO2, TEMP, Heart Rate indicator, filters, alarms and the batteries status
• Display mode: Can select 3, 6, 12 ECG leads
Ecg monitoring
• Bandwidth:
0.05 - 120 Hz (-3 db) in diagnostic mode
0.6 - 40 Hz (-3 db) in monitoring mode
• CMRR: > 98 dbv Input impedance: > 50 Mohm
• Input:
Patient cable 5 leads (I, II, III, aVL, aVF, aVR, V) - standard
Patient cable 10 leads (I, II, III, aVL, aVF, aVR, V1…..V6) - optional
• Speed: 5, 10, 25, 50 mm/sec
• Filters: 50/60 Hz, EMG Filter, base line
• HR range: 20-300 bpm (~2%), digital readout on the display
• Alarm: HR max settable 250 bpm; HR min 20 bpm
SpO2 (only 55505-55512)
• SpO2 range: 0-100% HR range: 30-250 bpm
• Accuracy: 70-100% ~2% for adults with finger clip sensor
• Alarm: Adjustable min 50%
Temperature
• Probe type: YSI400 compatible
• Range: 0 to 50° C
• Resolution: ±0.1° C
Standard
• IEC 60601-2-4; IEC 60601-1; IEC 60601-1-2; IEC 63204, IEC 62366-1
• CE Mark EEC 93/42: Medical device, Class IIb
• Isolation: ECG type CF, Defibrillation type BF
• Waterproof: Class IP54
| The BrainsWay Deep TMS H1 Coil is a transcranial magnetic stimulation (TMS) device that's used to treat depression and other mental disorders:
Features
|
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |
Reviews
There are no reviews yet.