Purpose:
The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Purpose:
The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing.
Technical specifications:
– Maximum heating temperature, °C – up to 370
– Power supply voltage from AC mains with frequency of 50Hz, V – 220±22
– Power consumption, no higher than, W – 400
– Instrument weight, kg – 6.8
– Service life, years at least – 5
Operation conditions:
– Air temperature, °C – 15?35
– Relative humidity, % – 30?90
– Overall dimensions (body), mm:
– Length, mm – 307
– Width, mm – 255
– Height, mm – 153
– Range of flash point determination, °C – 25-370
– Ignition device, type – oil
Complete set:
1. Pensky-Martens Closed Cup Flash Point Tester PE-TVZ- 1 pc.
2. Thermometer- 1pc.
3. Operation manual- 1 pc.
4. ASTM D93
5. Stowage box- 1 pc.
Quick Comparison
Settings | Pensky-Martens Closed Cup Flash Point Tester PE-TVZ remove | Eppendorf Pipette Tip 200ul Per Pack remove | Avalun LabPad Device remove | Zenithlab (IB-9025A) Laboratory Incubator remove | Plastic Urine Container Per Pack remove | Nikon SMZ745 Stereoscopic Microscope remove | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Pensky-Martens Closed Cup Flash Point Tester PE-TVZ remove | Eppendorf Pipette Tip 200ul Per Pack remove | Avalun LabPad Device remove | Zenithlab (IB-9025A) Laboratory Incubator remove | Plastic Urine Container Per Pack remove | Nikon SMZ745 Stereoscopic Microscope remove | ||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||
SKU | SF10335601078 | SF1033560084-137 | SF1033560084-65 | SF1033560084-109 | SF1033560084-106 | SF1033560084-49 | ||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||
Price |
|
|
| $350.00 | $8.20 |
| ||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||
Description | Shipped From Abroad
Purpose:
The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
| In stock Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745T trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | ||||||||||||||||||||||
Content | Purpose: The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing. Technical specifications: - Maximum heating temperature, °C - up to 370 - Power supply voltage from AC mains with frequency of 50Hz, V - 220±22 - Power consumption, no higher than, W - 400 - Instrument weight, kg – 6.8 - Service life, years at least – 5 Operation conditions: - Air temperature, °C - 15?35 - Relative humidity, % - 30?90 - Overall dimensions (body), mm: - Length, mm - 307 - Width, mm - 255 - Height, mm - 153 - Range of flash point determination, °C - 25-370 - Ignition device, type - oil Complete set: 1. Pensky-Martens Closed Cup Flash Point Tester PE-TVZ- 1 pc. 2. Thermometer- 1pc. 3. Operation manual- 1 pc. 4. ASTM D93 5. Stowage box- 1 pc. |
| The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | Features:
|
| Nikon SMZ745 Stereoscopic Microscope: Featuring a zoom magnification of 7.5X and a long working distance of 115mm, Nikon SMZ745 microscopes are well suited for both industrial and biomedical applications. The adoption of a new total reflection prism produces brighter images with higher contrast, and the anti-mold design allows the microscope to be used in environments where the temperature and humidity are high. The SMZ-745 trinocular model comes equipped with a microscope camera port and a built-in 0.55x c-mount adapter, permitting direct mounting of Nikon DS Series Digital Cameras.
Features:
| ||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.