/ /

Non-Contact Tonometer

Ask for Price$0.00

Shipped From Abroad

NCT-100 air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF103356013027
Brands:: Vision Star

Description

Non-Contact Tonometer air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.

Product features of Non-Contact Tonometer:
NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of  x-y-z with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness.

Performance Features of Non-Contact Tonometer:
1. Auto 3-D positioning of x-y-z results in precise and reliable measurement.
2. Full-auto measurement for both right and left eye data without manual switch.
3. Easy to operate the tonometer with colour touch monitor.
4. Stable data of IOP through soft air measurement .
5. To compensate corneal thickness measurement of IOP.

Technical Specifications of Non-Contact Tonometer:

Intraocular pressure (IOP) measuring range 1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg)
Measuring system dual sensor system of light and pressure
Working distance ≥11mm
R/L automatic detection and display
Measuring result 10 times per eye; 3 times result printing per eye
Recording  build-in printer
Measuring mode auto/manual
Focus when luminous spot is in the focus frame, 2 modes can be chosen.

auto mode: auto intraocular pressure measurement

manual mode: when it’s good focus, the

frame will turn yellow into green, and click

to start the measurement

Error indication if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”
Safety limit button install measurement for minimum distance between head and patient
Safety functions the distance between air nozzle and cornea

is controlled in preset range(such as 11mm);

it will stop going forward when the cornea is

too closed to air head.

Movement range ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement 0~65mm with under jaw layer
Display mode 10.1-inch HDMI color LED touch monitor
Output port USB2.0
Working platform electric elevating platform
Weight 19.7kg
size 380 mm (L) x 460mm (W) x 505mm (H)
Power supply 220V/50HZ

Reviews

There are no reviews yet.

Be the first to review “Non-Contact Tonometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsNon-Contact Tonometer removeUrine Analyzer removeNihon Kohden Neurofax 1200 Electroencephalogram (EEG) Machine removeOPTIKA B-382PL-ALC Binocular Brightfeld Microscope removeWash Hand Bowl with Stand removeDirty Linen Trolley remove
NameNon-Contact Tonometer removeUrine Analyzer removeNihon Kohden Neurofax 1200 Electroencephalogram (EEG) Machine removeOPTIKA B-382PL-ALC Binocular Brightfeld Microscope removeWash Hand Bowl with Stand removeDirty Linen Trolley remove
ImageElectroencenphalogram (EEG) MachineOPTIKA B-382PL-ALC Binocular Brightfeld Microscope
SKUSF103356013027SF1033560084-224SF1033560020-2SF1033560098-13SF1033560084-246SF1033560084-226
Rating
Price

Ask for Price$0.00

$540.00

Ask for Price$0.00

Ask for Price$0.00

$36.00

$76.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
NCT-100 air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Used for Clinical Diagnostics.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad The high-acuity Neurofax EEG system is extremely intuitive. Its user-friendly software features a wide range of functions including record, playback, and quantitative data analysis. As a standard examination in neurology, electroencephalography is used in many scenarios – from routine diagnostics to critically ill patients, or neuromonitoring in the ICU. The Neurofax EEG system is built to cover all aspects of diagnostics, delivering innovative functionality, high signal quality, and durability to ensure efficiency – all while remaining simple to use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The OPTIKA B-380 is an educational and laboratory microscope for routine applications. Dye-cast frame, with high stability and ergonomy, for transmitted light observation. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Product name Wash-hand stand
Model BC316-2
Size 660*320*810mm
Bowl qty double
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content Non-Contact Tonometer air puff tonometer is a non contact tonometry machine for intraocular pressure (IOP) test. This machine is simple and easy to operate, and you can get test results within 10 seconds. Contactless measurement will reduce injuries or infections on eyes. Product features of Non-Contact Tonometer: NCT-100 air puff non-contact tonometer utilizes image control and feature recognition for auto 3-D positioning of  x-y-z with reliable judgment and measurement results, and easy to operate. The air puff non-contact tonometer can be used to measure intraocular pressure (IOP) and corneal thickness. Performance Features of Non-Contact Tonometer: 1. Auto 3-D positioning of x-y-z results in precise and reliable measurement. 2. Full-auto measurement for both right and left eye data without manual switch. 3. Easy to operate the tonometer with colour touch monitor. 4. Stable data of IOP through soft air measurement . 5. To compensate corneal thickness measurement of IOP. Technical Specifications of Non-Contact Tonometer:
Intraocular pressure (IOP) measuring range 1mmHg~30mmHg /1mmHg~60mmHg ( precision of 1mmHg)
Measuring system dual sensor system of light and pressure
Working distance ≥11mm
R/L automatic detection and display
Measuring result 10 times per eye; 3 times result printing per eye
Recording  build-in printer
Measuring mode auto/manual
Focus when luminous spot is in the focus frame, 2 modes can be chosen. auto mode: auto intraocular pressure measurement manual mode: when it’s good focus, the frame will turn yellow into green, and click to start the measurement
Error indication if the measurement signal is weak, the IOP will be enclosed by ( ), or display “ERR ”
Safety limit button install measurement for minimum distance between head and patient
Safety functions the distance between air nozzle and cornea is controlled in preset range(such as 11mm); it will stop going forward when the cornea is too closed to air head.
Movement range ≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement 0~65mm with under jaw layer
Display mode 10.1-inch HDMI color LED touch monitor
Output port USB2.0
Working platform electric elevating platform
Weight 19.7kg
size 380 mm (L) x 460mm (W) x 505mm (H)
Power supply 220V/50HZ
Used for Clinical Diagnostics.
  • Test Method: Dry Strip color-developing method
  • Test Principle: Dual wavelength reflectance photometry
  • Light Source: Cold Lamp with high brightness and long lifetime
  • Test System: Color-indentify system with high sensitivity and repeatability
  • Wavelength: 520nm, 640nm, 660nm
  • Throughput: 120 Strips/Hour
  • Test Mode: Single and continuous test mode are selectable
  • Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
  • Waste Collection: Waste urine and waste strips can be collected automatically
  • Test Strip: Use GENIUS original strips only
  • Display: LCD with high brightness and resolution
  • Language: Customizable language software
  • Memory: Save 2000 samples results, and auto recover the results when power off during working
  • Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
  • Report format: Half quantitative and qualitative, report the color and turbidity is available
  • Result unit: SI unit and routine unit are selectable
  • Status Check: Auto-check the status during power on and off, auto-indentify the alarm
  • Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
  • Power: 100-240V, Auto adapt according to the input voltage
  • Consumption: ≤80VA
  • Quality System: Certified by TUV and CMD
The high-acuity Neurofax EEG system is extremely intuitive. Its user-friendly software features a wide range of functions including record, playback, and quantitative data analysis. As a standard examination in neurology, electroencephalography is used in many scenarios – from routine diagnostics to critically ill patients, or neuromonitoring in the ICU. The Neurofax EEG system is built to cover all aspects of diagnostics, delivering innovative functionality, high signal quality, and durability to ensure efficiency – all while remaining simple to use. Features:
  • Polaris.com, a powerful data management system, supports the straightforward administration and organization of diagnostic data. Modern communication interfaces (HL7 and GDT/BDT) enable integration into hospital and practice information systems.
  • Digital Video Software allows synchronized digital video for EEG systems using webcam, professional HD camera, or picture-in-picture as per requirements.
  • EEG Mapping, offers amplitude with spectral and frequency online mapping during acquisition, even with single channels and montages.
  • Spike and Seizure Detection Software with a high sensitivity and a stunningly low false positive rate.
  • Polysmith* combines sleep analysis software with recording devices to provide quick and precise data analysis – for a complete PSG solution customized to individual needs.
  • EEG Trend Program converts EEG signals into clear trend graphs making them easy to interpret (aEEG, DSA, CSA, Power FFT).
  • Smart vital signs interface for holistic multimodality assessment of patient, with capability to pull up 8 channels from bedside monitors
  • Live View Panel offers intuitive real-time management of diverse neuromonitoring data from a centralized location.
  • Amplifier: high-quality amplifier with 38 to 256 channels realizes wide-band EEG recording from slow shift to fast ripple.
  • Brain function mapping system: a comprehensive and sophisticated system for brain function mapping reduces timeconsuming procedures by combining cortical stimulation, easy switch between stimulation and recording, and a brain function mapping report all in one place.
  • EEG scope: data reviewer that allows review of previous EEG while monitoring, acquiring, and opening up to 4 EEGs at the same time.
  • 3D voltage mapping: whole head maps offer a complete overview and better interpretation of the topography of EEG abnormalities.
  • Customizable Main Menu that allows registration of examination protocol buttons on the main menu. Each button has user-defined settings for an examination which can be adjusted for different examination conditions and methods
  • Note Window offers to save up to 1,000 sections of waveforms for comparison by dragging and dropping. Up to 100 copied waveforms can be registered as sample data for comparison with other patients or teaching purposes.
  • NeuroReport, which is integrated in all Nihon Kohden EEG systems, offers individually configured report templates, including adaptive auto text functions, for fast and simple reporting. It guarantees maximum flexibility and compatibility.
Technical Specifications: Routine EEG composition: Electroencephalograph: EEG-1200J/K PC unit: CC-120AJ/AK Electrode junction box: JE-921A Flash lamp assembly: LS-703A Photic stimulator control unit: LS-120AJ/AK Cart: KE-122A Stand: KC-001A LCD display: Local purchase EMU Composition: Electroencephalograph: EEG-1200J/K PC unit: CC-120AJ/AK 256 channel electrode junction box: JE-120A-256 Input box converter: QI-123A Mini flat junction box: JE-125AK Mini flat junction box: JE-226AK Mini flat junction box: JE-227AK Mini flat junction box: JE-228AK Flash lamp assembly: LS-703A Photic stimulator control unit: LS-120AJ/AK Cart with printer table: KD-029A Stand: KC-001A LCD display: Local purchase Extension unit: MS-120BK Switch box: PE-210AK Model Suffixes EEG-1200 has the following suffixies: J: 110-127 V AC operation K: 220-240 V AC operation  
Click Here To Download Catalogue
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                       
Observation mode: Brightfield. Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged). Interpupillary distance: Adjustable between 48 and 75 mm. Dioptric adjustment: On the left eyepiece tube. Eyepieces: WF10x/20 mm, high eye-point and secured by screw. Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings. Objectives: N-PLAN 4x/0.10 N-PLAN 10x/0.25 N-PLAN 40x/0.65 N-PLAN 100x/1.25 (Oil/Water) All with anti-fungus treatment. Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range. Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable. Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply.  
Click Here To Download Catalogue
Product name Wash-hand stand
Model BC316-2
Size 660*320*810mm
Bowl qty double
No of Wheel 4
Usage Hospital
Cloth Material Synthetic
Pole Material Aluminium / SS
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare