Portable Power Generator PS Series 1200W

$0.00

Shipped From Abroad

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130139-19
Brands:: Reeco Power

Description

Features:
  • Capacity: 1200W 1008Wh /315000mAh
  • Input AC Output Power:Rated Power 1200W Peak Power 2400W
  • Input AC Charging:AC100~125V/AC184~264V Bidirectional Inverter 700W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC12V~60V/10A 400W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*5V2.4A +2*QC18W+2*PD60W Max
  • DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support(≤10mS)

 

Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms

Reviews

There are no reviews yet.

Be the first to review “Portable Power Generator PS Series 1200W”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPortable Power Generator PS Series 1200W remove3 Phase Low Frequency Online UPS LD31 Series remove3 Phase Low Frequency Online UPS LD33 Series removeHigh Frequency Rack Mount UPS 33RM Series removePortable Power Generator PS Series 600W removeHigh Frequency Modular UPS RM Plus Series 300 KW-500KW remove
NamePortable Power Generator PS Series 1200W remove3 Phase Low Frequency Online UPS LD31 Series remove3 Phase Low Frequency Online UPS LD33 Series removeHigh Frequency Rack Mount UPS 33RM Series removePortable Power Generator PS Series 600W removeHigh Frequency Modular UPS RM Plus Series 300 KW-500KW remove
Image
SKUSF1033560130139-19SF1033560130139-2SF1033560130139-3SF1033560130139-12SF1033560130139-20SF1033560130139-8
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • 50KW single power module in 3U
  • N+1or N+X parallel redundancy for power guarantee
  • Supports horizontal expansion by 1+1 cabinet paralleloperation.
  • Hot-swappable modular design decreases MTTR
  • High scalability
  • Built-in maintenance bypass switch for easy maintenance without interruptible
  • High efficiency double conversion online UPS
  • Flexible battery configuration and adjustable charging current
  • High overload capability
  • Power walk-in function
  • Built-in dynamic password protection
  • Built-in ultra communication slot
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • Capacity: 1200W 1008Wh /315000mAh
  • Input AC Output Power:Rated Power 1200W Peak Power 2400W
  • Input AC Charging:AC100~125V/AC184~264V Bidirectional Inverter 700W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC12V~60V/10A 400W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*5V2.4A +2*QC18W+2*PD60W Max
  • DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support(≤10mS)
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY IGBT Technology Full microprocessor control with no-break static and manual bypasses. Online double conversion technology (VFl) with isolation transformer on theinverter output. Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. SIMPLE TO INSTALL Capability to install the UPS into any distribution system(neutral not required on rectifier input). Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer MAXIMUM BATTERY CARE Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature. OTHER CHARACTERISTICS 0.8/0.9 power factor suitable for powering ICT and lndustrial loads. BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur. MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP) LOW CONSUMPTION LEVELS LF31 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail. ADVANCE COMMUNICATION: RS485/RS232/Dry Contact/SNMP(Optional)  
Specifications
Model 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA    80KVA 100KVA
Capacity 8KW 12 KW 16 KW 24 KW 32 KW 48 KW    64 KW    80 KW
INPUT
Rated voltage 380/400/415 VAC  Three-phase
Voltage range ±20%
Frequency range 45-65Hz
Power factor >0.92 with harmonic filter
Current harmonic distortion <5% with harmonic filter
Soft Start 0 -100% in 10″
BYPASS INPUT
Rated voltage 230VAC   Single Phase
Permitted voltage range ±15%  (selectable from ±10% to ±25% from front panel)
Rated frequency 50/60Hz
Permitted frequency range ±2%    (selectable from ±1% to ±5% from front panel)
Standard features Back Feed portection; split bypass line
BATTERY
Type VRLA AGM / GEL;NICd
Battery Voltage 384VDC
Maximum recharge current(A) 0.2 X C10
AC ripple voltage <1%
INVERTER OUTPUT
Rated power(kVA) 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA     80KVA 100KVA
Active power(kW)  8KW 12 KW 16 KW 24 KW 32 KW 48 KW     64 KW 80 KW
Number of phases 1
Rated voltage(V) 230VAC  Single Phase
Regulation of the output voltage 220 ~ 244VAC  phase/neutral (from control panel)
Crest factor(Ipeak/Irms) 3:1
Static stability ±1%
Dynamic stability ±5%
Frequency 50/60Hz configurable
Overload 110% 125% 150% of the rated current for 5h/10’/1′
Frequency stability ±0.05% on mains failure
System 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA     80KVA 100KVA
Remote signaling Volt free contacts
Remote controls EPO and Bypass
Communication RS232 + Romote Contacts
Operation temperature 0℃ to  ~ 40℃
Relative humidity <95% non condensing
Colour Light grey ( RAL 7035)
Noise 54dBA at 1m 60dBA at 1m   65dBA at 1m
Protection degree IP20
Efficiency Smart Mode Up to 98%
Compliance Safety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive 2004/108/EC)
Weight(KG)N.W 176 220 205 213 295 440 520 770
Dimensions:(WxDxH)mm 555*730*1210 800*730*1400 1115*730*1400
Internal batteries optional optional optional No      No No No No
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY IGBT Technology Full microprocessor control with no-break static and manual bypasses. Online double conversion technology (VFl) with isolation transformer on theinverter output. Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. SIMPLE TO INSTALL Capability to install the UPS into any distribution system(neutral not required on rectifier input). Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer MAXIMUM BATTERY CARE Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature. OTHER CHARACTERISTICS 0.8/0.9 power factor suitable for powering ICT and lndustrial loads. BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur. MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP) LOW CONSUMPTION LEVELS LF33 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail. ADVANCE COMMUNICATION: RS485/RS232/Dry Contact/SNMP(Optional)  
Specifications
Model 10KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA 250KVA 300KVA 400KVA 500KVA 600KVA
Capacity 8KW 16 KW 24 KW 32 KW  48 KW 64 KW  80 KW 96 KW 128 KW 160 KW 200KW 240KW 320KW 400KW  480KW
INPUT
Rated voltage 400 VAC  Three-Phase
Voltage range 380/400/415VAC(+25%,Can be set through the LCD panel)
Frequency range 40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ) 50±5%(±10%) Bypass synchronization tracking
Rectifying pulse number 6 pulse rectification 6/12 pulse rectification 12 pulse rectifier
Phase system 3φ4W+PE(Three phase five wire system)
Battery voltage 384VDC 480VDC
Battery Quantity Standard with 32 Cells(30~34, can be set through the LCD panel)  Standard 40 Cells(38~42 knots,can be set by LCD panel)
OUTPUT
Power factor 0.8/0.9 (Optional)
Voltage(V) L-N: 220±1%   L-L: 380±1%
Three-phase 100% load unbalance voltage stability ≤2%,Allow 100% imbalance
Frequency(HZ) Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms) 0ms
Parallel operation mode (parallel type) Max 8 Parallel
Waveform distortion Linear loadTHD<3% ; Nonlinear loadTHD<5%
Overload capacity 125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply, after reducing the loadcan automatically restore the inverter
Crest factor 3:1
Others
Index Standard with no transfer time maintenance bypass switch
Communication function RS232/RS485/Dry Contact/SNMP (Optional)
Panel display LED displays working status and fault indication; LCD displays three-phase input voltage, input frequency, three-phase output voltage, load,battery voltage, battery charge and discharge current, etc
Display  7″ Touchable LCD screen display
The audio noise(dB) <65(within 1 meter)
Alarm function Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Cooling way Forced cooling
Operating temperature 0℃ to  ~ 40℃
Humidity 0~95%, non-condensing
electromagnetic compatibility Conform GB7260.2
Size(W*D*H)(mm) 540*660*1135 1100*800*1800 800*800*1900 1200*850*1900 2600*1100*2000
Weight 196     233 276 329 461 547.5 643 754 1375
Features:
  • True double-conversion
  • LCD screen auto-rotation with Rack position ( only for 10K-20K models)
  • DSP technology guarantees high performance
  • Output power factor 1
  • Support 1/1;3/1;3/3 Phase Adjustable
  • Active power factor correction in all phases
  • 50HZ / 60HZ frequency converter mode
  • ECO mode operation for energy saving ( ECO)
  • Emergency power off function ( EPO)
  • Generator compatible
  • Supports dual AC inputs
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery numbers for long-run model
  • Supporting Parallel sharing of battery packs
  • Optional isolation transformer offers full isolation and complete common mode noise rejection
  • Support with SNMP,USB, RS232 communication
 
Technical Specifications
MODEL 33RM 10KL 33RM 15KL 33RM 20KL 33RM 30KL 33RM 40KL 33RM 60KL
CAPACITY 10KVA/10KW 15KVA/15KW 20KVA/20KW 30KVA/30KW 40KVA/40KW 60KVA/60KW
PHASE 3 Phase input / 3 Phase output
PARALLEL CAPABILITY 4 Max
INPUT
Nominal Voltage 3×380 VAC (3Ph+N)
Voltage Range 190-520 VAC (3 Phase) @ 50% load , 305-478 VAC (3 Phase) @ 100% load
Frequency Range 46-54 Hz or 56~64Hz
Power Factor ≥ 0.99 @ 100% load
OUTPUT
Output Voltage 3 x 360*/380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤1 % THD (Linear Load), ≤3% THD (Non-linear Load)
Transfer Time AC mode to Battery mode zero
Inverter to Bypass zero
Waveform (Batt. Mode) Pure Sine Wave
Overload AC Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
Battery Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
EFFICIENCY
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
BATTERY
Battery Type Depending on the applications
Numbers 20 pcs 32-40 pcs (Adjustable)
Charging Current (max.) 1A~ 12A (Adjustable) 1A~ 16A (Adjustable) 1A 〜18A (Adjustable)
Charging Voltage ±13.65 VDCx N (N=10) ±13.65VxN (N=16〜20)
PHYSICAL
Dimension, D * W * H (mm) 680*438*133 [3U] 797*438*176 [4U]
Net Weight (kgs) 27 30 40 45
ENVIRONMENT
Operation Temperture 0-40°C
Operation Humidity 0-95% and non-condersing
Noise Level Less than 62dB @ 1 Meter Less than 65dB @ 1 Meter Less than 70dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Features:
  • Capacity: 600W 512Wh /160000mAh
  • Input AC Output Power:Rated Power 600W Peak Power 1200W
  • Input AC Charging:AC100~120V/AC200~240V Built-in 200W
  • Input Car Charging:DC12V~24V/7A Max 120W Max
  • Input Solar Charging:DC12V~24V/120WMax
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*QC24W+PD27W+PD100W Max
  • DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support(≤10mS)
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
  • 50KW single power module in 3U
  • N+1or N+X parallel redundancy for power guarantee
  • Supports horizontal expansion by 1+1 cabinet paralleloperation.
  • Hot-swappable modular design decreases MTTR
  • High scalability
  • Built-in maintenance bypass switch for easy maintenance without interruptible
  • High efficiency double conversion online UPS
  • Flexible battery configuration and adjustable charging current
  • High overload capability
  • Power walk-in function
  • Built-in dynamic password protection
  • Built-in ultra communication slot
 
Specifications:
MODEL RM Plus 300K RM Plus 350K RM Plus 400K RM Plus 500K
Phase 3 Phase in / 3 Phase out
Cabinet Capacity* 300 KW 350 KW 400KW 500KW
Battery  Type Extemal Battery
One Power Module Capacity 50KVA/50KW
Max.   Power Module  No. 6 7 8 10
INPUT
Nominal Voltage 3×380/400/415 VAC (3Ph+N)
Voltage Range ’-20%~+15%
Nominal Frequency 50/60Hz(Auto Sensing)
Frequency Range 40Hz~70Hz
Power Factor >0.99  @100%  Load, >0.98@50%  Load
Harmonic  Distortion   (THDi) <4% @ 100%  load
OUTPUT
Nominal Voltage 3×380/400/415 VAC (3Ph+N)
Voltage  Regulation(Steady  State) ≤ ±1% Typical (balanced load); ~≤ ±2% Typical (unbalanced load)
Nominal Frequency 50/60Hz
Frequency Range(Synchronized) 46Hz~54Hz or 56Hz~64Hz
Overload Capability 1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150%
Haronic Distortion ≤2% THD (Linear Load); ≤4% THD (Non-linear Load)
Eficiency 95.50%
BATTERY / CHARGER
Nominal Voltage ‘+/- 192V~+/- 240V (Selectable)
Maximum Voltage ’+/- 240V (12V×40PCS)
Minimum Voltage ‘+/- 192V(12V×32PCS)
Floating Charge Voltage 2.28V/Cell (2.25~2.33 Selectable)
Boost Charging Voltage 2.35V/Cell
Temperature Compensation Yes
Maximum Charging Current (Per Power Module) 12A (Adjustable)
PHYSICAL
Cabinet Dimension (DxWxH)mm 1065x600x2000 1065x600x2000 1065x1000x2000 1065x1000x2000
Net Weight (Kg) 545 654 932 1020
Power Module (PM-50) Net Weight 44KGS
ENVIRONMENT
Operating Temperature 0~40℃
Relative Humidity 0~95% non-condensing
Altitude* <1000m for Nominal power
IP  Protection IP 20
MANAGEMENT
Smart  RS-232/USB Supports Windows⑧ Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
STANDARDS
Safety IEC/EN 62040-1
EMC IEC/EN 62040-2 Category C3
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare