PCR cabinet are designed to reduce the risk of contamination while performing Polymerase Chain Reaction (PCR) experiments, it direct HEPA-filtered air downward over the work area to provide ISO Class 5 (formerly Class 100) conditions and protect your work during preparatory procedures and amplifications.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
Variable digital timer that provides UV light exposure continuously or in user-selected increments of 15, 30, 60,120 till 999 minutes to deactivate DNA and RNA contaminants.
Intuitive and easy-to-use microprocessor controller with LCD display, graphical and digital display of all the operating status of each function, such as filter life, UV life etc.
Ergonomic control panel location, centered and angled down for an easy reach & viewing.
The non-direct light source design can effectively relieve the operator’s visual fatigue under the condition of ensuring the illumination.
Different sizes available from 2 feet to 6 feet, benchtop use or mounted on a mobile base.
Brushed stainless steel work surface is for easy cleaning.
Safety Performance:
Audio and visual alarm on filter life, UV life etc.
Front sliding sash interlock with fan and UV lamp.
Front sash and side windows are made of UV-resistant tempered glass.
The host and sockets have independent capacitors to prevent current overload.
Humanized design:
Standard shelves with IV bar.
Memory function in case of power-failure.
HEPA filter and UV life indicators facilitate a timely replacem ent plan.
Two sides glass windows installed for easy experiment observation.
Easy-to-change pre-filter installed could extend the HEPA filter’s lifetime.
Equipped with temperature sensor to show the real temperature during operation.
Waterproof socket provide convenience for small instruments to be used in the operating area.
PCR Cabinet Specifications:
Model
PCR-800
PCR-1100
PCR-1300
PCR-1600
PCR-1900
External Size (WxDxH)(mm)
710x680x1050 (Without Base Stand)
710x680x1670 (With Base Stand)
1050x710x1850
1320x710x1850
1625x710x1850
1930x710x1850
Internal Size (WxDxH)(mm)
610x590x625
950x615x625
1220x615x625
1525x615x625
1830x615x625
Work Surface Height
750mm
Control System
Microprocessor controller with LCD display, graphical and digital display of the operating status
Audio and visual alarm on filter and UV changing
Front sliding sash interlock with fan and UV lamp
HEPA filter and UV life indicators facilitate a timely replacement plan
Air Filtration System
Cleanness
ISO Class 5 (Formerly Class 100)
Airflow Velocity
0.2~0.5 m/s, speed adjustable
HEPA Filter
1 pcs, efficiency > 99.995% at particle size of 0.3 μm
Pre-Filter
1 pcs, made of washable polyester fiber
Partial Air Circulation
Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
Sound Emission
≤62dB(A)
Illuminating Lamp
LED Type, Illumination ≥900Lx
UV Decontamination System
1. With timing function from 0 to 999 minutes
2. Interlock with front sliding sash.
3. Emission of 253.7 nanometers for best sterilization effect.
10Wx2
20Wx1
30Wx1
30Wx1
20Wx2
Power Consumption
149W
155W
285W
285W
300W
External devices connected via power sockets are not included
Cabinet Structure
Main Body: Electro-Galvanized steel with antimicrobial powder coating
Work Zone: 304 Stainless steel, an angled front, rounded work surface front edge
Side Windows: 5 mm UV resistant tempered glass
Power Supply
AC220V ±10%, 50/60Hz, 1P
Standard Accessories
LED lamp; UV lampx2; Waterproof socket×2 (only 1 for PCR-800); Shelves with IV bar
Optional Accessories
Base stand(only PCR-800); Water tap, Gas tap, Height adjustable base stand
Net Weight
80kg(Without
base stand), 130kg (With base stand)
–
Gross Weight
115kg (Without base stand), 165kg (With base stand)
Shipped From Abroad
PCR cabinet are designed to reduce the risk of contamination while performing Polymerase Chain Reaction (PCR) experiments, it direct HEPA-filtered air downward over the work area to provide ISO Class 5 (formerly Class 100) conditions and protect your work during preparatory procedures and amplifications.
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stockLittle Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods.
Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR).
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Total Volume: 60mL.
Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
Made of premium PP material, it is durable for usage.
Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
PCR Cabinet Features:
Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
Variable digital timer that provides UV light exposure continuously or in user-selected increments of 15, 30, 60,120 till 999 minutes to deactivate DNA and RNA contaminants.
Intuitive and easy-to-use microprocessor controller with LCD display, graphical and digital display of all the operating status of each function, such as filter life, UV life etc.
Ergonomic control panel location, centered and angled down for an easy reach & viewing.
The non-direct light source design can effectively relieve the operator's visual fatigue under the condition of ensuring the illumination.
Different sizes available from 2 feet to 6 feet, benchtop use or mounted on a mobile base.
Brushed stainless steel work surface is for easy cleaning.
Safety Performance:
Audio and visual alarm on filter life, UV life etc.
Front sliding sash interlock with fan and UV lamp.
Front sash and side windows are made of UV-resistant tempered glass.
The host and sockets have independent capacitors to prevent current overload.
Humanized design:
Standard shelves with IV bar.
Memory function in case of power-failure.
HEPA filter and UV life indicators facilitate a timely replacem ent plan.
Two sides glass windows installed for easy experiment observation.
Easy-to-change pre-filter installed could extend the HEPA filter’s lifetime.
Equipped with temperature sensor to show the real temperature during operation.
Waterproof socket provide convenience for small instruments to be used in the operating area.
PCR Cabinet Specifications:
Model
PCR-800
PCR-1100
PCR-1300
PCR-1600
PCR-1900
External Size (WxDxH)(mm)
710x680x1050 (Without Base Stand)
710x680x1670 (With Base Stand)
1050x710x1850
1320x710x1850
1625x710x1850
1930x710x1850
Internal Size (WxDxH)(mm)
610x590x625
950x615x625
1220x615x625
1525x615x625
1830x615x625
Work Surface Height
750mm
Control System
Microprocessor controller with LCD display, graphical and digital display of the operating status
Audio and visual alarm on filter and UV changing
Front sliding sash interlock with fan and UV lamp
HEPA filter and UV life indicators facilitate a timely replacement plan
Air Filtration System
Cleanness
ISO Class 5 (Formerly Class 100)
Airflow Velocity
0.2~0.5 m/s, speed adjustable
HEPA Filter
1 pcs, efficiency > 99.995% at particle size of 0.3 μm
Pre-Filter
1 pcs, made of washable polyester fiber
Partial Air Circulation
Perforations at the back wall of the work zone which are designed to eliminate air turbulence and the possibility of dead air corners in the work zone.
Sound Emission
≤62dB(A)
Illuminating Lamp
LED Type, Illumination ≥900Lx
UV Decontamination System
1. With timing function from 0 to 999 minutes
2. Interlock with front sliding sash.
3. Emission of 253.7 nanometers for best sterilization effect.
10Wx2
20Wx1
30Wx1
30Wx1
20Wx2
Power Consumption
149W
155W
285W
285W
300W
External devices connected via power sockets are not included
Cabinet Structure
Main Body: Electro-Galvanized steel with antimicrobial powder coating
Work Zone: 304 Stainless steel, an angled front, rounded work surface front edge
Side Windows: 5 mm UV resistant tempered glass
Power Supply
AC220V ±10%, 50/60Hz, 1P
Standard Accessories
LED lamp; UV lampx2; Waterproof socket×2 (only 1 for PCR-800); Shelves with IV bar
Optional Accessories
Base stand(only PCR-800); Water tap, Gas tap, Height adjustable base stand
Net Weight
80kg(Without
base stand), 130kg (With base stand)
-
Gross Weight
115kg (Without base stand), 165kg (With base stand)
225kg
255kg
285kg
330kg
Shipping Size (W×D×H mm)
920x850x1190
1190x990x1325
1460x990x1325
1765x990x1325
2070x990x1325
Shipping Volume
0.93m3
1.56m3
1.92m3
2.3m3
2.7m3
Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods.
Features:
Indicator light indicates working state.
For 4~6 minutes rapidly sterilizing.
Sterilizing temperature and time can be preset.
Steam-water inner circulation system: no steam discharge, and the environment for sterilizing will be clean and dry.
Over temperature & over pressure auto-protection.
Safe protection of water lacking.
Exhaust the cool air automatically.
With three stainless steel sterilizing plates.
The chamber of the sterilizer is made of stainless steel.
Automatically shut off with beep reminding after sterilization.
Technical Specifications:
MODEL
MC-XB20J
MC-XB24J
Sterilizing chamber volume
20L(φ250×420 mm)
24L(φ250×520 mm)
Maximum working pressure
0.22Mpa
Maximum working temperature
134℃
Adjustment of temperature
105-134℃
Timer
0-60 min
Chamber temperature equal
≤ ± 1℃
Source power
1.5KW/AC 220V 50Hz (AC110V 60HZ)
Sterilizing plate
340×200×30 mm (3 piece)
400×200×30 mm (3 piece)
Dimension
480×480×384 mm
580×480×384 mm
Package dimension
700×580×500 mm
800×580×500 mm
G. W/N.W
44/40 kg
50/45 kg
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
Results in 20 Seconds
100µL sample drawn directly from primary EDTA tube
Fully automated, walk-away operation
Random access
Positive patient identification via internal barcode reader
Compatible with pediatric tube
Technical Specifications:
Principle of Measure:
Photometrical
Results:
“Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements:
500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
Made of premium PP material, it is durable for usage.
Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
Max. speed: 14,100 x g (14,500 rpm)
Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
Rotor can be autoclaved at 121°C for 20 minutes
Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
Eliminate costly repairs with the low maintenance drive
Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface.
Features:
Parameters: Na+,K+,Cl-, iCa++ / Li
It works on ISE principle
Sample Type: Whole blood, Serum, Plasma, Urine
Low reagent consumption
Sample requirement is only 90ul
60 samples per hour
Automatic two point calibration after 4hrs and one point calibration with each sample analysis
Air bubble detection
Track reagents consumption and provides alerts
For low reagent volume
Precision testing facility to get CV and SD
Trilevel Quality Control with LJ plots of last 30days
Reviews