Octane Meter PE-7300

$0.00

Shipped From Abroad

Purpose:
Octane meter is intended for determination of Research Number (RON) and Motor Octane Number (MON) of automobile petrol and cetane number of diesel fuels during the operational check over field and laboratory conditions.

Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.

SF1033560107
Brands:: ECROSKHIM

Description

Purpose:
Octane meter is intended for determination of Research Number (RON) and Motor Octane Number (MON) of automobile petrol and cetane number of diesel fuels during the operational check over field and laboratory conditions.

Range of application:
– testing laboratories of the petroleum refineries and petroleum storage deports for the control of stability of technological processes;
– agencies carrying out petroleum products quality audit for conformity to requirements of national standards;
– research laboratories

Technical specifications:

Types of controllable fuel – Automobile petrol and Diesel fuel
– Octane number range – 66?98
– Cetane number range – 30?70

 Measurement error:
– octane number, no more – ±1.0

– cetane number, no more – ±1.0

Measurement time, no more than, sec – 10

Power supply:
– battery – model 6F22, voltage9V

– adapter – DC 12V/25mA

Continuous running time, hours – 10

Operating conditions:
– ambient temperature, °C – 10? +35
– relative humidity, % @35°C – 95
– atmospheric pressure, mm Hg – 630?800

Overall dimensions:
– electronic block, WxLxH, mm, no more than – 76x210x23

– sensor, DiaxH, mm, no more than – 48×110
– total weight, kg, no more than – 1.2

 

Including:
– electronic block, kg, no more than – 0.8
– sensor, kg, no more than – 0.3

 

Mean Time Between Failures, not less than, hours – 1000

Review(1)

4.00 average based on 1 ratings.
  1. Al sadara company

    I would like to to open a market for your product in Yemen

Add a review

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsOctane Meter PE-7300 removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeiSED Fully Automated ESR Analyzer removeNikon SMZ745 Stereoscopic Microscope removeIISM VPism-C (Compact Type) Vein Probe removeDiscover 14 Panel Cup with Adulterants Per Pack remove
NameOctane Meter PE-7300 removeTest Strip for ApexBio HemoSmart Gold Hemoglobin Meter removeiSED Fully Automated ESR Analyzer removeNikon SMZ745 Stereoscopic Microscope removeIISM VPism-C (Compact Type) Vein Probe removeDiscover 14 Panel Cup with Adulterants Per Pack remove
ImageNikon SMZ745 Stereoscopic MicroscopeIISM VPism-C (Compact Type) Vein ProbeDrug Test Cup
SKUSF1033560107SF1033560084-30SF1033560084-129SF1033560084-49SF1033560090-1SF1033560084-28
Rating
Price

$0.00

$9.50

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Purpose: Octane meter is intended for determination of Research Number (RON) and Motor Octane Number (MON) of automobile petrol and cetane number of diesel fuels during the operational check over field and laboratory conditions. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Twenty Five (25) Test Strip per Pack

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745T trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content

Purpose: Octane meter is intended for determination of Research Number (RON) and Motor Octane Number (MON) of automobile petrol and cetane number of diesel fuels during the operational check over field and laboratory conditions.

Range of application: - testing laboratories of the petroleum refineries and petroleum storage deports for the control of stability of technological processes; - agencies carrying out petroleum products quality audit for conformity to requirements of national standards; - research laboratories

Technical specifications:

Types of controllable fuel – Automobile petrol and Diesel fuel - Octane number range - 66?98 - Cetane number range - 30?70

 Measurement error: - octane number, no more – ±1.0 - cetane number, no more – ±1.0

Measurement time, no more than, sec – 10

Power supply: - battery – model 6F22, voltage9V - adapter – DC 12V/25mA

Continuous running time, hours – 10

Operating conditions: - ambient temperature, °C - 10? +35 - relative humidity, % @35°C – 95 - atmospheric pressure, mm Hg – 630?800

Overall dimensions: - electronic block, WxLxH, mm, no more than – 76x210x23 - sensor, DiaxH, mm, no more than – 48x110 - total weight, kg, no more than – 1.2   Including: - electronic block, kg, no more than – 0.8 - sensor, kg, no more than – 0.3   Mean Time Between Failures, not less than, hours - 1000
Twenty Five (25) Test Strip per PackThe technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745 trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Features:
  • Trinocular optical head for monitoring and digital imaging
  • Impressive 7.5x zoom magnification
  • 115 mm working distance
  • Maximum ergonomics
  • Rugged, durable design suits a variety of applications and environments
Technical Specifications:
Optical system Greenough optical system
Total magnification 3.35-300x, depending on eyepiece and auxiliary objective used
Vertical tube Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD
Eyepiece tube Fixed type
Eyepiece inclination 45°
Interpupillary distance adjustment 52-75 mm
Eyepieces (with diopter adjustment) C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7)
Zooming ratio 7.5:1 (approx.)
Zooming range 0.67-5x
Auxiliary objectives G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm)
Working distance 115 mm
     
 
 
The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. This handheld, portable device is lightweight and includes the touchscreen and camera with attached clip. The camera can be removed and handled by hand, or can clip to the touchscreen unit for a hands-free experience. The back of the device also has a kickstand, so that physicians can stand the device on its own. The VPism-C can also be mounted to an armrest, if a patient needs to be stationary, or attached to a SLism-F Specialized Light Source for patients with deeper vessels. This device can be a vital tool in providing accurate placement of injections or other vascular treatments, such as for varicose veins. The infrared video shows the location of the veins and capillaries in real time, as well as save images for further discussion or diagnosis. For patients who have difficult-to-find veins, this device will save them from incorrect or painful injection sites. Features: Probe Target: Subcutaneous blood vessels of various patients (including capillaries) Probe Method: Non-invasive infrared technology Probe Depth: Within 10 mm under the skin Magnification Function: Up to 1X, 2X and 4X Automatic Adjustment Function: Adjusts the brightness automatically based on the targeted vein Specialized Light Function: Shows the veins more clearly by using the specialized light source Operation Method: Easy to operate with touchscreen Internal Battery Support: Continuous running time: 1.5 hours Warranty: 1 year
Click Here To Download Catalogue
 
All-in-One Design
FDA 510(K) & CLIA Waived Up to 99% accuracy rate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 17 substances with adulterants or 18 without adulterants Adulterants available
 
 
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Model

Advanced, Advanced Plus, Basic, Smart

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare