Pilot-RO Water Purification System

$0.00

Shipped From Abroad

An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 – 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130126-2
Brands:: Hi-Tech

Description

An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 – 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments

Technical Parameters
Product Model Pilot-RO45 Pilot-RO63 Pilot-RO90 Pilot-RO120 Pilot-RO180
Pure water output* 45L/Hour 63L/Hour 90L/Hour 120L/Hour 180L/Hour
RO reverse osmosis water indicators
 Ion retention rate 98%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional 0.2μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.2μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Size and weight Length × width × height: 640 × 540 × 1110mm; Weight: about 70Kg
Electrical requirements 220V, 50/Hz
power 120W 120W 240W 240W 240W
System Configuration Main unit (including 1 set of purification column) + 2 built-in 15L pressure water buckets + TDS/conductivity test pen + accessory bag

Reviews

There are no reviews yet.

Be the first to review “Pilot-RO Water Purification System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPilot-RO Water Purification System removeSmart-RO Water Purification System removeOXYGEN & CARBON DIOXIDE MONITOR removeDISSUB ANALYSER removeFull Touch Screen Water Purification System removeCARBON MONOXIDE ATMOSPHERE MONITORING SYSTEM remove
NamePilot-RO Water Purification System removeSmart-RO Water Purification System removeOXYGEN & CARBON DIOXIDE MONITOR removeDISSUB ANALYSER removeFull Touch Screen Water Purification System removeCARBON MONOXIDE ATMOSPHERE MONITORING SYSTEM remove
Image
SKUSF1033560130126-2SF1033560130126-1SF1033560130141-12SF1033560130141-17SF1033560130126-4SF1033560130141-2
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad An economical choice of primary pure water for daily laboratory cleaning, with an hourly water output of 15-30 liters, ion retention rate >97%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the water requirements for routine laboratory ware cleaning and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Operating temperature 0 °C to 40 °C (32 °F to 104 °F)
  • Dual state-of-the-art oxygen and carbon dioxide sensors
  • Two analogue outputs, one for each gas detected
  • Maximum power consumption less than 5 watts
  • Designed to operate safely in a vacuum for four hours
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Proven hyperbaric sensing capability
  • You have the ability to change sensors and maintain the unit in the dockyard, reducing costs and downtime
  • Backlit display for low/no light situations
  • Portable and lightweight making it easy to use around the submarine
  • Externally accessible batteries making for more convenient and safer changing
  • MODBUS RTU over RS485 digital communications, allowing for easy incorporation into your existing platform management system, including JANUS enabled underwater communication networks
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The Center series uses city tap water as the water source, conveniently and quickly produces secondary RO reverse osmosis water, DI/EDI deionized water and UP ultrapure water. It adopts standard two-stage reverse osmosis system and EDI technology and modules*, and continuously produces Class II pure water with a TOC of more than 10MΩ.cm (25℃) and less than 30ppb*, and ultrapure water of 18.2MΩ.cm (25℃).There are currently four sub-product series of Center (Center-EDI) pure water and ultrapure water, and the system water output is: 45, 60, and 90 liters/hour.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad

The COSAMS unit was designed specifically for use on submarines, most directly those that operate on diesel engines. Built to exacting military standards for performance, reliability and endurance, the Analox COSAMS uses proprietary Gas Filter Correlation (GFC) technology to specifically analyze the unique properties of CO.

The COSAMS (Carbon Monoxide Submarine Atmosphere Monitoring System) has been designed for use on submerged submarines to support life, where crew can be living and working for up to 90 days. Carbon monoxide can be generated on a submarine in several ways, from cooking and fire, to the incomplete combustion of diesel fuel and chlorate candles.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentAn economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments
Technical Parameters
Product Model Pilot-RO45 Pilot-RO63 Pilot-RO90 Pilot-RO120 Pilot-RO180
Pure water output* 45L/Hour 63L/Hour 90L/Hour 120L/Hour 180L/Hour
RO reverse osmosis water indicators
 Ion retention rate 98%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional 0.2μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.2μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Size and weight Length × width × height: 640 × 540 × 1110mm; Weight: about 70Kg
Electrical requirements 220V, 50/Hz
power 120W 120W 240W 240W 240W
System Configuration Main unit (including 1 set of purification column) + 2 built-in 15L pressure water buckets + TDS/conductivity test pen + accessory bag
Technical Parameters
Product Model Smart-RO15 Smart-RO30
Pure water output* 15L/Hour 30L/Hour
Instantaneous water output** Up to 2.0L/Min (when there is water in the water tank)
RO reverse osmosis water indicators
 Ion retention rate 97%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional (0.45+0.1)μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.45+0.1)μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Instantaneous water output 2.0L/min (pressure water bucket required)
Water outlet 1: RO reverse osmosis water
Dimensions/weight Length × width × height: 41 × 22 × 42 cm / about 20 kg
Electrical requirements 100-240V, 50/60Hz
power 48W 72W
System Configuration Main unit (including 1 set of purification column) + 15L pressure water bucket + TDS/conductivity test pen + accessory bag
Consumables Information
Part Number/Model Product Name Service life/root (estimated)
PC-M-PP 5μmPP depth filter element About 2-6 months
PC-PP-ZK Zikang PP filter element About 2-6 months*
PC-AC-B-ZK Zikang activated carbon filter About 4-6 months*
PTC-AC-HZS1 Organic matter purification column About 6800 liters of pure water
RO-100GPD 100GPDRO membrane About 1-2 years
RO-200GPD 200GPDRO membrane About 1-2 years
PTC-MBR-K Deionization purification column (imported resin) About 1000 liters of pure water/column
PTC-UPPR-K Ultrapure water column (imported resin) About 1000 liters of pure water/column
TF-(0.45+0.1)μm-S (0.45+0.1)μm imported PES terminal filter -
UF-5000D MWCO5000DUF ultrafiltration component (original imported) -
UV-(185nm&254nm)-10W-K Dual wavelength (185nm & 254nm) UV lamp assembly (imported) -
LAMP-(185nm&254nm)-10W-K Dual wavelength (185 & 254nm) UV lamp (imported) About 9000 hours
UV-254-10W-K 254nmUV ultraviolet lamp assembly (imported lamp tube) -
LAMP-254-10W-K 254nm UV lamp (imported) About 9000 hours
Description
The SV-Multigas-2 is a dual oxygen (O2) and carbon dioxide (CO2) monitor designed for vehicles operating in the upper atmosphere. Housed in a robust, compact enclosure, the unit is ideal for use in airborne delivery systems, satellites and aircraft cabins. Since 2014 the SV-Multigas-2 has been successfully used in rockets travelling to outer space. Flexibility The SV-Multigas-2 incorporates user maintainable analogue sensors that provide a 1 to 5 V output. This modular approach to gas monitoring ensures that our customers have the flexibility to integrate the unit into their own system. It can be either installed directly in the gas path or used for general air monitoring.  
Technical Specification
SV-Multigas-2
Description

The Sub Mk3P Continuous Gas Monitor from Analox is designed specifically to monitor life support gasses aboard a submarine in the event of a distressed submarine (DISSUB) situation.

Portable and lightweight, the Sub Mk3P monitor provides crucial information to the senior survivor about the state of the atmosphere inside the submarine during a time of crisis. This information helps that officer make one of the most challenging decisions any submariner ever has to make – attempt to escape the submarine or wait for rescue teams.
Technical Specification

Temperature & Humidity Sensor

Main Unit
Battery power 4 x ‘D’ alkaline cells (Hyperbaric)
External power 24V dc (9-36V dc), <0.5A
Backup batteries 2 x LR43 alkaline manganese cells
Displays 6 x 4 character LCD, with symbols and LED backlights
Operating temperature -5 to 50°C
Storage temperature -5 to 50°C
Operating pressure 0.7 to 10barA
Operating humidity 0 to 100%RH (Non-condensing)
Standards/ compliance NATO STANAG 1476:2014 ANEP/MNEP 85 & 86 (2014) DEF STAN 59-411:2014 (EMC) IACs E10:2014 (MarED) type tested IP65 CE marked (RoHS)"
Dimensions (W, H, D) 240mm x 198mm x 127mm
Weight 2kg with batteries installed
O2 Sensor
Range 0 to 2000mbar pO2
Accuracy ±10mbar (0 to 300mbar pO2) ±50mbar (300 to 2000mbar pO2)
Response time (t90) 20s
Detection mode Electro-chemical
Shelf life (in sealed packaging) 6 months
Expected life (in air) 12 months
CO2 Sensor
Range 0 to 100mbar pCO2
Accuracy ±10mbar
Response time (t90) 60s
Detection mode Infrared
Expected life (in air) 5 years
Pressure Sensor
Range 0.7 to 10barA (-3 to 90MSW or -10 to 300FSW)
Accuracy (including annual drift) -0.07bar +0.04bar
Response time (t90) <1s
Detection mode Piezoresistive
Expected life (in air) >12 months (Replaced as a part of the O2sensor)
Click here to download Data Sheet
Click here to download Technical Manual
Performance characteristics
  • New 7.0-inch color touch screen

Animated menu, system information at a glance, and a new fingertip touch operation experience.

  • The lab optimized standard two-stage reverse osmosis system

The use of dual pumps, dual membranes and transition water tanks reduces system energy consumption, reduces wastewater and produces more stable water quality.

  • Advanced EDI technology and modules

Providing you with consistent 10MΩ.cm grade high purity water at an optimized operating cost.

  • Removable water tray

Prevent water droplets from splashing, store water in time, facilitate cleaning, and keep the system clean.

  • Built-in double water tank
Built-in 20L PE water tank and 1 20L pressure water bucket, saving more experimental space and eliminating the inconvenience of external water bucket.
Features and Advantages
  • The ultrapure water circulation system can be started and shut down freely to maintain the low bacterial contamination level of the system
  • Ultrapure water full pipeline disinfection program, can manually execute "circulation disinfection", "water inlet disinfection", "water tank filling", "manual sewage discharge", "stop disinfection"
  • Fully automatic RO membrane anti-scaling flushing (flushing interval and duration can be set) and manual forced flushing program to extend the service life of the RO membrane
  • The life of PP, KDF, AC, RO, UP, UF, TF, and UV consumables can be set, and the used time can be displayed, and automatic replacement reminders will be given when the time expires.
  • Water shortage and water full alarm, source water, RO reverse osmosis water, DI deionized water/UP ultrapure water exceeding the standard alarm
  • Compatible with two pure water storage methods: pressure water bucket and liquid level water tank, which can directly display the water storage capacity of the water tank to meet different application needs
  • System time setting (year/month/day/hour/minute), timed standby (0~60min), timed shutdown (0~24hour) functions
  • Record and check the replacement time of consumables at any time to fully grasp the equipment maintenance information
  • Complete information query and data management functions, fully control system operation status, water quality, consumables usage, timely alarm, historical alarm and other information
  • The entire pipeline adopts quick plug-in interface, and all pipes and joints are NSF certified
  • DOW RO reverse osmosis membrane ensures stable operation and high desalination rate
  • DOW's high-purity nuclear-grade resin ensures that the water produced reaches 18.2MΩ.cm and reduces TOC precipitation
  • Ultra-long life 254 & 185nm dual wavelength UV lamp, effective sterilization, reducing TOC
  • MWCO 5000D UF ultrafiltration module, effectively removes endotoxins/pyrogens
  • 0.2μm PES polyethersulfone composite membrane terminal filter to ensure pure water quality
Key Features
  • Uses a GFC infra-red sensing technique ensuring the system is not sensitive to hydrogen or water vapor
  • Built-in auto-zero function ensures sensor stability
  • Real-time monitoring ensures rapid response to carbon monoxide (CO) issues as they occur
  • 90 days data-logging allows records to be stored and used should they ever be needed
  • Easy to maintain allowing you to be more self-sufficient whilst minimizing downtime
  • Designed specifically for the submarine environment so it is able to cope with the demands of the environment in terms of EMC, shock and temperature
 
Technical Specifications

Click here to download Data Sheet
Click here to download Manual
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare