PHYSIODYN-Expert

$0.00

Shipped From Abroad

Professional electrotherapy and diagnostics for clinics, rehabilitation centers and physiotherapy practices

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130148-14
Brands:: PHYSIOMED

Description

General Features
  • Perfected operating guidance through combination of 7″ touchscreen and PHYSIOMED one-button operation
  • A comprehensive overview of the therapy parameters currently being used, including all therapy timers
  • Comprehensive list of indications with information on therapy, dosage suggestions, treatment images and intelligent filter functions by body region, desired therapy effect or alphabet for quick search of the desired treatment suggestion
  • Easy-to-use and extensive memory menu with treatment sequences and history function
  • Multifunctional intensity controller with intensity comfort swelling
  • Logical color coding of the stimulation current and vacuum application accessories for quick and safe assignment of the channels and the respective polarity
  • SD card slot for product updates

 

Features of electrical stimulation therapy
  • Two-channel electrotherapy with 21 current forms
  • Alternating and simultaneous stimulation
  • Spasticity treatment
  • Hand button as emergency stop switch or for intention exercises (optional)
  • Warnings when intensity is exceeded
  • Vacuum application with PHYSIOVAC-Expert (optional)

Medium frequency current forms:

  • IF (Classical Interference Current)
  • AMF (Amplitude Modulated Medium Frequency Current)
  • MT (Medium Frequency Muscle Stimulation)
  • KOTS (Russian Stimulation)

Low frequency current forms:

  • G (Galvanization)
  • GMC (Galvanization with Microcurrent)
  • DF (diadynamic current diphasé fixed)
  • MF (diadynamic current monophasé fixed)
  • CP (diadynamic current modulé en courtes périodes)
  • LP (Diadynamic current modulé en longues périodes)
  • UR (ultra-stimulation current according to Träbert)
  • HV (high voltage current)
  • TENS (Transcutaneous Electrical Nerve Stimulation)
  • MENS (Electrical Nerve Stimulation with Microcurrent)
  • IG 30 (impulse galvanization 30)
  • IG 50 (impulse galvanization 50)
  • FM (Frequency Modulated Current)
  • STOCH (Stochastic Current)
  • FaS (Faradic threshold current)
  • HVS (high voltage stimulation)
  • T/R (exponential current)

Diagnostics

  • Faradic excitability test
  • Medium frequency test according to Lange
  • Accommodation quotient
  • Rheobase/Chronaxis
  • I/T curve (with graphical representation of the curve)
  • I/T curve – quick test
Therapy information

Stimulation current therapy is an important component of electrotherapy. Stimulation currents are transmitted to the tissue to be treated via electrodes (plate electrodes, vacuum electrodes, adhesive electrodes). Depending on the type of current and the selection of parameters (i.e. pulse shape, pulse duration, pause time, frequency, intensity), stimulation currents can produce the following effects in the treatment area:

  • Musculoskeletal pain
  • Venous insufficiency/ulcers
  • Pressure ulcers
  • Strengthening the muscles
  • Iontophoresis

According to their origin and specific mode of action in the tissue, the following classification of the various stimulation currents can be made:

  • Medium frequency currents: these are alternating currents that are created by superimposing a base frequency (2-9.5 KHz) with a modulation frequency (0-250 Hz). With AMF current (amplitude-modulated medium frequency current) and medium frequency currents for muscle stimulation (MT and KOTS), this superimposition already takes place in the device. The pre-modulated current can therefore be delivered to the patient via just two electrodes. With classic interference current (IF), on the other hand, the two frequencies are only superimposed in the patient’s tissue, which is why four electrodes are always required for treatment. The high therapeutic effectiveness of medium frequency currents is due to their minimal skin irritation and pronounced depth effect, which means they are well accepted by the patient.
  • Pulse currents with frequencies below 1000 Hz are considered low frequency. The various low frequency currents DF, MF, CP, LP (diadynamic currents), UR (ultra stimulation current), HV (high voltage current), FaS (faradic threshold current), TENS (mono- or bidirectional rectangular pulses) and T/R (exponential current) can cover the entire above-mentioned application area. In contrast to medium frequency currents, certain low frequency currents can also be used to increase muscle strength.
  • Galvanic current (G) is a direct current that flows through the tissue with constant energy. Galvanic current is mainly used to stimulate blood circulation and reduce pain, as well as for iontophoresis (introducing a preparation using current).
Selected use cases

Electrotherapy has an extremely wide range of applications. It is ideal for treating, among other things:

  • Osteoarthritis (knee joint)
  • CRPS Stage I and II
  • Epicondylitis
  • Radicular syndrome
  • Spasticity treatment according to Hufschmidt/Jantsch
  • Acceleration trauma
  • Chondropathia patellae
  • Joint effusion
  • Pain syndrome, postoperative
  • Ankylosing spondylitis

Reviews

There are no reviews yet.

Be the first to review “PHYSIODYN-Expert”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPHYSIODYN-Expert removePolysorb Walker/Runner Insole removeRX Arch Cushions Insole removeDeep Vein Thrombosis DVT-7700 removeRX Orthotic Arch Insole removeAsco LCD Based Cervical Traction Machine remove
NamePHYSIODYN-Expert removePolysorb Walker/Runner Insole removeRX Arch Cushions Insole removeDeep Vein Thrombosis DVT-7700 removeRX Orthotic Arch Insole removeAsco LCD Based Cervical Traction Machine remove
ImageDVT pump
SKUSF1033560130148-14SF1033560130135-4SF1033560130135-10SF1033560084-290SF1033560130135-11SF1033560092
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Professional electrotherapy and diagnostics for clinics, rehabilitation centers and physiotherapy practices
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Cradles your feet with targeted cushioning that improves your athletic performance and prolongs the life of your shoes. Ideal for walking, running, training and sports.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Soothes tired feet and sore arches. Improves body alignment. Absorbs shock and reduces friction that can cause blisters.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock DVT-7700 MAIN with HOSE and Accessories (Disposable sleeve thigh(M), Disposable sleeve calf(M), Disposable sleeve foot, and Tube (pair)) - Deep vein thrombosis (DVT) happens when a blood clot forms in a vein deep inside the body. Veins in the thigh, foot, and calf create a natural pumping system that helps flow blood back to the heart. But when an individual is immobile, blood circulation is decreased, and the risk of developing a blood clot goes up. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad Helps control, stabilize and balance the foot. Heat moldable for a custom fit. SpenCore layer absorbs shock and reduces friction to improve overall foot comfort.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
Traction Machine The Traction Unit is the result of thousands of feedbacks from tens of thousands of physiotherapists over the past decade. Instead of a touch screen LCD panel and working through complicated windows, physiotherapists recommended the ease-to-adjust "HOLD" and "REST" knobs as they have been proven to be one of the fastest and effective ways of adjustments of traction force during treatment. The "HOLD" and "REST TIME" can be adjusted in real-time as well as the FORCE. Once set, press "START" and the new setting will take effect in the next coming cycle. The unit is equipped with a "Patient Switch" for full control of an Emergency Situation, all at the hands of a patient. Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
General Features
  • Perfected operating guidance through combination of 7" touchscreen and PHYSIOMED one-button operation
  • A comprehensive overview of the therapy parameters currently being used, including all therapy timers
  • Comprehensive list of indications with information on therapy, dosage suggestions, treatment images and intelligent filter functions by body region, desired therapy effect or alphabet for quick search of the desired treatment suggestion
  • Easy-to-use and extensive memory menu with treatment sequences and history function
  • Multifunctional intensity controller with intensity comfort swelling
  • Logical color coding of the stimulation current and vacuum application accessories for quick and safe assignment of the channels and the respective polarity
  • SD card slot for product updates
 
Features of electrical stimulation therapy
  • Two-channel electrotherapy with 21 current forms
  • Alternating and simultaneous stimulation
  • Spasticity treatment
  • Hand button as emergency stop switch or for intention exercises (optional)
  • Warnings when intensity is exceeded
  • Vacuum application with PHYSIOVAC-Expert (optional)
Medium frequency current forms:
  • IF (Classical Interference Current)
  • AMF (Amplitude Modulated Medium Frequency Current)
  • MT (Medium Frequency Muscle Stimulation)
  • KOTS (Russian Stimulation)
Low frequency current forms:
  • G (Galvanization)
  • GMC (Galvanization with Microcurrent)
  • DF (diadynamic current diphasé fixed)
  • MF (diadynamic current monophasé fixed)
  • CP (diadynamic current modulé en courtes périodes)
  • LP (Diadynamic current modulé en longues périodes)
  • UR (ultra-stimulation current according to Träbert)
  • HV (high voltage current)
  • TENS (Transcutaneous Electrical Nerve Stimulation)
  • MENS (Electrical Nerve Stimulation with Microcurrent)
  • IG 30 (impulse galvanization 30)
  • IG 50 (impulse galvanization 50)
  • FM (Frequency Modulated Current)
  • STOCH (Stochastic Current)
  • FaS (Faradic threshold current)
  • HVS (high voltage stimulation)
  • T/R (exponential current)
Diagnostics
  • Faradic excitability test
  • Medium frequency test according to Lange
  • Accommodation quotient
  • Rheobase/Chronaxis
  • I/T curve (with graphical representation of the curve)
  • I/T curve – quick test
Therapy information
Stimulation current therapy is an important component of electrotherapy. Stimulation currents are transmitted to the tissue to be treated via electrodes (plate electrodes, vacuum electrodes, adhesive electrodes). Depending on the type of current and the selection of parameters (i.e. pulse shape, pulse duration, pause time, frequency, intensity), stimulation currents can produce the following effects in the treatment area:
  • Musculoskeletal pain
  • Venous insufficiency/ulcers
  • Pressure ulcers
  • Strengthening the muscles
  • Iontophoresis
According to their origin and specific mode of action in the tissue, the following classification of the various stimulation currents can be made:
  • Medium frequency currents: these are alternating currents that are created by superimposing a base frequency (2-9.5 KHz) with a modulation frequency (0-250 Hz). With AMF current (amplitude-modulated medium frequency current) and medium frequency currents for muscle stimulation (MT and KOTS), this superimposition already takes place in the device. The pre-modulated current can therefore be delivered to the patient via just two electrodes. With classic interference current (IF), on the other hand, the two frequencies are only superimposed in the patient's tissue, which is why four electrodes are always required for treatment. The high therapeutic effectiveness of medium frequency currents is due to their minimal skin irritation and pronounced depth effect, which means they are well accepted by the patient.
  • Pulse currents with frequencies below 1000 Hz are considered low frequency. The various low frequency currents DF, MF, CP, LP (diadynamic currents), UR (ultra stimulation current), HV (high voltage current), FaS (faradic threshold current), TENS (mono- or bidirectional rectangular pulses) and T/R (exponential current) can cover the entire above-mentioned application area. In contrast to medium frequency currents, certain low frequency currents can also be used to increase muscle strength.
  • Galvanic current (G) is a direct current that flows through the tissue with constant energy. Galvanic current is mainly used to stimulate blood circulation and reduce pain, as well as for iontophoresis (introducing a preparation using current).
