Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Intelligent CPU control
- Automatic power on when the the main power recovers
- Cold start function
- Power off charging function
- USB/RS232/RJ-11/RJ-45 communication port (optional)
- Offering LED and LCD panels for selection
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- 60KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- The battery cabinet is made of metal material, strong and can bear up to 500KG.
- The battery cabinet is assembled in the form of assembly, which is conven-ient for transportation and simple for assembly.
- The surface of electrostatic spraying, strong rust resistance, color can be fixed spray.
- Other sizes can be customized.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | Features:
- Capacity: 2200W 2048Wh /640000mAh
- Input AC Output Power:Rated Power 2400W Peak Power 4800W
- Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
- Input Car Charging:DC12V~24V/10A 240W Max
- Input Solar Charging:DC16V~60V/10A 500W Max
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*QC18W+PD27W+PD100W Max
- DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support ; Battery Expandable: Support
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
| Features:
- Intelligent CPU control
- Automatic power on when the the main power recovers
- Cold start function
- Power off charging function
- USB/RS232/RJ-11/RJ-45 communication port (optional)
- Offering LED and LCD panels for selection
Application:
- Personal Computer
- Printer
- POS(Point of sales)Terminals
- Security System
- Fax Machine
- Modem, WiFi Router
Technical Specifications:
Model |
DP600 |
DP1000 |
DP1200 |
DP2000 |
DP3000 |
Capacity |
600VA/360W |
1000VA/600W |
1200VA/720W |
2000VA/1200W |
3000VA/1800W |
INPUT |
Voltage |
110/120VAA or 220/230/240VAC |
Voltage Range |
67-137VAC/135-275VAC |
Frequency Range |
50Hz Or 60Hz(Auto-Sensing) |
OUTPUT |
Output Voltage |
110/120VAA or 220/230/240VAC |
AC Voltage Regulation |
± 10% |
Frequency Range
(Batt. Mode) |
50 HZ or 60 Hz ± 10% |
Transfer Time |
Typical 6-10 ms |
Waveform
(Battery Mode) |
Simulated Sine Wave |
BATTERY |
Battery Voltage |
12V/7AH*1 |
12V/9AH*1 |
12V/7AH*2 |
12V/9AH*2 |
12V/7AH*4 |
Charge Time |
8 hours up to 80-90% |
PROTECTION |
Full Protection |
Auto Detection, discharge protection,output Short circuit, Over load, Battery low voltage protection |
Communication Port |
USB/RS232/RJ11/RJ45 (Optional) |
Display |
LED/LCD |
Alarm |
Battery Mode |
Every 4 Seconds one beep |
Low Battery Capacity |
Every 1 Seconds one beep |
Overload |
Every 1 Seconds one beep |
Fault |
Keep beeping |
ENVIRONMENT |
Humidity |
0-90% Rh @ 0-40℃ (Non-Condensing) |
Noise Level |
40dB |
Dimension(mm) |
320*90*140 |
330* 100*150 |
365*140*165 |
365*140*165 |
395*145*210 |
N.W.(kg) |
5.2 |
6 |
10 |
12.6 |
21 |
| Features:
- 60KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Technical Specifications
MODEL |
RM Pro 120K |
RM Pro 180K |
RM Pro 300K |
RM Pro 420K |
RM Pro 480K |
RM Pro 600K |
Phase |
3 Phase in / 3 Phase out |
Cabinet Capacity* |
120 KW |
180 KW |
300KW |
420KW |
480KW |
600KW |
Battery Type |
Extemal Battery |
One Power Module Capacity |
60KVA/60KW |
Max. Power Module No. |
2 |
3 |
5 |
7 |
8 |
10 |
INPUT |
Nominal Voltage |
3×380/400/415 VAC(3Ph+N) |
Voltage Range |
-30%~+20% |
Nominal Frequency |
50/60Hz(Auto Sensing) |
Frequency Range |
40Hz~70Hz |
Power Factor |
>0.99 @100% Load, >0.98 @ 50% Load |
Harmonic Distortion (THDi) |
<3%@ 100% load |
OUTPUT |
Nominal Voltage |
3×380/400/415 VAC (3Ph+N) |
Voltage Regulation(Steady State) |
≤±1% Typical(balanced load); ≤±2% Typical(unbalanced load) |
Nominal Frequency |
50/60Hz |
Frequency Range(Synchronized) |
46Hz~54Hz or 56Hz~64Hz |
Overload Capability |
1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150% |
Haronic Distortion |
≤2% THD (Linear Load); ≤4% THD (Non-linear Load) |
Eficiency |
96% |
BATTERY / CHARGER |
Nominal Voltage |
’+/- 192V~+/- 240V(Selectable) |
Maximum Voltage |
’+/- 240V (12V×40 PCS) |
Minimum Voltage |
‘+/-192V (12V×32 PCS) |
Floating Charge Voltage |
2.28V/Cell (2.25~2.33 Selectable) |
Boost Charging Voltage |
2.35V/Cell |
Temperature Compensation |
Yes |
Maximum Charging Current
(Per Power Module) |
18A(Adjustable) |
PHYSICAL |
Cabinet Dimension (DxWxH)mm |
1100x600x1475 |
1100x600x1475 |
1100x600x2010 |
1100×600×2010 |
1065x1000x2000 |
1065×1000×2000 |
Net Weight (Kg) |
308 |
352 |
516 |
654 |
932 |
1020 |
Power Module (PM-60) Net Weight |
44KGS |
ENVIRONMENT |
Operating Temperature |
0~40℃ |
Relative Humidity |
0~95% non-condensing |
Altitude* |
<1000m for Nominal power |
IP Protection |
IP 20 |
MANAGEMENT |
Smart RS-232/USB |
Supports Windows⑧ Family, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browser |
STANDARDS |
Safety |
IEC/EN62040-1 |
EMC |
IEC/EN 62040-2 Category C3 |
| Features:
- The battery cabinet is made of metal material, strong and can bear up to 500KG.
- The battery cabinet is assembled in the form of assembly, which is conven-ient for transportation and simple for assembly.
- The surface of electrostatic spraying, strong rust resistance, color can be fixed spray.
- Other sizes can be customized.
Technical Specifications
| Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Specifications
MODEL |
LF33 10K |
LF33 20K |
LF33 30K |
LF33 40K |
LF33 60K |
LF33 80K |
LF33 100K |
LF33 120K |
LF33 160K |
LF33 200K |
CAPACITY |
10KVA /8KW |
20KVA /16KW |
30KVA /24KW |
40KVA /32KW |
60KVA /48KW |
80KVA /64KW |
100KVA /80KW |
120KVA /96KW |
160KVA /128KW |
200KVA /160KW |
INPUT |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Acceptable Voltage Range |
305VAC ~ 460VAC |
Frequency |
46-54Hzor56-64Hz |
INVERTER |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Precision |
Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) |
Frequency |
50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load) ; <5% (Non-linear Load) |
Phase Displacement |
120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load) |
Dynamic Recovery Time |
Restore to 90% of rated value in 3 cycles |
Overload capacity |
110% for 10min; 150% for 60sec; >160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ 100% Unbalanced Load |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
Type |
Solid state |
Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Frequency |
50/60 Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissible Overload |
150% for 1 hour; 180% for 30sec; >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
Type |
Without interruption |
Voltage |
3 * 400V (3Ph + N) |
Frequency |
50/60 Hz |
Overall Efficiency |
Line Mode |
90% |
91% |
92% |
93% |
Battery Mode |
90% |
91% |
93% |
93% |
BATTERY & CHARGER |
Battery Type and Numbers |
12VDC * 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Max.: 40 A |
Charging Voltage |
432 VDC (Based on 32pcs batteries) |
PHYSICAL |
Dimensions, D x W x H(mm) |
656 x 405 x 817 |
656 x 405 x 941 |
840x432x1140 |
975x554x1286 |
1200x910x1680 |
1500x1140x1800 |
Net Weight (Kgs) |
180 |
205 |
295 |
330 |
451 |
519 |
950 |
1350 |
| Features:
- Capacity: 600W 512Wh /160000mAh
- Input AC Output Power:Rated Power 600W Peak Power 1200W
- Input AC Charging:AC100~120V/AC200~240V Built-in 200W
- Input Car Charging:DC12V~24V/7A Max 120W Max
- Input Solar Charging:DC12V~24V/120WMax
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*QC24W+PD27W+PD100W Max
- DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support(≤10mS)
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
|
Reviews
There are no reviews yet.