Portable Multiparameter Water Quality Meter

$0.00

Shipped From Abroad

These multi-parameter water quality meters contain a varying number of measurement functions. You can choose the measurement functions according to your needs. A water quality meter can measure pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity, and DO. Designed for water quality professionals, the multiparameter water quality meter is an advanced laboratory meter that takes the guesswork out of measurement.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-46
Brands:: Scitek

Description

Multiparameter Water Quality Meter Features:

 

  1. The probes are made of high-quality titanium alloy for accurate measurement, which is more sensitive and lasts longer.
  2. 1 to 5-point calibration, automatic recognition of USA, NIST, DIN standard buffers.
  3. Reliable Automatic Temperature Compensation (ATC) ensures accurate measurements in water sources of all temperatures.
  4. The water quality meter turns off automatically after a few minutes of inactivity to save batteries.
  5. Automatically saves the measurement results after completion, making it easy to view the data later.
  6. Ideal for aquariums, hydroponics, marine, aquaculture and any water source.
  7. Concentration units (ppm, mg/L, mol/L, mmol/L) and ionic media are selectable
  8. Salinity and atmospheric pressure compensation eliminates measurement errors.
  9. USB interface for easy data transfer
  10. Can save 500 sets of measurement data for easy comparison

 

Multiparameter Water Quality Meter Specifications:
Model MWQ-P900 MWQ-P901 MWQ-P902 MWQ-P903 MWQ-P904
pH Range -2.000-20.000pH –
Resolution 0001,0.01,0.1pH, selectable –
Accuracy 0.002pH –
Calibration Points 1 to 5 points –
pH Buffer Options USA, NIST, DIN, 2 custom buffers –
ORP Range ±1999.9mV –
Resolution 0.1, 1mV, selectable –
Accuracy ±0.2mV –
Calibration Points 1 point –
Ion Range 0.001~19999 (depending on the range of ISE) – – – –
Resolution 0.001, 0.01, 0.1, 1 – – – –
Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent) – – – –
Measurement Units ppm, mg/L, mol/L, mmol/L – – – –
Calibration Paints 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) – – – –
Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm – 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0001,0.01,0.1,1 – 0001,0.01,0.1,1
Accuracy ±0.5% F.S. – ±0.5% F.S.
Calibration Paints 1 to 5 points – 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm – 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Coefficient Linear(0.0-10.0%/°C ).pure water – Linear(0.0-10.0%/°C ).pure water
Reference Temperature 20/25°C – 20/25°C
Cell Constant K=0.1, 1, 10 or custom – K=0.1, 1, 10 or custom
TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt – 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution 001,0.1,1 – 001,0.1,1
Accuracy ±1% F.S. – ±1% F.S.
TDS Factor 0.1~1.0 (default 0.5) – 0.1~1.0 (default 0.5)
Salinity Range 0.00~42.00psu, 0.00~80.00ppt – 0.00~42.00 psu, 0.00~80.00 ppt – 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01 – 0.01 – 0.01
Accuracy ±1% F.S. – ±1% F.S. – ±1% F.S.
Resistivity Range 0.00~20.00MΩ – 0.00~20.00 MΩ – 0.00~20.00MΩ
Resolution 0.01 – 0.01 – 0.01
Accuracy ±1% F.S. – ±1% F.S. ±1% F.S. ±1% F.S.
DO Range 0.00~20.00mg/L, 0.0~200.0% saturation – – 0.00~20.00 mg/L 0.00~20.00mg/L, 0.0~200.0% saturation
0.0~200.0% saturation
Resolution 001mg/L,0.1% – – 001mg/L, 0.1% 001mg/L,0.1%
Accuracy ±0.2mg/L, ±2.0% – – ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0%
Calibration Points 1 or 2 points – – 1 or 2 points 1 or 2 points
Barometric Pressure Correction 60.0~112.5kPa/ 450~850mmHg, manual – – 60.0~112.5 kPa/ 450~850 mmHg, manual 60.0~112.5 kPa/ 450~850 mmHg, manual
Salinity Correction 0.0~50.0g/L, manual – – 0.0~50.0g/L, manual 0.0~50.0g/L, manual
General Spec. Temperature Compensation 0~100°C/32~212°F, manual or automatic
Memory 500 data sets, USB communication interface
Power Requirements 3× 1.5V AA batteries or DC5V power adapter
Sizes(W×D×H)(mm) 170× 85×30
Shipping Size (W×D×H)(mm) 450x320x100
N.W./G.W. (kg) 0.3/2

Reviews

There are no reviews yet.

Be the first to review “Portable Multiparameter Water Quality Meter”

Your email address will not be published. Required fields are marked *

Quick Comparison

Portable Multiparameter Water Quality Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeAvalun LabPad Device removeDiscover 5 Panel Cup with Adulterants Per Pack removeIISM VPism-C (Compact Type) Vein Probe removeErma B-111 Bilirubin Meter remove
NamePortable Multiparameter Water Quality Meter removeSkyla Hi POC Clinical Chemistry Analyzer removeAvalun LabPad Device removeDiscover 5 Panel Cup with Adulterants Per Pack removeIISM VPism-C (Compact Type) Vein Probe removeErma B-111 Bilirubin Meter remove
ImageAvalun Labpad machineDrug Test CupIISM VPism-C (Compact Type) Vein Probe
SKUSF1033560130127-46SF1033560060-2SF1033560084-65SF1033560084-23SF1033560090-1SF1033560084-6
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$715.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad These multi-parameter water quality meters contain a varying number of measurement functions. You can choose the measurement functions according to your needs. A water quality meter can measure pH, ORP, Ion, Conductivity, TDS, Salinity, Resistivity, and DO. Designed for water quality professionals, the multiparameter water quality meter is an advanced laboratory meter that takes the guesswork out of measurement.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
The Discover Cup is an all-in-one drug of abuse test cup. The strips are self-contained and the entire cup is tamper resistant. Delivery & Availability:
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Multiparameter Water Quality Meter Features:
 
  1. The probes are made of high-quality titanium alloy for accurate measurement, which is more sensitive and lasts longer.
  2. 1 to 5-point calibration, automatic recognition of USA, NIST, DIN standard buffers.
  3. Reliable Automatic Temperature Compensation (ATC) ensures accurate measurements in water sources of all temperatures.
  4. The water quality meter turns off automatically after a few minutes of inactivity to save batteries.
  5. Automatically saves the measurement results after completion, making it easy to view the data later.
  6. Ideal for aquariums, hydroponics, marine, aquaculture and any water source.
  7. Concentration units (ppm, mg/L, mol/L, mmol/L) and ionic media are selectable
  8. Salinity and atmospheric pressure compensation eliminates measurement errors.
  9. USB interface for easy data transfer
  10. Can save 500 sets of measurement data for easy comparison
 
Multiparameter Water Quality Meter Specifications:
Model MWQ-P900 MWQ-P901 MWQ-P902 MWQ-P903 MWQ-P904
pH Range -2.000-20.000pH –
Resolution 0001,0.01,0.1pH, selectable –
Accuracy 0.002pH –
Calibration Points 1 to 5 points –
pH Buffer Options USA, NIST, DIN, 2 custom buffers –
ORP Range ±1999.9mV –
Resolution 0.1, 1mV, selectable –
Accuracy ±0.2mV –
Calibration Points 1 point –
Ion Range 0.001~19999 (depending on the range of ISE) – – – –
Resolution 0.001, 0.01, 0.1, 1 – – – –
Accuracy ±0.5% F.S. (monovalent), ±1% F.S. (divalent) – – – –
Measurement Units ppm, mg/L, mol/L, mmol/L – – – –
Calibration Paints 2 to 5 points (0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000) – – – –
Conductivity Range 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm – 0.01~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Resolution 0001,0.01,0.1,1 – 0001,0.01,0.1,1
Accuracy ±0.5% F.S. – ±0.5% F.S.
Calibration Paints 1 to 5 points – 1 to 5 points
Calibration Solutions 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm – 10µS/cm, 84µS/cm, 1413µS/cm, 12.88mS/cm, 111.8mS/cm
Temperature Coefficient Linear(0.0-10.0%/°C ).pure water – Linear(0.0-10.0%/°C ).pure water
Reference Temperature 20/25°C – 20/25°C
Cell Constant K=0.1, 1, 10 or custom – K=0.1, 1, 10 or custom
TDS Range 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt – 0~10.00, 100.0, 1000ppm, 10.00, 200.0ppt
Resolution 001,0.1,1 – 001,0.1,1
Accuracy ±1% F.S. – ±1% F.S.
TDS Factor 0.1~1.0 (default 0.5) – 0.1~1.0 (default 0.5)
Salinity Range 0.00~42.00psu, 0.00~80.00ppt – 0.00~42.00 psu, 0.00~80.00 ppt – 0.00~42.00psu, 0.00~80.00ppt
Resolution 0.01 – 0.01 – 0.01
Accuracy ±1% F.S. – ±1% F.S. – ±1% F.S.
Resistivity Range 0.00~20.00MΩ – 0.00~20.00 MΩ – 0.00~20.00MΩ
Resolution 0.01 – 0.01 – 0.01
Accuracy ±1% F.S. – ±1% F.S. ±1% F.S. ±1% F.S.
DO Range 0.00~20.00mg/L, 0.0~200.0% saturation – – 0.00~20.00 mg/L 0.00~20.00mg/L, 0.0~200.0% saturation
0.0~200.0% saturation
Resolution 001mg/L,0.1% – – 001mg/L, 0.1% 001mg/L,0.1%
Accuracy ±0.2mg/L, ±2.0% – – ±0.2mg/L, ±2.0% ±0.2mg/L, ±2.0%
Calibration Points 1 or 2 points – – 1 or 2 points 1 or 2 points
Barometric Pressure Correction 60.0~112.5kPa/ 450~850mmHg, manual – – 60.0~112.5 kPa/ 450~850 mmHg, manual 60.0~112.5 kPa/ 450~850 mmHg, manual
Salinity Correction 0.0~50.0g/L, manual – – 0.0~50.0g/L, manual 0.0~50.0g/L, manual
General Spec. Temperature Compensation 0~100°C/32~212°F, manual or automatic
Memory 500 data sets, USB communication interface
Power Requirements 3× 1.5V AA batteries or DC5V power adapter
Sizes(W×D×H)(mm) 170× 85×30
Shipping Size (W×D×H)(mm) 450x320x100
N.W./G.W. (kg) 0.3/2
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8ËšC
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ËšC
Click Here To Download Catalogue
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
All-in-One Design
FDA 510K & CLIA Waived 99% Accurate Results in as little as 1 minute 24 Month Shelf Life from Date of Manufacture Secure, seal and send to lab for confirmation Built in temperature strip Available to test up to 14 substances Adulterants available
 
 
The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. This handheld, portable device is lightweight and includes the touchscreen and camera with attached clip. The camera can be removed and handled by hand, or can clip to the touchscreen unit for a hands-free experience. The back of the device also has a kickstand, so that physicians can stand the device on its own. The VPism-C can also be mounted to an armrest, if a patient needs to be stationary, or attached to a SLism-F Specialized Light Source for patients with deeper vessels. This device can be a vital tool in providing accurate placement of injections or other vascular treatments, such as for varicose veins. The infrared video shows the location of the veins and capillaries in real time, as well as save images for further discussion or diagnosis. For patients who have difficult-to-find veins, this device will save them from incorrect or painful injection sites. Features: Probe Target: Subcutaneous blood vessels of various patients (including capillaries) Probe Method: Non-invasive infrared technology Probe Depth: Within 10 mm under the skin Magnification Function: Up to 1X, 2X and 4X Automatic Adjustment Function: Adjusts the brightness automatically based on the targeted vein Specialized Light Function: Shows the veins more clearly by using the specialized light source Operation Method: Easy to operate with touchscreen Internal Battery Support: Continuous running time: 1.5 hours Warranty: 1 year
Click Here To Download Catalogue
 
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Model

Advanced, Advanced Plus, Basic, Smart

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar