Octane Meter PE-7300
$0.00
Shipped From Abroad
Purpose:
Octane meter is intended for determination of Research Number (RON) and Motor Octane Number (MON) of automobile petrol and cetane number of diesel fuels during the operational check over field and laboratory conditions.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Purpose:
Octane meter is intended for determination of Research Number (RON) and Motor Octane Number (MON) of automobile petrol and cetane number of diesel fuels during the operational check over field and laboratory conditions.
Range of application:
– testing laboratories of the petroleum refineries and petroleum storage deports for the control of stability of technological processes;
– agencies carrying out petroleum products quality audit for conformity to requirements of national standards;
– research laboratories
Technical specifications:
Types of controllable fuel – Automobile petrol and Diesel fuel
– Octane number range – 66?98
– Cetane number range – 30?70
 Measurement error:
– octane number, no more – ±1.0
– cetane number, no more – ±1.0
Measurement time, no more than, sec – 10
Power supply:
– battery – model 6F22, voltage9V
– adapter – DC 12V/25mA
Continuous running time, hours – 10
Operating conditions:
– ambient temperature, °C – 10? +35
– relative humidity, % @35°C – 95
– atmospheric pressure, mm Hg – 630?800
Overall dimensions:
– electronic block, WxLxH, mm, no more than – 76x210x23
– sensor, DiaxH, mm, no more than – 48×110
– total weight, kg, no more than – 1.2
Including:
– electronic block, kg, no more than – 0.8
– sensor, kg, no more than – 0.3
Mean Time Between Failures, not less than, hours – 1000
Review(1)
Quick Comparison
Settings | Octane Meter PE-7300 remove | Alcohol Pad Per Pack remove | Plastic Urine Container Per Pack remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Sugentech Inclix (POCT) Immunoassay Analyzer remove | Eppendorf Pipette Tip 20ul Per Pack remove | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Octane Meter PE-7300 remove | Alcohol Pad Per Pack remove | Plastic Urine Container Per Pack remove | AGD Erma EL-120 ELectrolyte Analyzer remove | Sugentech Inclix (POCT) Immunoassay Analyzer remove | Eppendorf Pipette Tip 20ul Per Pack remove | ||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||
SKU | SF1033560107 | SF1033560084-64 | SF1033560084-106 | SF1033560084-125 | SF1033560084-89 | SF1033560084-136 | ||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||
Price |
| $4.25 | $8.20 | $1,320.00 |
|
| ||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Purpose:
Octane meter is intended for determination of Research Number (RON) and Motor Octane Number (MON) of automobile petrol and cetane number of diesel fuels during the operational check over field and laboratory conditions.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| Shipped From Abroad
| In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| ||||||||||||||||||||||||||||
Content | Purpose: Octane meter is intended for determination of Research Number (RON) and Motor Octane Number (MON) of automobile petrol and cetane number of diesel fuels during the operational check over field and laboratory conditions. Range of application: - testing laboratories of the petroleum refineries and petroleum storage deports for the control of stability of technological processes; - agencies carrying out petroleum products quality audit for conformity to requirements of national standards; - research laboratories Technical specifications: Types of controllable fuel – Automobile petrol and Diesel fuel - Octane number range - 66?98 - Cetane number range - 30?70  Measurement error: - octane number, no more – ±1.0 - cetane number, no more – ±1.0 Measurement time, no more than, sec – 10 Power supply: - battery – model 6F22, voltage9V - adapter – DC 12V/25mA Continuous running time, hours – 10 Operating conditions: - ambient temperature, °C - 10? +35 - relative humidity, % @35°C – 95 - atmospheric pressure, mm Hg – 630?800 Overall dimensions: - electronic block, WxLxH, mm, no more than – 76x210x23 - sensor, DiaxH, mm, no more than – 48x110 - total weight, kg, no more than – 1.2 Including: - electronic block, kg, no more than – 0.8 - sensor, kg, no more than – 0.3 Mean Time Between Failures, not less than, hours - 1000 | Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use.
Size and packing of Medical Alcohol pad:
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
|
| Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
Click Here To Download Catalogue | INCLIXâ„¢ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIXâ„¢ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system.
Features:
• Good accuracy owning to superior CMOS sensor & our own Algorism
• 10,000 test results data storage
• Instrument Check by Reference Kit
• Remote Support available (when connected via Internet)
• Built-in Thermal Printer and Barcode Scanner
• Data export to USB(PDF, Excel), Email and LIS
• Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃
• Shelf Life of Test Cassette & Buffer : 24 months
Click Here To Download Catalogue |
| ||||||||||||||||||||||||||||