Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- 60KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
1)19 inches standard design of rack mount, compact structure.
2)Sin wave output provides best power supply guarantee.
3)Zero transfer time between mains mode and battery mode.
4)Detection function of input neutral wire and live wire.
5)Having voltage surge protection function and strong anti-interference function.
6)Equipped with correction function of input power factor
7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Valve sealed design, no free electrolyte, Maintenance -free
- Designed floating service life:15 years @ 25 °C/68 °F.
- Wide operating temperature range from -15°C to 35°C
- Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
- Low self-discharge rate: ≤3%/month.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Pure sine wave output
- DSP digital control
- Boost and buck AVR for voltage stabilization
- Cold start function
- Intelligent battery management
- Short circuit and overload protection
- Off-mode charging
- Offering LED and LCD panels for selection
- Optional USB/RS232/RJ45/SNMP communication port
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | Features:
- Capacity: 2200W 2048Wh /640000mAh
- Input AC Output Power:Rated Power 2400W Peak Power 4800W
- Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
- Input Car Charging:DC12V~24V/10A 240W Max
- Input Solar Charging:DC16V~60V/10A 500W Max
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*QC18W+PD27W+PD100W Max
- DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support ; Battery Expandable: Support
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
| Features:
- 60KW single power module in 3U
- N+1or N+X parallel redundancy for power guarantee
- Supports horizontal expansion by 1+1 cabinet paralleloperation.
- Hot-swappable modular design decreases MTTR
- High scalability
- Built-in maintenance bypass switch for easy maintenance without interruptible
- High efficiency double conversion online UPS
- Flexible battery configuration and adjustable charging current
- High overload capability
- Power walk-in function
- Built-in dynamic password protection
- Built-in ultra communication slot
Technical Specifications
MODEL |
RM Pro 120K |
RM Pro 180K |
RM Pro 300K |
RM Pro 420K |
RM Pro 480K |
RM Pro 600K |
Phase |
3 Phase in / 3 Phase out |
Cabinet Capacity* |
120 KW |
180 KW |
300KW |
420KW |
480KW |
600KW |
Battery Type |
Extemal Battery |
One Power Module Capacity |
60KVA/60KW |
Max. Power Module No. |
2 |
3 |
5 |
7 |
8 |
10 |
INPUT |
Nominal Voltage |
3×380/400/415 VAC(3Ph+N) |
Voltage Range |
-30%~+20% |
Nominal Frequency |
50/60Hz(Auto Sensing) |
Frequency Range |
40Hz~70Hz |
Power Factor |
>0.99 @100% Load, >0.98 @ 50% Load |
Harmonic Distortion (THDi) |
<3%@ 100% load |
OUTPUT |
Nominal Voltage |
3×380/400/415 VAC (3Ph+N) |
Voltage Regulation(Steady State) |
≤±1% Typical(balanced load); ≤±2% Typical(unbalanced load) |
Nominal Frequency |
50/60Hz |
Frequency Range(Synchronized) |
46Hz~54Hz or 56Hz~64Hz |
Overload Capability |
1 hour for ≤110%,10 mins for 111%~125%,1 min for 126%~150% and 200ms for >150% |
Haronic Distortion |
≤2% THD (Linear Load); ≤4% THD (Non-linear Load) |
Eficiency |
96% |
BATTERY / CHARGER |
Nominal Voltage |
’+/- 192V~+/- 240V(Selectable) |
Maximum Voltage |
’+/- 240V (12V×40 PCS) |
Minimum Voltage |
‘+/-192V (12V×32 PCS) |
Floating Charge Voltage |
2.28V/Cell (2.25~2.33 Selectable) |
Boost Charging Voltage |
2.35V/Cell |
Temperature Compensation |
Yes |
Maximum Charging Current
(Per Power Module) |
18A(Adjustable) |
PHYSICAL |
Cabinet Dimension (DxWxH)mm |
1100x600x1475 |
1100x600x1475 |
1100x600x2010 |
1100×600×2010 |
1065x1000x2000 |
1065×1000×2000 |
Net Weight (Kg) |
308 |
352 |
516 |
654 |
932 |
1020 |
Power Module (PM-60) Net Weight |
44KGS |
ENVIRONMENT |
Operating Temperature |
0~40℃ |
Relative Humidity |
0~95% non-condensing |
Altitude* |
<1000m for Nominal power |
IP Protection |
IP 20 |
MANAGEMENT |
Smart RS-232/USB |
Supports Windows⑧ Family, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browser |
STANDARDS |
Safety |
IEC/EN62040-1 |
EMC |
IEC/EN 62040-2 Category C3 |
| Features:
1)19 inches standard design of rack mount, compact structure.
2)Sin wave output provides best power supply guarantee.
3)Zero transfer time between mains mode and battery mode.
4)Detection function of input neutral wire and live wire.
5)Having voltage surge protection function and strong anti-interference function.
6)Equipped with correction function of input power factor
7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.
Technical Specifications
Model |
RTX3110KL |
RTX3115KL |
RTX3120KL |
Rated Power |
10kVA/9kW |
15kVA/13.5kW |
20kVA/18kW |
INPUT |
Voltage Range |
207-475Vac3P4W+G |
Working Frequency Range |
40-70HZ (settable) |
Input Power Factor |
>0.95 |
OUTPUT |
Rated Voltage and Accuracy |
220Vac(l±l%)lP2W+G |
Output Frequency |
46-54Hz synchronize with mains power; 50Hz (Mains power between 40-46Hz and 54-60Hz); 50Hz(Battery) |
Rated Current |
45A |
68A |
91A |
Output Power Factor |
0.9 |
Output Harmonic Wave |
W3% |
Crest Factor |
3:1 |
Output Overload |
105%±5%<Load≤125%±5%: Convert to bypass output and alarm after 1 min;
125%±5%<Load ≤50%±5%: Convert to bypass output and alarm after 30s;
Load>150%±5%: Convert to bypass output and alarm after 300ms. |
Transfer Time |
0ms |
Efficiency |
>92% |
BATTERY |
Rated Voltage |
192Vdc |
Quantity |
16 |
Charging Current |
5.5A |
Dimension (LxWxH) mm |
665*482.6*132.5 |
655*482.6*265 |
Weight |
23kg |
34kg |
35kg |
Working Temperature |
0°〜40°C |
Working Humidity |
20% 〜95% |
Noise |
≤60dB |
| Features:
Digital Control
All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is morestableand reliable.Each module has built-in
automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance.
Intelligent Battery Management
Users can set the charging current, constant current, constant voltage and floatingcharging modescan be automatically and smoothly switched; Battery voltage can beset
±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional)
High Power Density Modular Design
The capacity of each single module is30kVA, and the height is3U; UPS modulescan be added and removed onlineto achieve zero maintenance time.
N+x Parallel Redundancy
The quantity of redundant module can be set accordingly, When the redundant module reaches more than 2 hours, the system availability achieves 99.99%,
MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets.
A maximum of four cabinets can be parallel,and battery pack can be shared when UPS cabinet in parallel.
Touchable LCD Display Screen
Super large LCD display with touching function.
Standard Cabinet Design
The appearance ofthe standard cabinet is beautiful and generous, which can perfectly match the use environment ofthe computer room and save the space.
Safe and Easy to Maintain
When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance;
Press EPO button to shutdown in emergentsituation, and also have REPO function.
Intelligent Management
Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMPcard (optional), can realize remote monitoringof UPS, relay card is optional.
Technical Specifications
Model |
VM 90K |
VM150K |
VM300K |
Capacity |
UPS Cabinet |
30-90KVA |
30-150KVA |
30-300KVA |
Power Module |
30kVA |
INPUT |
Input Form |
3P4W+G |
Rated Voltage |
380/400/415Vac |
Voltage Range |
207~478Vac |
Frequency Range |
40~70Hz |
Input Power Factor |
≥0.99 |
Bypass Range |
380 upper limit: 25% (optional +10%s +15%、+20%)
400 upper limit: 20% (optional +10%、+15%)
415 upper limit: 15% (optional +10%) Lower limit: -45% (optional -20%s -30%)
Bypass frequency protection range: ± 10% |
Input Current Harmonic Wave |
≤3% (100% non-linear) |
OUTPUT |
Output Form |
3P4W+G |
Rated Voltage |
380/400/415Vac |
Output Power Factor |
0.9 or 1 |
Voltage Accuracy |
±1% |
Output Frequency |
Mains Mode |
Synchronization with input; when mains frequency exceeds maximum value ±10%
(can be set ±1%、 ±2%、±4%、±5%), output frequency 50X(±0.2%)Hz |
Battery Mode |
(50/60±0.2%) Hz |
Crest Factor |
3:1 |
Conversion Time |
Mains mode — bypass mode: 0ms (tracking); Mains mode— battery mode: 0ms |
Overload Capacity |
Load≤110%: 60 mins;
Load≤125%: 10 mins;
Load≤150%: 1 min;
Load≥150%, shutdown immediately |
Output Voltage Harmonic Wave |
≤2% (100% linear) |
Efficiency |
In normal mode 95% |
Communication Port |
RS232、RS485、 Intelligent Slot*2 、 Dry connect port |
BATTERY |
Battery Voltage |
±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc; (32/34/36/38/40pcs Optional) |
Charging Current |
UPS Cabinet |
30A Max |
50A Max |
100A Max |
Power Module |
10A Max |
Environment |
Operating Temperature |
0〜40°C |
Relative Humidity |
0-95% (non-condensing) |
Storage Temperature |
-25-55°C (excluded battery) |
Altitude |
< 1500m (derating if exceeding 1500m) |
Physical Characteristic |
Outer Dimension (LxWxH) mm |
Cabinet |
840X600X1400 |
1100X600X2000 |
Module |
580 X 443 X 131 |
Weight
(Net Weight) KG |
Cabinet |
158 |
170 |
305 |
Module |
33.5 |
Operative Standard |
YD/T 2165-2010 |
| Features:
- Valve sealed design, no free electrolyte, Maintenance -free
- Designed floating service life:15 years @ 25 °C/68 °F.
