/ /

Non-Contact Tonometer

Ask for Price$0.00

Shipped From Abroad

NCT-100 air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF103356013027
Brands:: Vision Star

Description

Non-Contact Tonometer air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.

Product features of Non-Contact Tonometer:
NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of  x-y-z with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness.

Performance Features of Non-Contact Tonometer:
1. Auto 3-D positioning of x-y-z results in precise and reliable measurement.
2. Full-auto measurement for both right and left eye data without manual switch.
3. Easy to operate the tonometer with colour touch monitor.
4. Stable data of IOP through soft air measurement .
5. To compensate corneal thickness measurement of IOP.

Technical Specifications of Non-Contact Tonometer:

Intraocular pressure (IOP) measuring range 1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg)
Measuring system dual sensor system of light and pressure
Working distance ≥11mm
R/L automatic detection and display
Measuring result 10 times per eye; 3 times result printing per eye
Recording  build-in printer
Measuring mode auto/manual
Focus when luminous spot is in the focus frame, 2 modes can be chosen.

auto mode: auto intraocular pressure measurement

manual mode: when it’s good focus, the

frame will turn yellow into green, and click

to start the measurement

Error indication if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”
Safety limit button install measurement for minimum distance between head and patient
Safety functions the distance between air nozzle and cornea

is controlled in preset range(such as 11mm);

it will stop going forward when the cornea is

too closed to air head.

Movement range ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement 0~65mm with under jaw layer
Display mode 10.1-inch HDMI color LED touch monitor
Output port USB2.0
Working platform electric elevating platform
Weight 19.7kg
size 380 mm (L) x 460mm (W) x 505mm (H)
Power supply 220V/50HZ

Reviews

There are no reviews yet.

Be the first to review “Non-Contact Tonometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNon-Contact Tonometer removeStandiometer removeWalker removeSyringe Bulb removeDirty Linen Trolley removePedal Bin remove
NameNon-Contact Tonometer removeStandiometer removeWalker removeSyringe Bulb removeDirty Linen Trolley removePedal Bin remove
Image
SKUSF103356013027SF1033560084-219SF1033560084-223SF1033560084-205SF1033560084-226SF1033560084-201
Rating
Price

Ask for Price$0.00

$64.00

$15.00

$1.99

$76.00

$17.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
NCT-100 air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This portable stadiometer is simple to set up and easy to use. It is durable and lightweight all-plastic construction, disassembles quickly, pieces fold neatly into footplate for easy carrying
  • There's no wall fastening necessary and it may be positioned against a wall or completely free standing due to its large floor plate
  • The stadiometer measures from 8 inch – 82 inch and 20 cm – 210 cm with 0.125 in / 0.1 cm graduations visible on both sides of the height rod
  • This portable height measuring rod is lightweight and easily carried - ideal for any traveling medical professional
  • A window in the Stadiometer's headpiece allows for a clear view of the height reading
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Material: Aluminium
  • Age Group: Adult Walkers
  • Height: 37 Inch
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Brushed Steel Finish
  • 3L capacities
  • Gripped pedal
  • Easy clean plastic bucket
  • Lip for hiding excess bag
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content Non-Contact Tonometer air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes. Product features of Non-Contact Tonometer: NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of  x-y-z with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness. Performance Features of Non-Contact Tonometer: 1. Auto 3-D positioning of x-y-z results in precise and reliable measurement. 2. Full-auto measurement for both right and left eye data without manual switch. 3. Easy to operate the tonometer with colour touch monitor. 4. Stable data of IOP through soft air measurement . 5. To compensate corneal thickness measurement of IOP. Technical Specifications of Non-Contact Tonometer:
Intraocular pressure (IOP) measuring range 1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg)
Measuring system dual sensor system of light and pressure
Working distance ≥11mm
R/L automatic detection and display
Measuring result 10 times per eye; 3 times result printing per eye
Recording  build-in printer
Measuring mode auto/manual
Focus when luminous spot is in the focus frame, 2 modes can be chosen. auto mode: auto intraocular pressure measurement manual mode: when it’s good focus, the frame will turn yellow into green, and click to start the measurement
Error indication if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”
Safety limit button install measurement for minimum distance between head and patient
Safety functions the distance between air nozzle and cornea is controlled in preset range(such as 11mm); it will stop going forward when the cornea is too closed to air head.
Movement range ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement 0~65mm with under jaw layer
Display mode 10.1-inch HDMI color LED touch monitor
Output port USB2.0
Working platform electric elevating platform
Weight 19.7kg
size 380 mm (L) x 460mm (W) x 505mm (H)
Power supply 220V/50HZ
  • This portable stadiometer is simple to set up and easy to use. It is durable and lightweight all-plastic construction, disassembles quickly, pieces fold neatly into footplate for easy carrying
  • There's no wall fastening necessary and it may be positioned against a wall or completely free standing due to its large floor plate
  • The stadiometer measures from 8 inch – 82 inch and 20 cm – 210 cm with 0.125 in / 0.1 cm graduations visible on both sides of the height rod
  • This portable height measuring rod is lightweight and easily carried - ideal for any traveling medical professional
  • A window in the Stadiometer's headpiece allows for a clear view of the height reading
Material Aluminium
Age Group Adult Walkers
Height 37 Inch
Ear / Ulcer Bulb Syringes are ideal for irrigating smaller wounds and alleviating congestion. The syringes are available in several sizes to meet clinical requirements.
  • Disposable syringe for aspiration and irrigation
  • Ideal for suctioning a newborn's airway
  • Sterile
  • Bulb Aspirator Syringe. - Supplied in sealed pack - Sterile.
  • Latex Free Bulb aspirator Syringe - Essential part of any Whelping kit.
  • Quickly and hygienically removes fluids from mouth and throat of puppies & Kittens.
  • Nasal aspirator to clear nose in babies.
  • Can be used to wash ulcers.
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
  • Brushed Steel Finish
  • 3L capacities
  • Gripped pedal
  • Easy clean plastic bucket
  • Lip for hiding excess bag
Height 260mm 10.24inches
Width 170mm 6.69inches
Depth 225mm 8.86inches
Weight 0.63kg 1.39lb
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare