Shipped From Abroad

NCT-100 air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF103356013027
Brands:: Vision Star

Description

Non-Contact Tonometer air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.

Product features of Non-Contact Tonometer:
NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of  x-y-z with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness.

Performance Features of Non-Contact Tonometer:
1. Auto 3-D positioning of x-y-z results in precise and reliable measurement.
2. Full-auto measurement for both right and left eye data without manual switch.
3. Easy to operate the tonometer with colour touch monitor.
4. Stable data of IOP through soft air measurement .
5. To compensate corneal thickness measurement of IOP.

Technical Specifications of Non-Contact Tonometer:

Intraocular pressure (IOP) measuring range 1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg)
Measuring system dual sensor system of light and pressure
Working distance ≥11mm
R/L automatic detection and display
Measuring result 10 times per eye; 3 times result printing per eye
Recording  build-in printer
Measuring mode auto/manual
Focus when luminous spot is in the focus frame, 2 modes can be chosen.

auto mode: auto intraocular pressure measurement

manual mode: when it’s good focus, the

frame will turn yellow into green, and click

to start the measurement

Error indication if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”
Safety limit button install measurement for minimum distance between head and patient
Safety functions the distance between air nozzle and cornea

is controlled in preset range(such as 11mm);

it will stop going forward when the cornea is

too closed to air head.

Movement range ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement 0~65mm with under jaw layer
Display mode 10.1-inch HDMI color LED touch monitor
Output port USB2.0
Working platform electric elevating platform
Weight 19.7kg
size 380 mm (L) x 460mm (W) x 505mm (H)
Power supply 220V/50HZ

Reviews

There are no reviews yet.

Be the first to review “Non-Contact Tonometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNon-Contact Tonometer removeUrine Analyzer removeSyringe Needle Destroyer removeStandiometer removeNihon Kohden Neurofax 1200 Electroencephalogram (EEG) Machine removeSiare Morpheus M Anaesthetic Machine remove
NameNon-Contact Tonometer removeUrine Analyzer removeSyringe Needle Destroyer removeStandiometer removeNihon Kohden Neurofax 1200 Electroencephalogram (EEG) Machine removeSiare Morpheus M Anaesthetic Machine remove
ImageElectroencenphalogram (EEG) Machine
SKUSF103356013027SF1033560084-224SF1033560084-206SF1033560084-219SF1033560020-2SF1033560101-2
Rating
Price