- Wide operating temperature range from -15°C to 35°C
- Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
- Low self-discharge rate: ≤3%/month.
Application
- UPS Systems
- Portable Equipment
- Renewable Energy Systems
- Electric Utilities
- Outdoor control Equipment
- Railroad Utilities
- Telecom Systems
Technical Specifications
Model |
Nominal Voltage |
Capacity |
Dimension LXWXH (mm) |
Total Height
(mm) |
Weight (KG/IBS) |
Terminal |
VG12-33 |
12V |
33AH |
195 |
130 |
167 |
167 |
10 |
22.05 |
M6 |
VG12-35 |
12V |
35AH |
195 |
130 |
167 |
167 |
11.5 |
25.35 |
M6 |
VG12-38 |
12V |
38AH |
197 |
165 |
172 |
172 |
12.5 |
27.56 |
M6 |
VG12-40 |
12V |
40AH |
197 |
165 |
172 |
172 |
13.2 |
29.1 |
M6 |
VG12-45 |
12V |
45AH |
197 |
165 |
172 |
172 |
15 |
33.07 |
M6 |
VG12-50 |
12V |
50AH |
229 |
138 |
205 |
208 |
15.5 |
34.17 |
M6 |
VG12-55 |
12V |
55AH |
229 |
138 |
205 |
208 |
16.5 |
36.38 |
M6 |
VG12-65 |
12V |
65AH |
350 |
166 |
175 |
175 |
21 |
46.3 |
M8 |
VG12-70 |
12V |
70AH |
260 |
168 |
208 |
211 |
21.8 |
48.06 |
M8 |
VG12-80 |
12V |
80AH |
260 |
168 |
208 |
211 |
24 |
52.91 |
M8 |
VG12-90 |
12V |
90AH |
330 |
171 |
216 |
219 |
27 |
59.52 |
M8 |
VG12-100 |
12V |
100AH |
330 |
171 |
216 |
219 |
29.5 |
65.04 |
M8 |
VG12-120 |
12V |
120AH |
407 |
173 |
237 |
237 |
35 |
77.16 |
M8 |
VG12-150 |
12V |
150AH |
484 |
170 |
241 |
241 |
45 |
99.21 |
M8 |
VG12-200 |
12V |
200AH |
522 |
240 |
219 |
222 |
61.5 |
135.58 |
M8 |
VG12-250 |
12V |
250AH |
520 |
268 |
220 |
223 |
71 |
156.53 |
M8 |
| Features:
- Pure sine wave output
- DSP digital control
- Boost and buck AVR for voltage stabilization
- Cold start function
- Intelligent battery management
- Short circuit and overload protection
- Off-mode charging
- Offering LED and LCD panels for selection
- Optional USB/RS232/RJ45/SNMP communication port
Technical Specifications
MODEL |
UPS-AP1K ( L ) |
UPS-AP2K ( L ) |
UPS-AP3K ( L ) |
Capacity |
1000VA/700W |
2000VA/1400W |
3000VA/2100W |
INPUT |
Voltage range |
145~275VAC±5V |
Frequency range |
50Hz-60Hz |
OUTPUT |
Output voltage |
220VAC |
AC voltage range |
±10% |
Frequency range(batt.mode) |
50Hz ± 0.25Hz or 60Hz ± 0.3Hz |
Overload |
105%-110%: UPS beep alarm, do not shut down. |
110%-130%: auto shut down after 30 seconds |
> 130%: auto shut down immediately |
Transfer time |
<typical 4ms |
Waveform(batt.mode) |
Pure sine wave |
BATTERY |
Standard model |
Battery type |
12V7Ah |
Numbers |
2 |
4 |
6 |
Charging current(Max.) |
Assume: 1A± 10%; Max: 1A or 2A for option |
Charging voltage |
27.3VDC±1% |
54.7VDC±1% |
82.0VDC±1% |
Long-run model |
Battery type |
12V, AH depending on applicant |
Numbers |
3 |
6 |
8 |
Charging current(Max.) |
> 5A |
Charging voltage |
27.4VDC±1% |
82.1VDC±1% |
109.4VDC±1% |
PHYSICAL |
Standard model |
Dimension, LxWxH(mm) |
360x147x220 |
440x192x340 |
440x192x340 |
Net weight(kgs) |
11.9 |
22 |
27.9 |
Long-run model |
Dimension, LxWxH(mm) |
360x147x220 |
440x192x340 |
440x192x340 |
Net weight(kgs) |
8.5 |
16 |
18.2 |
ENVIRONMENT |
Humidity |
20-90%RH @0-40°C (non-condensing) |
Noise level |
Less than 55dBA@1 Meter |
MANAGEMENT |
Smart RS-232 |
Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC |
Optional SNMP |
Power management from SNMP Management and web browser |
|
Reviews