Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- DSP digital control technology enables UPS more stable performance-+
- Environment friendly eco-designed
- Active input power factor correction
- Wide range of input voltage and frequency
- Zero power switch delay
- Adaptive Load Management.
- Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
- Support the generator
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- 60KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- 50KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | Features:
- Capacity: 1200W 1008Wh /315000mAh
- Input AC Output Power:Rated Power 1200W Peak Power 2400W
- Input AC Charging:AC100~125V/AC184~264V Bidirectional Inverter 700W Max
- Input Car Charging:DC12V~24V/10A 240W Max
- Input Solar Charging:DC12V~60V/10A 400W Max
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*5V2.4A +2*QC18W+2*PD60W Max
- DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support(≤10mS)
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
| Features:
- DSP digital control technology enables UPS more stable performance-+
- Environment friendly eco-designed
- Active input power factor correction
- Wide range of input voltage and frequency
- Zero power switch delay
- Adaptive Load Management.
- Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
- Support the generator
Specifications:
Model |
33VT 10K |
33VT 10KL |
33VT 20K |
33VT 20KL |
33VT 30KL |
33VT 40KL |
Capacity |
10KVA/9000W |
20KVA/18KW |
30KVA/27KW |
40KVA/36KW |
Input |
Nominal Voltage |
380/400/415Vac |
Voltage Range |
207-475VAC(3P4W+G) |
Current |
14A |
28A |
42A |
67A |
Frequency |
40-70Hz (Adjustable) |
Power Factor |
≥0.99 |
Output |
Voltage |
380VAC 1±1% (3P4W+G) |
Frequency |
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz -54-60Hz);50Hz(Battery mode) |
Current |
15A |
30A |
45A |
61A |
Power Factor |
0.9 |
Crest Factor |
3:1 |
THD |
Line load <3% |
Chrage Current |
5.5A |
1A |
7.5A |
1A |
5.5A |
Battery Nominal Voltage |
192VDC |
±192VDC |
Transfer Time |
0ms |
Overload Capacity |
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass |
Communication |
SNMP,RS-232,USB+lntelligent Slot |
Operating Environment |
Temperature |
0°C~40°C |
Humidity |
20%~95% |
Dimension |
Width (mm) |
260 |
260 |
260 |
260 |
Depth (mm) |
560 |
533 |
710 |
560 |
Height (mm) |
717 |
501 |
717 |
717 |
Net Weight(Kg) |
26 |
72 |
57.5 |
98 |
58.5 |
62 |
| Features:
- True double-conversion
- LCD screen auto-rotation with Rack position ( only for 10K-20K models)
- DSP technology guarantees high performance
- Output power factor 1
- Support 1/1;3/1;3/3 Phase Adjustable
- Active power factor correction in all phases
- 50HZ / 60HZ frequency converter mode
- ECO mode operation for energy saving ( ECO)
- Emergency power off function ( EPO)
- Generator compatible
- Supports dual AC inputs
- 3-stage extendable charging design for optimized battery performance
- Adjustable battery numbers for long-run model
- Supporting Parallel sharing of battery packs
- Optional isolation transformer offers full isolation and complete common mode noise rejection
- Support with SNMP,USB, RS232 communication
Technical Specifications
MODEL |
33RM 10KL |
33RM 15KL |
33RM 20KL |
33RM 30KL |
33RM 40KL |
33RM 60KL |
CAPACITY |
10KVA/10KW |
15KVA/15KW |
20KVA/20KW |
30KVA/30KW |
40KVA/40KW |
60KVA/60KW |
PHASE |
3 Phase input / 3 Phase output |
PARALLEL CAPABILITY |
4 Max |
INPUT |
Nominal Voltage |
3×380 VAC (3Ph+N) |
Voltage Range |
190-520 VAC (3 Phase) @ 50% load , 305-478 VAC (3 Phase) @ 100% load |
Frequency Range |
46-54 Hz or 56~64Hz |
Power Factor |
≥ 0.99 @ 100% load |
OUTPUT |
Output Voltage |
3 x 360*/380/400/415 VAC (3Ph+N) |
AC Voltage Regulation (Batt. Mode) |
± 1% |
Frequency Range (Synchronized Range) |
46~54Hz or 56~64Hz |
Frequency Range (Batt. Mode) |
50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz |
Current Crest Ratio |
3:1 (max.) |
Harmonic Distortion |
≤1 % THD (Linear Load), ≤3% THD (Non-linear Load) |
Transfer Time |
AC mode to Battery mode |
zero |
Inverter to Bypass |
zero |
Waveform (Batt. Mode) |
Pure Sine Wave |
Overload |
AC Mode |
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection |
Battery Mode |
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection |
EFFICIENCY |
AC Mode |
95.5% |
ECO Mode |
98.5% |
Battery Mode |
94.5% |
BATTERY |
Battery Type |
Depending on the applications |
Numbers |
20 pcs |
32-40 pcs (Adjustable) |
Charging Current (max.) |
1A~ 12A (Adjustable) |
1A~ 16A (Adjustable) |
1A 〜18A (Adjustable) |
Charging Voltage |
±13.65 VDCx N (N=10) |
±13.65VxN (N=16〜20) |
PHYSICAL |
Dimension, D * W * H (mm) |
680*438*133 [3U] |
797*438*176 [4U] |
Net Weight (kgs) |
27 |
30 |
40 |
45 |
ENVIRONMENT |
Operation Temperture |
0-40°C |
Operation Humidity |
0-95% and non-condersing |
Noise Level |
Less than 62dB @ 1 Meter |
Less than 65dB @ 1 Meter |
Less than 70dB @ 1 Meter |
MANAGEMENT |
Smart RS-232/USB |
Supports Windows® Family, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browser |
| Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Specifications
MODEL |
LF33 10K |
LF33 20K |
LF33 30K |
LF33 40K |
LF33 60K |
LF33 80K |
LF33 100K |
LF33 120K |
LF33 160K |
LF33 200K |
CAPACITY |
10KVA /8KW |
20KVA /16KW |
30KVA /24KW |
40KVA /32KW |
60KVA /48KW |
80KVA /64KW |
100KVA /80KW |
120KVA /96KW |
160KVA /128KW |
200KVA /160KW |
INPUT |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Acceptable Voltage Range |
305VAC ~ 460VAC |
Frequency |
46-54Hzor56-64Hz |
INVERTER |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Precision |
Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) |
Frequency |
50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load) ; <5% (Non-linear Load) |
Phase Displacement |
120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load) |
Dynamic Recovery Time |
Restore to 90% of rated value in 3 cycles |
Overload capacity |
110% for 10min; 150% for 60sec; >160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ 100% Unbalanced Load |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
Type |
Solid state |
Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Frequency |
50/60 Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissible Overload |
150% for 1 hour; 180% for 30sec; >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
Type |
Without interruption |
Voltage |
3 * 400V (3Ph + N) |
Frequency |
50/60 Hz |
Overall Efficiency |
Line Mode |
90% |
91% |
92% |
93% |
Battery Mode |
90% |
91% |
93% |
93% |
BATTERY & CHARGER |
Battery Type and Numbers |
12VDC * 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Max.: 40 A |
Charging Voltage |
432 VDC (Based on 32pcs batteries) |
PHYSICAL |
Dimensions, D x W x H(mm) |
656 x 405 x 817 |
656 x 405 x 941 |
840x432x1140 |
975x554x1286 |
1200x910x1680 |
1500x1140x1800 |
Net Weight (Kgs) |
180 |
205 |
295 |
330 |
451 |
519 |
950 |
1350 |
| Features:
- 60KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Technical Specifications
MODEL |
RM Pro 120K |
RM Pro 180K |
RM Pro 300K |
RM Pro 420K |
RM Pro 480K |
RM Pro 600K |
Phase |
3 Phase in / 3 Phase out |
Cabinet Capacity* |
120 KW |
180 KW |
300KW |
420KW |
480KW |
600KW |
Battery Type |
Extemal Battery |
One Power Module Capacity |
60KVA/60KW |
Max. Power Module No. |
2 |
3 |
5 |
7 |
8 |
10 |
INPUT |
Nominal Voltage |
3×380/400/415 VAC(3Ph+N) |
Voltage Range |
-30%~+20% |
Nominal Frequency |
50/60Hz(Auto Sensing) |
Frequency Range |
40Hz~70Hz |
Power Factor |
>0.99 @100% Load, >0.98 @ 50% Load |
Harmonic Distortion (THDi) |
<3%@ 100% load |
OUTPUT |
Nominal Voltage |
3×380/400/415 VAC (3Ph+N) |
Voltage Regulation(Steady State) |
≤±1% Typical(balanced load); ≤±2% Typical(unbalanced load) |
Nominal Frequency |
50/60Hz |
Frequency Range(Synchronized) |
46Hz~54Hz or 56Hz~64Hz |
Overload Capability |
1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150% |
Haronic Distortion |
≤2% THD (Linear Load); ≤4% THD (Non-linear Load) |
Eficiency |
96% |
BATTERY / CHARGER |
Nominal Voltage |
’+/- 192V~+/- 240V(Selectable) |
Maximum Voltage |
’+/- 240V (12V×40 PCS) |
Minimum Voltage |
‘+/-192V (12V×32 PCS) |
Floating Charge Voltage |
2.28V/Cell (2.25~2.33 Selectable) |
Boost Charging Voltage |
2.35V/Cell |
Temperature Compensation |
Yes |
Maximum Charging Current
(Per Power Module) |
18A(Adjustable) |
PHYSICAL |
Cabinet Dimension (DxWxH)mm |
1100x600x1475 |
1100x600x1475 |
1100x600x2010 |
1100×600×2010 |
1065x1000x2000 |
1065×1000×2000 |
Net Weight (Kg) |
308 |
352 |
516 |
654 |
932 |
1020 |
Power Module (PM-60) Net Weight |
44KGS |
ENVIRONMENT |
Operating Temperature |
0~40℃ |
Relative Humidity |
0~95% non-condensing |
Altitude* |
<1000m for Nominal power |
IP Protection |
IP 20 |
MANAGEMENT |
Smart RS-232/USB |
Supports Windows⑧ Family, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browser |
STANDARDS |
Safety |
IEC/EN62040-1 |
EMC |
IEC/EN 62040-2 Category C3 |
| Features:
- 50KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Specifications:
MODEL |
RM Plus 300K |
RM Plus 350K |
RM Plus 400K |
RM Plus 500K |
Phase |
3 Phase in / 3 Phase out |
Cabinet Capacity* |
300 KW |
350 KW |
400KW |
500KW |
Battery Type |
Extemal Battery |
One Power Module Capacity |
50KVA/50KW |
Max. Power Module No. |
6 |
7 |
8 |
10 |
INPUT |
Nominal Voltage |
3×380/400/415 VAC (3Ph+N) |
Voltage Range |
’-20%~+15% |
Nominal Frequency |
50/60Hz(Auto Sensing) |
Frequency Range |
40Hz~70Hz |
Power Factor |
>0.99 @100% Load, >0.98@50% Load |
Harmonic Distortion (THDi) |
<4% @ 100% load |
OUTPUT |
Nominal Voltage |
3×380/400/415 VAC (3Ph+N) |
Voltage Regulation(Steady State) |
≤ ±1% Typical (balanced load); ~≤ ±2% Typical (unbalanced load) |
Nominal Frequency |
50/60Hz |
Frequency Range(Synchronized) |
46Hz~54Hz or 56Hz~64Hz |
Overload Capability |
1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150% |
Haronic Distortion |
≤2% THD (Linear Load); ≤4% THD (Non-linear Load) |
Eficiency |
95.50% |
BATTERY / CHARGER |
Nominal Voltage |
‘+/- 192V~+/- 240V (Selectable) |
Maximum Voltage |
’+/- 240V (12V×40PCS) |
Minimum Voltage |
‘+/- 192V(12V×32PCS) |
Floating Charge Voltage |
2.28V/Cell (2.25~2.33 Selectable) |
Boost Charging Voltage |
2.35V/Cell |
Temperature Compensation |
Yes |
Maximum Charging Current
(Per Power Module) |
12A (Adjustable) |
PHYSICAL |
Cabinet Dimension (DxWxH)mm |
1065x600x2000 |
1065x600x2000 |
1065x1000x2000 |
1065x1000x2000 |
Net Weight (Kg) |
545 |
654 |
932 |
1020 |
Power Module (PM-50) Net Weight |
44KGS |
ENVIRONMENT |
Operating Temperature |
0~40℃ |
Relative Humidity |
0~95% non-condensing |
Altitude* |
<1000m for Nominal power |
IP Protection |
IP 20 |
MANAGEMENT |
Smart RS-232/USB |
Supports Windows⑧ Family, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browser |
STANDARDS |
Safety |
IEC/EN 62040-1 |
EMC |
IEC/EN 62040-2 Category C3 |
|
Reviews