Ask for Price$0.00

$540.00

$157.00

$64.00

Ask for Price$0.00

Ask for Price$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
NCT-100 air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Used for Clinical Diagnostics.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • This portable stadiometer is simple to set up and easy to use. It is durable and lightweight all-plastic construction, disassembles quickly, pieces fold neatly into footplate for easy carrying
  • There's no wall fastening necessary and it may be positioned against a wall or completely free standing due to its large floor plate
  • The stadiometer measures from 8 inch – 82 inch and 20 cm – 210 cm with 0.125 in / 0.1 cm graduations visible on both sides of the height rod
  • This portable height measuring rod is lightweight and easily carried - ideal for any traveling medical professional
  • A window in the Stadiometer's headpiece allows for a clear view of the height reading
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The high-acuity Neurofax EEG system is extremely intuitive. Its user-friendly software features a wide range of functions including record, playback, and quantitative data analysis. As a standard examination in neurology, electroencephalography is used in many scenarios – from routine diagnostics to critically ill patients, or neuromonitoring in the ICU. The Neurofax EEG system is built to cover all aspects of diagnostics, delivering innovative functionality, high signal quality, and durability to ensure efficiency – all while remaining simple to use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content Non-Contact Tonometer air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes. Product features of Non-Contact Tonometer: NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of  x-y-z with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness. Performance Features of Non-Contact Tonometer: 1. Auto 3-D positioning of x-y-z results in precise and reliable measurement. 2. Full-auto measurement for both right and left eye data without manual switch. 3. Easy to operate the tonometer with colour touch monitor. 4. Stable data of IOP through soft air measurement . 5. To compensate corneal thickness measurement of IOP. Technical Specifications of Non-Contact Tonometer:
Intraocular pressure (IOP) measuring range 1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg)
Measuring system dual sensor system of light and pressure
Working distance ≥11mm
R/L automatic detection and display
Measuring result 10 times per eye; 3 times result printing per eye
Recording  build-in printer
Measuring mode auto/manual
Focus when luminous spot is in the focus frame, 2 modes can be chosen. auto mode: auto intraocular pressure measurement manual mode: when it’s good focus, the frame will turn yellow into green, and click to start the measurement
Error indication if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”
Safety limit button install measurement for minimum distance between head and patient
Safety functions the distance between air nozzle and cornea is controlled in preset range(such as 11mm); it will stop going forward when the cornea is too closed to air head.
Movement range ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement 0~65mm with under jaw layer
Display mode 10.1-inch HDMI color LED touch monitor
Output port USB2.0
Working platform electric elevating platform
Weight 19.7kg
size 380 mm (L) x 460mm (W) x 505mm (H)
Power supply 220V/50HZ
Used for Clinical Diagnostics.
  • Test Method: Dry Strip color-developing method
  • Test Principle: Dual wavelength reflectance photometry
  • Light Source: Cold Lamp with high brightness and long lifetime
  • Test System: Color-indentify system with high sensitivity and repeatability
  • Wavelength: 520nm, 640nm, 660nm
  • Throughput: 120 Strips/Hour
  • Test Mode: Single and continuous test mode are selectable
  • Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
  • Waste Collection: Waste urine and waste strips can be collected automatically
  • Test Strip: Use GENIUS original strips only
  • Display: LCD with high brightness and resolution
  • Language: Customizable language software
  • Memory: Save 2000 samples results, and auto recover the results when power off during working
  • Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
  • Report format: Half quantitative and qualitative, report the color and turbidity is available
  • Result unit: SI unit and routine unit are selectable
  • Status Check: Auto-check the status during power on and off, auto-indentify the alarm
  • Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
  • Power: 100-240V, Auto adapt according to the input voltage
  • Consumption: ≤80VA
  • Quality System: Certified by TUV and CMD
Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle. Features:
  • Well built
  • Easy to maintain
  • Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
  • With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
  • Short Name: Needle destruction / Needle Destroyer
  • Working Noise: ≤50 decibel
  • Superheating Sanitization Temperature: 95 deg C
  • Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
  • Working Noise: ≤50 decibel
  • Dimensions: Approx. 38cm x 29cm x 28cm
  • Power: AC 110V or 220V
  • This portable stadiometer is simple to set up and easy to use. It is durable and lightweight all-plastic construction, disassembles quickly, pieces fold neatly into footplate for easy carrying
  • There's no wall fastening necessary and it may be positioned against a wall or completely free standing due to its large floor plate
  • The stadiometer measures from 8 inch – 82 inch and 20 cm – 210 cm with 0.125 in / 0.1 cm graduations visible on both sides of the height rod
  • This portable height measuring rod is lightweight and easily carried - ideal for any traveling medical professional
  • A window in the Stadiometer's headpiece allows for a clear view of the height reading
The high-acuity Neurofax EEG system is extremely intuitive. Its user-friendly software features a wide range of functions including record, playback, and quantitative data analysis. As a standard examination in neurology, electroencephalography is used in many scenarios – from routine diagnostics to critically ill patients, or neuromonitoring in the ICU. The Neurofax EEG system is built to cover all aspects of diagnostics, delivering innovative functionality, high signal quality, and durability to ensure efficiency – all while remaining simple to use. Features:
  • Polaris.com, a powerful data management system, supports the straightforward administration and organization of diagnostic data. Modern communication interfaces (HL7 and GDT/BDT) enable integration into hospital and practice information systems.
  • Digital Video Software allows synchronized digital video for EEG systems using webcam, professional HD camera, or picture-in-picture as per requirements.
  • EEG Mapping, offers amplitude with spectral and frequency online mapping during acquisition, even with single channels and montages.
  • Spike and Seizure Detection Software with a high sensitivity and a stunningly low false positive rate.
  • Polysmith* combines sleep analysis software with recording devices to provide quick and precise data analysis – for a complete PSG solution customized to individual needs.
  • EEG Trend Program converts EEG signals into clear trend graphs making them easy to interpret (aEEG, DSA, CSA, Power FFT).
  • Smart vital signs interface for holistic multimodality assessment of patient, with capability to pull up 8 channels from bedside monitors
  • Live View Panel offers intuitive real-time management of diverse neuromonitoring data from a centralized location.
  • Amplifier: high-quality amplifier with 38 to 256 channels realizes wide-band EEG recording from slow shift to fast ripple.
  • Brain function mapping system: a comprehensive and sophisticated system for brain function mapping reduces timeconsuming procedures by combining cortical stimulation, easy switch between stimulation and recording, and a brain function mapping report all in one place.
  • EEG scope: data reviewer that allows review of previous EEG while monitoring, acquiring, and opening up to 4 EEGs at the same time.
  • 3D voltage mapping: whole head maps offer a complete overview and better interpretation of the topography of EEG abnormalities.
  • Customizable Main Menu that allows registration of examination protocol buttons on the main menu. Each button has user-defined settings for an examination which can be adjusted for different examination conditions and methods
  • Note Window offers to save up to 1,000 sections of waveforms for comparison by dragging and dropping. Up to 100 copied waveforms can be registered as sample data for comparison with other patients or teaching purposes.
  • NeuroReport, which is integrated in all Nihon Kohden EEG systems, offers individually configured report templates, including adaptive auto text functions, for fast and simple reporting. It guarantees maximum flexibility and compatibility.
Technical Specifications: Routine EEG composition: Electroencephalograph: EEG-1200J/K PC unit: CC-120AJ/AK Electrode junction box: JE-921A Flash lamp assembly: LS-703A Photic stimulator control unit: LS-120AJ/AK Cart: KE-122A Stand: KC-001A LCD display: Local purchase EMU Composition: Electroencephalograph: EEG-1200J/K PC unit: CC-120AJ/AK 256 channel electrode junction box: JE-120A-256 Input box converter: QI-123A Mini flat junction box: JE-125AK Mini flat junction box: JE-226AK Mini flat junction box: JE-227AK Mini flat junction box: JE-228AK Flash lamp assembly: LS-703A Photic stimulator control unit: LS-120AJ/AK Cart with printer table: KD-029A Stand: KC-001A LCD display: Local purchase Extension unit: MS-120BK Switch box: PE-210AK Model Suffixes EEG-1200 has the following suffixies: J: 110-127 V AC operation K: 220-240 V AC operation  
Click Here To Download Catalogue
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       
The MORPHEUS M is an anaesthesia machine and it can be used on adult, children and newborn patients. The MORPHEUS M is suitable for administration of Oxygen – Air – Nitrous Oxide – Halothane – Enflurane – Isoflurane – Sevoflurane – Desflurane mixtures. Features:
  • Mechanic gas mixing system
  • Electronic lung ventilator with 12” TFT colour display
  • Valves group: open, semi-closed, closed, heated, with soda lime absorber (1,5 Kg)
  • SIARETEX rapid connection device, Selectatec compatible for 2 vaporizers
  • Gas supply group
  • Ventilation modalities: APCV-PCV; APCV-TV; PSV; APNEA BACK-UP; VC-VAC; VC-VAC BABY; SIMV+PS (volumetric); SPONT; MANUAL.
  • Measured parameters: PAW; PEEP; Vte; ExpMV; Rate; I:E; FiO2, Pmax; Pmean; Pause; Vti; FLOWi; FLOWe; Tinsp; Tesp; Tpause; Cs; Ri
  • Displayed ventilation curves: Paw, Flow, Volume, Loop (Volume/Paw ; Volume/Flow)
  • Adjustable parameters: – O2 built-in Mixer device from 21% to 99% – I:E Adjustable Ratio: 1:1-1:2-1:3-1:4-2:1-3:1 – Inspiratory Flow – PEEP – Breathing Rate – Minute Volume; – Tidal Volume – Inspiratory Pressure Limit – Inspiratory Pause – Inspiratory Time – Trigger
  • Mechanic flowmeter module: 3-flow mechanical flow meter (O2 – N2O – AIR) with 5 flow meters for low flows. Equipped with safety systems (MIX-LIFE, CUT-OFF, flow meter protection valve).
  • Breathing system: The breathing system of Morpheus guarantees to the user an absolute flexibility and easy handling thanks to the noble construction materials employed. The valves group can be drawn-up and it’s totally autoclavable at 121°C and all its parts are manually dismountable, with no need of special tools.The breathing system is made of; Calibrated APL valve, Fresh gas collecting bag, O2 cell for reading of FiO2, Removable 1 kg soda lime canister, Manually inspectionable bellows jar, Safety valve for ambience air suction in case of fresh gas failure, Flow transducer inside the group located on the expiratory line.
Optional accessories 11054 AIRPAK 54 stand-alone medical air compressor 100150/IDF Isoflurane Vaporizer 100148/IDF Fluo-Halotane Vaporizer 100145/IDF Sevoflurane Vaporizer 100151/IDF Desflurane Vaporizer A57.049-800601 gas analysis module (5 AA – CO2 – N2O – O2 – MAC) ric.auto  
Click Here To Download Catalogue
                              )
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare