Pocket pH Meter 3 Points

$0.00

Shipped From Abroad

Model : PH-30SP; PH-30FP; PH-30LP

The pocket pH tester’s 3 points calibration ensures measurement accuracy for a variety of applications including agriculture, aquaculture, hydroponics and more! Now the best pocket pH tester for sale at cost price.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-89
Brands:: Scitek

Description

Pocket pH Tester Features:

The measurement material is the main difference between the three pocket pH tester types.

Differences:

  1. PH-30SP: Round glass bulb pH electrode for measuring the pH of regular water samples.
  2. PH-30FP: Flat surface pH electrode for measuring semi-solid and gel samples.
  3. PH-30LP: Cone-shaped pH-sensitive membrane for piercing and measuring semi-solid samples such as soil, cheese, etc.

 

Pocket pH Tester Specifications:
Model PH-30SP PH-30FP PH-30LP
pH
Range -1.00 to 15.00pH -1.00 to 15.00pH -1.00 to 15.00pH
Resolution 0.01pH 0.01pH 0.01pH
Accuracy ±0.01pH ±0.01pH ±0.01pH
Calibration Points 1 to 3 points 1 to 3 points 1 to 3 points
pH Buffer Options USA(pH4.01/7.00/10.01) NIST(pH4.01/6.86/9.18) USA(pH4.01/7.00/10.01) NIST(pH4.01/6.86/9.18) USA(pH4.01/7.00/10.01) NIST(pH4.01/6.86/9.18)
Temperature
Range 0 to 60°C/32 to 140°F 0 to 60°C/32 to 140°F 0 to 60°C/32 to 140°F
Resolution 0.1°C/0.1°F 0.1°C/0.1°F 0.1°C/0.1°F
Accuracy ±1°C/±1.8°F ±1°C/±1.8°F ±1°C/±1.8°F
Offset Calibration 1 point 1 point 1 point
Calibration Range Reading ±10°C Reading ±10°C Reading ±10°C
General Specifications
Temperature Compensation 0 to 60°C/32 to 140°F, automatic 0 to 60°C/32 to 140°F, automatic 0 to 60°C/32 to 140°F, automatic
Hold Function Manual or auto-endpoint Manual or auto-endpoint Manual or auto-endpoint
Auto-Power Off 8 minutes after the last key is pressed 8 minutes after the last key is pressed 8 minutes after the last key is pressed
Display Dual-line LCD (21×21mm) Dual-line LCD (21×21mm) Dual-line LCD (21×21mm)
Power 2×1.5V AAA batteries 2×1.5V AAA batteries 2×1.5V AAA batteries
Battery Life Approximately 200 hours of continuous use Approximately 200 hours of continuous use Approximately 200 hours of continuous use
Sizes(W×D×H)(mm) 185(L)×40(Dia.) 185(L)×40(Dia.) 240(L)×40(Dia.)
Shipping Size (W×D×H)(mm) 330x150x280
N.W./G.W. (kg) 0.1/1.5

Reviews

There are no reviews yet.

Be the first to review “Pocket pH Meter 3 Points”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPocket pH Meter 3 Points removeSkyla Hi POC Clinical Chemistry Analyzer removeAvalun 48 INR Microcuvette removeIISM VPism-C (Compact Type) Vein Probe removeErma B-111 Bilirubin Meter removeAlcohol Pad Per Pack remove
NamePocket pH Meter 3 Points removeSkyla Hi POC Clinical Chemistry Analyzer removeAvalun 48 INR Microcuvette removeIISM VPism-C (Compact Type) Vein Probe removeErma B-111 Bilirubin Meter removeAlcohol Pad Per Pack remove
ImageAvalun 48 INR MicrocuvetteIISM VPism-C (Compact Type) Vein Probe
SKUSF1033560130127-89SF1033560060-2SF1033560084-74SF1033560090-1SF1033560084-6SF1033560084-64
Rating
Price

$0.00

$0.00

$0.00

$0.00

$715.00

$4.25

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From Abroad Model : PH-30SP; PH-30FP; PH-30LP The pocket pH tester's 3 points calibration ensures measurement accuracy for a variety of applications including agriculture, aquaculture, hydroponics and more! Now the best pocket pH tester for sale at cost price.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Pocket pH Tester Features:
The measurement material is the main difference between the three pocket pH tester types. Differences:
  1. PH-30SP: Round glass bulb pH electrode for measuring the pH of regular water samples.
  2. PH-30FP: Flat surface pH electrode for measuring semi-solid and gel samples.
  3. PH-30LP: Cone-shaped pH-sensitive membrane for piercing and measuring semi-solid samples such as soil, cheese, etc.
 
Pocket pH Tester Specifications:
Model PH-30SP PH-30FP PH-30LP
pH
Range -1.00 to 15.00pH -1.00 to 15.00pH -1.00 to 15.00pH
Resolution 0.01pH 0.01pH 0.01pH
Accuracy ±0.01pH ±0.01pH ±0.01pH
Calibration Points 1 to 3 points 1 to 3 points 1 to 3 points
pH Buffer Options USA(pH4.01/7.00/10.01) NIST(pH4.01/6.86/9.18) USA(pH4.01/7.00/10.01) NIST(pH4.01/6.86/9.18) USA(pH4.01/7.00/10.01) NIST(pH4.01/6.86/9.18)
Temperature
Range 0 to 60°C/32 to 140°F 0 to 60°C/32 to 140°F 0 to 60°C/32 to 140°F
Resolution 0.1°C/0.1°F 0.1°C/0.1°F 0.1°C/0.1°F
Accuracy ±1°C/±1.8°F ±1°C/±1.8°F ±1°C/±1.8°F
Offset Calibration 1 point 1 point 1 point
Calibration Range Reading ±10°C Reading ±10°C Reading ±10°C
General Specifications
Temperature Compensation 0 to 60°C/32 to 140°F, automatic 0 to 60°C/32 to 140°F, automatic 0 to 60°C/32 to 140°F, automatic
Hold Function Manual or auto-endpoint Manual or auto-endpoint Manual or auto-endpoint
Auto-Power Off 8 minutes after the last key is pressed 8 minutes after the last key is pressed 8 minutes after the last key is pressed
Display Dual-line LCD (21×21mm) Dual-line LCD (21×21mm) Dual-line LCD (21×21mm)
Power 2×1.5V AAA batteries 2×1.5V AAA batteries 2×1.5V AAA batteries
Battery Life Approximately 200 hours of continuous use Approximately 200 hours of continuous use Approximately 200 hours of continuous use
Sizes(W×D×H)(mm) 185(L)×40(Dia.) 185(L)×40(Dia.) 240(L)×40(Dia.)
Shipping Size (W×D×H)(mm) 330x150x280
N.W./G.W. (kg) 0.1/1.5
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. This handheld, portable device is lightweight and includes the touchscreen and camera with attached clip. The camera can be removed and handled by hand, or can clip to the touchscreen unit for a hands-free experience. The back of the device also has a kickstand, so that physicians can stand the device on its own. The VPism-C can also be mounted to an armrest, if a patient needs to be stationary, or attached to a SLism-F Specialized Light Source for patients with deeper vessels. This device can be a vital tool in providing accurate placement of injections or other vascular treatments, such as for varicose veins. The infrared video shows the location of the veins and capillaries in real time, as well as save images for further discussion or diagnosis. For patients who have difficult-to-find veins, this device will save them from incorrect or painful injection sites. Features: Probe Target: Subcutaneous blood vessels of various patients (including capillaries) Probe Method: Non-invasive infrared technology Probe Depth: Within 10 mm under the skin Magnification Function: Up to 1X, 2X and 4X Automatic Adjustment Function: Adjusts the brightness automatically based on the targeted vein Specialized Light Function: Shows the veins more clearly by using the specialized light source Operation Method: Easy to operate with touchscreen Internal Battery Support: Continuous running time: 1.5 hours Warranty: 1 year
Click Here To Download Catalogue
 
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Model

Advanced, Advanced Plus, Basic, Smart

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare