Pensky-Martens Closed Cup Flash Point Tester PE-TVZ
$0.00
Shipped From Abroad
Purpose:
The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Purpose:
The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing.
Technical specifications:
– Maximum heating temperature, °C – up to 370
– Power supply voltage from AC mains with frequency of 50Hz, V – 220±22
– Power consumption, no higher than, W – 400
– Instrument weight, kg – 6.8
– Service life, years at least – 5
Operation conditions:
– Air temperature, °C – 15?35
– Relative humidity, % – 30?90
– Overall dimensions (body), mm:
– Length, mm – 307
– Width, mm – 255
– Height, mm – 153
– Range of flash point determination, °C – 25-370
– Ignition device, type – oil
Complete set:
1. Pensky-Martens Closed Cup Flash Point Tester PE-TVZ- 1 pc.
2. Thermometer- 1pc.
3. Operation manual- 1 pc.
4. ASTM D93
5. Stowage box- 1 pc.
Quick Comparison
Settings | Pensky-Martens Closed Cup Flash Point Tester PE-TVZ remove | Little Sister Table Top Autoclave remove | iSED Fully Automated ESR Analyzer remove | Avalun LabPad Device remove | Zenithlab (IB-9025A) Laboratory Incubator remove | Hawksley 1400 Haematocrit Centrifuge remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | Pensky-Martens Closed Cup Flash Point Tester PE-TVZ remove | Little Sister Table Top Autoclave remove | iSED Fully Automated ESR Analyzer remove | Avalun LabPad Device remove | Zenithlab (IB-9025A) Laboratory Incubator remove | Hawksley 1400 Haematocrit Centrifuge remove | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SKU | SF10335601078 | SF1033560084-46 | SF1033560084-129 | SF1033560084-65 | SF1033560084-109 | SF1033560084-118 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Price |
| $1,350.00 |
|
| $350.00 | $690.00 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
Purpose:
The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing.
Delivery & Availability:
Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Out stock Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
| In stock
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Content | Purpose: The flash point tester PE-TVZ is intended for usage as laboratory equipment to perform closed cup flash point determination of oil products according to method B EN ISO 2719: 2002 and ASTM D93 are considered for oil products testing. Technical specifications: - Maximum heating temperature, °C - up to 370 - Power supply voltage from AC mains with frequency of 50Hz, V - 220±22 - Power consumption, no higher than, W - 400 - Instrument weight, kg – 6.8 - Service life, years at least – 5 Operation conditions: - Air temperature, °C - 15?35 - Relative humidity, % - 30?90 - Overall dimensions (body), mm: - Length, mm - 307 - Width, mm - 255 - Height, mm - 153 - Range of flash point determination, °C - 25-370 - Ignition device, type - oil Complete set: 1. Pensky-Martens Closed Cup Flash Point Tester PE-TVZ- 1 pc. 2. Thermometer- 1pc. 3. Operation manual- 1 pc. 4. ASTM D93 5. Stowage box- 1 pc. | Little Sister Table Top Autoclave: This sterilizer is a table type in safety and auto controlled,which is designed for the unit of medical health, pharmacy, science and technology and mostly suitable for sterilizing of surgical,dental and eye instruments, glassware medicine, culture medium and biological dressing, food and other goods.
Features:
| The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr.
Features:
| The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
Click Here To Download Catalogue | Features:
| The Hawksley Haematospin 1400 Centrifuges are built in the UK and are made from durable and high-quality components. These centrifuges are ideal for veterinary laboratories and practices specifically designed to produce reliable and accurate results on blood and urine. One of the main features of this centrifuge is that it takes both 2ml microtubes and 75mm microhaematocrits. The classic design of these centrifuges is used worldwide with guaranteed support for all servicing and parts.
Technical specifications:
Click Here To Download Catalogue | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.