Selected use cases
Electrotherapy has an extremely wide range of applications. It is ideal for treating, among other things:
  • Osteoarthritis (knee joint)
  • CRPS Stage I and II
  • Epicondylitis
  • Radicular syndrome
  • Spasticity treatment according to Hufschmidt/Jantsch
  • Acceleration trauma
  • Chondropathia patellae
  • Joint effusion
  • Pain syndrome, postoperative
  • Ankylosing spondylitis
The Spenco Polysorb Walker Runner Insole offers contoured, flexible support to walkers, runners, and joggers looking for additional comfort and cushioning. It also provides targeted shock absorption for rear foot impact. Ideal for use in athletic, running, or walking shoes, the Polysorb Walker Runner Insole is made with Spencore material to absorb shock and impact for comfort and cushioning while the Spencore heel plug provides additional cushioning and shock absorption in the heel area. Lightweight Polysorb polyurethane foam provides heel cupping for a better fit and contoured arch support. To use the Spenco Polysorb Walker Runner Insole, simply remove the original insole from your shoe and use it as a guide to trace and trim the replacement insole before inserting it into your shoe. Hand wash in warm water and air dry as needed. The Spenco Polysorb Walker Runner Insole comes with a one-year unconditional guarantee.
  • 4-Way Stretch Fabric with Silpure Antimicrobial helps prevent blisters while controlling odor
  • SpenCore Material a 5 32inch layer of this material absorbs shock and impact to provide comfort and cushioning
  • Lightweight POLYSORB Polyurethane Foam provides heel cupping and contoured arch support
  • SpenCore Heel Plug provides extra cushioning and shock absorption in the heel
Weight 0.49
Body Part Arch, Plantar Fascia, Calf, Achilles, Shin, Back, Heel, Ball of Foot, Knee
Condition Plantar Fasciitis, Over Pronation, Flat Feet/Arch Support, Morton's Neuroma/Ball-of-Foot, Pain, Hammer Toe, Heel Spurs/Heel Pain
Activity Golf, Running, Hiking, Sports, Walking, Cross Training, Prolonged Standing
Insole Length Full
Shoe Type Run, Walk, Sport Specific, Work, Boots
Arch Type High
The Spenco RX Full Length Arch Cushions Insole provides heel-to-toe comfort. Recommended for people with general arch pain, this insole works well in dress, casual, and athletic shoes. Spencore material absorbs shock and impact for comfort with every step. A flexible arch cushion provides stability and support to help maintain proper position, which helps relieve and support tired feet. Silpure antimicrobial technology on the top cover prevents blisters and controls odor. The Spenco RX Arch Cushions insole is available in seven sizes for correct arch cushion placement to promote a better overall fit, comfort, and performance. May be hand washed in warm water and air dried as needed.
  • Full Length provides complete heel-to-toe comfort.
  • SpenCore Material Exclusive cushioning layer absorbs shock and impact to provide comfort.
  • Flexible Arch Cushion provides the additional stability and support necessary to help maintain proper foot position, while helping to relieve and support tired feet.
  • 7 Sizes for correct arch cushion placement for better overall fit, comfort and performance.
  • 4-way Stretch Fabric with Silpure Antimicrobial helps prevent blisters while controlling odor.
Specifications
Weight 0.27
Body Part Arch, Plantar Fascia, Calf, Achilles, Shin, Back, Heel, Ball of Foot, Knee
Condition Plantar Fasciitis, Over Pronation, Flat Feet/Arch Support, Morton's Neuroma/Ball-of-Foot, Pain, Hammer Toe, Heel Spurs/Heel Pain
Activity Golf, Running, Hiking, Sports, Office, Casual, Walking, Cross Training, Prolonged Standing
Insole Length Full
Shoe Type Run, Walk, Sport Specific, Work, Boots, Dress
Arch Type Medium
 
Deep vein thrombosis DVT-7700 MAIN is a DVT machine with HOSE and Accessories (Disposable sleeve thigh(M), Disposable sleeve calf(M), Disposable sleeve foot, and Tube (pair)) - Deep vein thrombosis (DVT) happens when a blood clot forms in a vein deep inside the body. Veins in the thigh, foot, and calf create a natural pumping system that helps flow blood back to the heart. But when an individual is immobile, blood circulation is decreased, and the risk of developing a blood clot goes up. DVT machine Specifications: Power requiremnet: 100V~240VAC, 50/60Hz Power Consumption: Maximum 18w Power Cord: Hospital Grade Plug (Detachable) Operation Mode: A1,A2,A3,B1,B2,B3,B4,C1,D1,D2 Adjustable Timer: 0-99 Hours Applied Pressure Leg sleeve: 30~60 mmHg (Caif, Thigh) Food Cuffs: 130mmHg Operation Mood: Continuous Compression Type: Leg sleeve: Gradient, Sequential Food Cuffs: Uniform Dimension: 200mm (L) * 190mm (W) * 260 mm (H) Weight: 2.3 kg (5.07 ib) Battery: Capacity 10.8 Vdc 4,400 mAh Lithiumion (optional) Run Time 6-8 Hours
Click Here To Download Catalogue
The Spenco RX Orthotic Arch Supports help control, stabilize, and balance the foot. The full length design provides heel to toe comfort. This insole provides firm arch support to reduce pronation and supination for improved stability. Ideal for use in casual and athletic shoes, including boots, the Spenco RX Orthotic Arch Supports come in a variety of sizes for correct arch placement to improve overall fit and comfort. Spencore material offers an cushioning layer that absorbs shock and impact while providing additional comfort. A 4-way stretch fabric with Silpure antimicrobial technology helps prevent blisters as it controls odor. Flexible plastic allows you to mold the insole to fit your foot for the perfect fit. Hand wash and air dry as needed.
  • Full Length provides complete heel-to-toe comfort.
  • SpenCore Material cushioning layer absorbs shock and impact to provide comfort.
  • Moldable Arch Insert The flexible plastic arch insert helps support and control the foot.
  • 7 Sizes for correct arch placement for better overall fit, comfort and performance.
  • 4-way Stretch Fabric with Silpure Antimicrobial helps prevent blisters while controlling odor.
Specifications
Weight 0.4
Body Part Arch, Plantar Fascia, Calf, Achilles, Shin, Back, Heel, Ball of Foot, Knee
Condition Plantar Fasciitis, Over Pronation, Flat Feet/Arch Support, Morton's Neuroma/Ball-of-Foot, Pain, Hammer Toe, Heel Spurs/Heel Pain
Activity Golf, Running, Hiking, Sports, Office, Casual, Walking, Cross Training, Prolonged Standing
Insole Length Full
Shoe Type Run, Walk, Sport Specific, Work, Boots, Dress
Arch Type Medium
Traction Machine
The Traction Unit is the result of thousands of feedbacks from tens of thousands of physiotherapists over the past decade. Instead of a touch screen LCD panel and working through complicated windows, physiotherapists recommended the ease-to-adjust "HOLD" and "REST" knobs as they have been proven to be one of the fastest and effective ways of adjustments of traction force during treatment. The "HOLD" and "REST TIME" can be adjusted in real-time as well as the FORCE. Once set, press "START" and the new setting will take effect in the next coming cycle. The unit is equipped with a "Patient Switch" for full control of an Emergency Situation, all at the hands of a patient.
Technical Specification:
  • Traction Force - The maximum force is 200 lb/91kg ± 4 lb/2kg
  • Traction Force Compensation - Computerized automatic compensation Actual force
  • Force Display - Actual force/ preset force - automatic switching display
  • Traction Speed - Stepless, continuous and adjustable
  • Therapy Mode - Intermittent/ Static/ Harmonic
  • Treatment Time - 1-99 minutes ± 2%
  • Safety System - Multiple protection alarms
  • Weight -1 lb (11.4 kg)
  • Dimension - 31(L) x28(W) x26(H) cm
Power Supply - 110-120 VAC (60Hz), 220-240 VAC (50Hz  
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information