/

Pilot-RO Water Purification System

$0.00

Shipped From Abroad

An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 – 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130126-2
Brands:: Hi-Tech

Description

An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 – 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments

Technical Parameters
Product Model Pilot-RO45 Pilot-RO63 Pilot-RO90 Pilot-RO120 Pilot-RO180
Pure water output* 45L/Hour 63L/Hour 90L/Hour 120L/Hour 180L/Hour
RO reverse osmosis water indicators
 Ion retention rate 98%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional 0.2μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.2μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Size and weight Length × width × height: 640 × 540 × 1110mm; Weight: about 70Kg
Electrical requirements 220V, 50/Hz
power 120W 120W 240W 240W 240W
System Configuration Main unit (including 1 set of purification column) + 2 built-in 15L pressure water buckets + TDS/conductivity test pen + accessory bag

Reviews

There are no reviews yet.

Be the first to review “Pilot-RO Water Purification System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPilot-RO Water Purification System removeDISTRIBUTED ATMOSPHERE MONITORING SYSTEM removeTimesco Jumper Fingertip Pulse Oximeter removeSmart-RO Water Purification System removeLOW LEVEL CARBON MONOXIDE MONITOR removeFlowMir Disposable Turbine with Cardboard Mouthpiece remove
NamePilot-RO Water Purification System removeDISTRIBUTED ATMOSPHERE MONITORING SYSTEM removeTimesco Jumper Fingertip Pulse Oximeter removeSmart-RO Water Purification System removeLOW LEVEL CARBON MONOXIDE MONITOR removeFlowMir Disposable Turbine with Cardboard Mouthpiece remove
ImageFingertip Pulse OximeterFlowMir Disposable Turbine with Cardboard Mouthpiece
SKUSF1033560130126-2SF1033560130141-14SF1033560084-2SF1033560130126-1SF1033560130141-4SF1033560084-22
Rating
Price

$0.00

$0.00

$17.00

$0.00

$0.00

$145.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad An economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Optional Submarine PMS (Platform Management System) integration
  • Customized user interface/HMI
  • Datalogging
  • Download port
  • Visual alarms with alarm location
  • Password protection
  • Choice of gas sensing modules: oxygen (O2), carbon dioxide (CO2), carbon monoxide (CO), hydrogen (H2) and refrigerants
  • Local visual alarms
  • Optional relays
  • Temperature compensated
  • User maintainable
  • Partial pressure sensing
  • MIL-STD-461F compliant
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad An economical choice of primary pure water for daily laboratory cleaning, with an hourly water output of 15-30 liters, ion retention rate >97%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the water requirements for routine laboratory ware cleaning and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Key Features
  • Highly accurate 4-pin sensor
  • >3-year expected cell life
  • Temperature compensation Sub-ppm gas measurement
  • RS485 digital output
  • Optional pressure sensor
  • Easy cell replacement
  • High stability, low drift
  • Easy cell replacement
  • High stability, low drift
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Spirometry testing requires maximum accuracy and hygiene. Each Flowmir disposable turbine, which includes a cardboard mouthpiece, has been individually factory calibrated with a computerized system and it is packaged individually. FlowMIR® is an inexpensive alternative to a costly reusable flowmeter and replaces the need for an antibacterial filter Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentAn economical choice of primary pure water for daily laboratory cleaning , with a water output of 45 - 180 liters per hour, ion retention rate >98%, organic matter retention rate >99% (when MW >200 Daltons), particle and bacteria retention rate >99%, which can meet the requirements of conventional production process water and laboratory utensil cleaning water, and can be used as the inlet water for ultrapure water systems, high-pressure steam sterilizers, environmental test chambers and other instruments
Technical Parameters
Product Model Pilot-RO45 Pilot-RO63 Pilot-RO90 Pilot-RO120 Pilot-RO180
Pure water output* 45L/Hour 63L/Hour 90L/Hour 120L/Hour 180L/Hour
RO reverse osmosis water indicators
 Ion retention rate 98%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional 0.2μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.2μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Size and weight Length × width × height: 640 × 540 × 1110mm; Weight: about 70Kg
Electrical requirements 220V, 50/Hz
power 120W 120W 240W 240W 240W
System Configuration Main unit (including 1 set of purification column) + 2 built-in 15L pressure water buckets + TDS/conductivity test pen + accessory bag
Description
The DAMS (Distributed Atmosphere Monitoring System) is a flexible, robust and fully configurable, submarine atmosphere monitoring system. Designed with you in mind, this life-saving, mission critical equipment offers multi-point sensing for AIP or Diesel Electric subs and is suitable for new submarine designs or mid-life upgrades.

Gas sensors are monitored centrally via the PLC and offer local sensing and alerts for the crew in the aft, middle and fore of your boat, giving you true peace of mind throughout the duration of your patrol.

 
Technical Specification
DAMS SPECIFICATION  
Characteristics

Flexibility

No matter a submarine’s size or what country’s flag it flies, it is a fact that no two submarines are the same. Every vessel has unique gas monitoring needs and requires an analytical tool with the versatility to be configured to each vessel’s individual requirements. Each state-of-art DAMS unit is flexible, robust and fully configurable and can monitor up to six different gasses simultaneously from one centralized PLC (programmable logic controller) panel.  

Communication

Easily the most versatile and customizable product in the entire Analox line, DAMS quite simply is a centralized hub that allows multiple analyzers and monitors located in multiple locations throughout a submarine to communicate with each other. With the integral communication to the ships platform management systems, should an alarm be triggered, the duty officer is ideally positioned and instantly informed to take appropriate corrective action without having to leave the Con, or central control room.

 

Testing

The modular design of the DAMS incorporates multiple testing technologies including GFC to monitor carbon monoxide (CO), electrochemical for depleted or enriched oxygen (O2), NDIR for carbon dioxide (CO2) and refrigerants (R134a) and Catalytic Bead technology to test for hydrogen (H2). Each DAMS monitor is ideally suited for conventionally powered diesel/electric powered submarines or air-independent propulsion (AIP) designs.

Each DAMS unit is shock, pressure and temperature compensated and tested to withstand the demanding submarine environment. This highly versatile tool can be tailored to customer-specific requirements for EMC (electro-magnetic capability), durability, vibration and noise interference. Having successfully passed rigorous sea trials and laboratory testing, DAMS units are currently deployed with multiple naval groups throughout the world. In response to highly precise military standards and requirements, DAMS is simple to customize and install. Each unit is user maintainable, and has delivered the proven accuracy and reliability demanded by the submarine community. The modular design of DAMS allows for upgrades and changes to the system as the vessel’s operational requirements change throughout the product’s operational life.

Easy Calibration

Each DAMS system can be calibrated by just one person and is extremely easy to maintain, reducing and often eliminating disruptions to normal operations. Analox also offers multi-gas sensors that can be calibrated simultaneously.
Click here to download Data Sheet
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User Manual
Technical Parameters
Product Model Smart-RO15 Smart-RO30
Pure water output* 15L/Hour 30L/Hour
Instantaneous water output** Up to 2.0L/Min (when there is water in the water tank)
RO reverse osmosis water indicators
 Ion retention rate 97%-99% (when using new RO membrane)
 Organic matter retention rate >99%, when MW>200 Daltons
 Particle and bacteria retention >99%
 bacteria <0.01 cfu/ml (optional (0.45+0.1)μm imported PES terminal filter)
 Particles (>0.2μm) <1/ml (optional (0.45+0.1)μm imported PES terminal filter)
Raw water requirements Urban drinking tap water, water temperature 5-45℃, water pressure 1.0-4.0Kgf/ cm2
Instantaneous water output 2.0L/min (pressure water bucket required)
Water outlet 1: RO reverse osmosis water
Dimensions/weight Length × width × height: 41 × 22 × 42 cm / about 20 kg
Electrical requirements 100-240V, 50/60Hz
power 48W 72W
System Configuration Main unit (including 1 set of purification column) + 15L pressure water bucket + TDS/conductivity test pen + accessory bag
Consumables Information
Part Number/Model Product Name Service life/root (estimated)
PC-M-PP 5μmPP depth filter element About 2-6 months
PC-PP-ZK Zikang PP filter element About 2-6 months*
PC-AC-B-ZK Zikang activated carbon filter About 4-6 months*
PTC-AC-HZS1 Organic matter purification column About 6800 liters of pure water
RO-100GPD 100GPDRO membrane About 1-2 years
RO-200GPD 200GPDRO membrane About 1-2 years
PTC-MBR-K Deionization purification column (imported resin) About 1000 liters of pure water/column
PTC-UPPR-K Ultrapure water column (imported resin) About 1000 liters of pure water/column
TF-(0.45+0.1)μm-S (0.45+0.1)μm imported PES terminal filter -
UF-5000D MWCO5000DUF ultrafiltration component (original imported) -
UV-(185nm&254nm)-10W-K Dual wavelength (185nm & 254nm) UV lamp assembly (imported) -
LAMP-(185nm&254nm)-10W-K Dual wavelength (185 & 254nm) UV lamp (imported) About 9000 hours
UV-254-10W-K 254nmUV ultraviolet lamp assembly (imported lamp tube) -
LAMP-254-10W-K 254nm UV lamp (imported) About 9000 hours
Description
The TEC CO is a device for monitoring very low levels of carbon monoxide (CO). This is housed in a robust miniature enclosure rated for IP55 ingress protection, with built-in temperature compensation and an RS485 digital output via Analox communications protocol. The sensors are backwards-compatible with the existing MEC (mini electrochemical) range and offer the same modular approach to gas monitoring.  
Technical Specifications
TEC CO
    • Comfortable Packaging
    • Singularly Tested and Packed
    • Always 100% accurate and hygienic
    • No Calibration required
    • No Sterilization required
    • No Antibacterial Filter required
    • No Cross Contamination
    • Not affected by Vapour Condensation
    • Not affected by Ambient conditions
    •  A full Spirometry session can be performed, including a Bronchial Challenge and POST Bronchodilator test. For each patient after the Spirometry test, both turbine and spirometer mouthpiece are thrown away
    • .
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare