Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Valve sealed design, no free electrolyte, Maintenance -free
- Designed floating service life:15 years @ 25 °C/68 °F.
- Wide operating temperature range from -15°C to 35°C
- Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
- Low self-discharge rate: ≤3%/month.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | Features:
- Capacity: 2200W 2048Wh /640000mAh
- Input AC Output Power:Rated Power 2400W Peak Power 4800W
- Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
- Input Car Charging:DC12V~24V/10A 240W Max
- Input Solar Charging:DC16V~60V/10A 500W Max
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*QC18W+PD27W+PD100W Max
- DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support ; Battery Expandable: Support
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
| Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Specifications
MODEL |
LF33 10K |
LF33 20K |
LF33 30K |
LF33 40K |
LF33 60K |
LF33 80K |
LF33 100K |
LF33 120K |
LF33 160K |
LF33 200K |
CAPACITY |
10KVA /8KW |
20KVA /16KW |
30KVA /24KW |
40KVA /32KW |
60KVA /48KW |
80KVA /64KW |
100KVA /80KW |
120KVA /96KW |
160KVA /128KW |
200KVA /160KW |
INPUT |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Acceptable Voltage Range |
305VAC ~ 460VAC |
Frequency |
46-54Hzor56-64Hz |
INVERTER |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Precision |
Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) |
Frequency |
50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load) ; <5% (Non-linear Load) |
Phase Displacement |
120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load) |
Dynamic Recovery Time |
Restore to 90% of rated value in 3 cycles |
Overload capacity |
110% for 10min; 150% for 60sec; >160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ 100% Unbalanced Load |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
Type |
Solid state |
Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Frequency |
50/60 Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissible Overload |
150% for 1 hour; 180% for 30sec; >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
Type |
Without interruption |
Voltage |
3 * 400V (3Ph + N) |
Frequency |
50/60 Hz |
Overall Efficiency |
Line Mode |
90% |
91% |
92% |
93% |
Battery Mode |
90% |
91% |
93% |
93% |
BATTERY & CHARGER |
Battery Type and Numbers |
12VDC * 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Max.: 40 A |
Charging Voltage |
432 VDC (Based on 32pcs batteries) |
PHYSICAL |
Dimensions, D x W x H(mm) |
656 x 405 x 817 |
656 x 405 x 941 |
840x432x1140 |
975x554x1286 |
1200x910x1680 |
1500x1140x1800 |
Net Weight (Kgs) |
180 |
205 |
295 |
330 |
451 |
519 |
950 |
1350 |
| Features:
Digital Control
All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is morestableand reliable.Each module has built-in
automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance.
Intelligent Battery Management
Users can set the charging current, constant current, constant voltage and floatingcharging modescan be automatically and smoothly switched; Battery voltage can beset
±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional)
High Power Density Modular Design
The capacity of each single module is30kVA, and the height is3U; UPS modulescan be added and removed onlineto achieve zero maintenance time.
N+x Parallel Redundancy
The quantity of redundant module can be set accordingly, When the redundant module reaches more than 2 hours, the system availability achieves 99.99%,
MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets.
A maximum of four cabinets can be parallel,and battery pack can be shared when UPS cabinet in parallel.
Touchable LCD Display Screen
Super large LCD display with touching function.
Standard Cabinet Design
The appearance ofthe standard cabinet is beautiful and generous, which can perfectly match the use environment ofthe computer room and save the space.
Safe and Easy to Maintain
When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance;
Press EPO button to shutdown in emergentsituation, and also have REPO function.
Intelligent Management
Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMPcard (optional), can realize remote monitoringof UPS, relay card is optional.
Technical Specifications
Model |
VM 90K |
VM150K |
VM300K |
Capacity |
UPS Cabinet |
30-90KVA |
30-150KVA |
30-300KVA |
Power Module |
30kVA |
INPUT |
Input Form |
3P4W+G |
Rated Voltage |
380/400/415Vac |
Voltage Range |
207~478Vac |
Frequency Range |
40~70Hz |
Input Power Factor |
≥0.99 |
Bypass Range |
380 upper limit: 25% (optional +10%s +15%、+20%)
400 upper limit: 20% (optional +10%、+15%)
415 upper limit: 15% (optional +10%) Lower limit: -45% (optional -20%s -30%)
Bypass frequency protection range: ± 10% |
Input Current Harmonic Wave |
≤3% (100% non-linear) |
OUTPUT |
Output Form |
3P4W+G |
Rated Voltage |
380/400/415Vac |
Output Power Factor |
0.9 or 1 |
Voltage Accuracy |
±1% |
Output Frequency |
Mains Mode |
Synchronization with input; when mains frequency exceeds maximum value ±10%
(can be set ±1%、 ±2%、±4%、±5%), output frequency 50X(±0.2%)Hz |
Battery Mode |
(50/60±0.2%) Hz |
Crest Factor |
3:1 |
Conversion Time |
Mains mode — bypass mode: 0ms (tracking); Mains mode— battery mode: 0ms |
Overload Capacity |
Load≤110%: 60 mins;
Load≤125%: 10 mins;
Load≤150%: 1 min;
Load≥150%, shutdown immediately |
Output Voltage Harmonic Wave |
≤2% (100% linear) |
Efficiency |
In normal mode 95% |
Communication Port |
RS232、RS485、 Intelligent Slot*2 、 Dry connect port |
BATTERY |
Battery Voltage |
±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc; (32/34/36/38/40pcs Optional) |
Charging Current |
UPS Cabinet |
30A Max |
50A Max |
100A Max |
Power Module |
10A Max |
Environment |
Operating Temperature |
0〜40°C |
Relative Humidity |
0-95% (non-condensing) |
Storage Temperature |
-25-55°C (excluded battery) |
Altitude |
< 1500m (derating if exceeding 1500m) |
Physical Characteristic |
Outer Dimension (LxWxH) mm |
Cabinet |
840X600X1400 |
1100X600X2000 |
Module |
580 X 443 X 131 |
Weight
(Net Weight) KG |
Cabinet |
158 |
170 |
305 |
Module |
33.5 |
Operative Standard |
YD/T 2165-2010 |
| Features:
- True double-conversion
- LCD screen auto-rotation with Rack position ( only for 10K-20K models)
- DSP technology guarantees high performance
- Output power factor 1
- Support 1/1;3/1;3/3 Phase Adjustable
- Active power factor correction in all phases
- 50HZ / 60HZ frequency converter mode
- ECO mode operation for energy saving ( ECO)
- Emergency power off function ( EPO)
- Generator compatible
- Supports dual AC inputs
- 3-stage extendable charging design for optimized battery performance
- Adjustable battery numbers for long-run model
- Supporting Parallel sharing of battery packs
- Optional isolation transformer offers full isolation and complete common mode noise rejection
- Support with SNMP,USB, RS232 communication
Technical Specifications
MODEL |
33RM 10KL |
33RM 15KL |
33RM 20KL |
33RM 30KL |
33RM 40KL |
33RM 60KL |
CAPACITY |
10KVA/10KW |
15KVA/15KW |
20KVA/20KW |
30KVA/30KW |
40KVA/40KW |
60KVA/60KW |
PHASE |
3 Phase input / 3 Phase output |
PARALLEL CAPABILITY |
4 Max |
INPUT |
Nominal Voltage |
3×380 VAC (3Ph+N) |
Voltage Range |
190-520 VAC (3 Phase) @ 50% load , 305-478 VAC (3 Phase) @ 100% load |
Frequency Range |
46-54 Hz or 56~64Hz |
Power Factor |
≥ 0.99 @ 100% load |
OUTPUT |
Output Voltage |
3 x 360*/380/400/415 VAC (3Ph+N) |
AC Voltage Regulation (Batt. Mode) |
± 1% |
Frequency Range (Synchronized Range) |
46~54Hz or 56~64Hz |
Frequency Range (Batt. Mode) |
50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz |
Current Crest Ratio |
3:1 (max.) |
Harmonic Distortion |
≤1 % THD (Linear Load), ≤3% THD (Non-linear Load) |
Transfer Time |
AC mode to Battery mode |
zero |
Inverter to Bypass |
zero |
Waveform (Batt. Mode) |
Pure Sine Wave |
Overload |
AC Mode |
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection |
Battery Mode |
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection |
EFFICIENCY |
AC Mode |
95.5% |
ECO Mode |
98.5% |
Battery Mode |
94.5% |
BATTERY |
Battery Type |
Depending on the applications |
Numbers |
20 pcs |
32-40 pcs (Adjustable) |
Charging Current (max.) |
1A~ 12A (Adjustable) |
1A~ 16A (Adjustable) |
1A 〜18A (Adjustable) |
Charging Voltage |
±13.65 VDCx N (N=10) |
±13.65VxN (N=16〜20) |
PHYSICAL |
Dimension, D * W * H (mm) |
680*438*133 [3U] |
797*438*176 [4U] |
Net Weight (kgs) |
27 |
30 |
40 |
45 |
ENVIRONMENT |
Operation Temperture |
0-40°C |
Operation Humidity |
0-95% and non-condersing |
Noise Level |
Less than 62dB @ 1 Meter |
Less than 65dB @ 1 Meter |
Less than 70dB @ 1 Meter |
MANAGEMENT |
Smart RS-232/USB |
Supports Windows® Family, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browser |
| Features:
- Valve sealed design, no free electrolyte, Maintenance -free
- Designed floating service life:15 years @ 25 °C/68 °F.
- Wide operating temperature range from -15°C to 35°C
- Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
- Low self-discharge rate: ≤3%/month.
Application
- UPS Systems
- Portable Equipment
- Renewable Energy Systems
- Electric Utilities
- Outdoor control Equipment
- Railroad Utilities
- Telecom Systems
Technical Specifications
Model |
Nominal Voltage |
Capacity |
Dimension LXWXH (mm) |
Total Height
(mm) |
Weight (KG/IBS) |
Terminal |
VG12-33 |
12V |
33AH |
195 |
130 |
167 |
167 |
10 |
22.05 |
M6 |
VG12-35 |
12V |
35AH |
195 |
130 |
167 |
167 |
11.5 |
25.35 |
M6 |
VG12-38 |
12V |
38AH |
197 |
165 |
172 |
172 |
12.5 |
27.56 |
M6 |
VG12-40 |
12V |
40AH |
197 |
165 |
172 |
172 |
13.2 |
29.1 |
M6 |
VG12-45 |
12V |
45AH |
197 |
165 |
172 |
172 |
15 |
33.07 |
M6 |
VG12-50 |
12V |
50AH |
229 |
138 |
205 |
208 |
15.5 |
34.17 |
M6 |
VG12-55 |
12V |
55AH |
229 |
138 |
205 |
208 |
16.5 |
36.38 |
M6 |
VG12-65 |
12V |
65AH |
350 |
166 |
175 |
175 |
21 |
46.3 |
M8 |
VG12-70 |
12V |
70AH |
260 |
168 |
208 |
211 |
21.8 |
48.06 |
M8 |
VG12-80 |
12V |
80AH |
260 |
168 |
208 |
211 |
24 |
52.91 |
M8 |
VG12-90 |
12V |
90AH |
330 |
171 |
216 |
219 |
27 |
59.52 |
M8 |
VG12-100 |
12V |
100AH |
330 |
171 |
216 |
219 |
29.5 |
65.04 |
M8 |
VG12-120 |
12V |
120AH |
407 |
173 |
237 |
237 |
35 |
77.16 |
M8 |
VG12-150 |
12V |
150AH |
484 |
170 |
241 |
241 |
45 |
99.21 |
M8 |
VG12-200 |
12V |
200AH |
522 |
240 |
219 |
222 |
61.5 |
135.58 |
M8 |
VG12-250 |
12V |
250AH |
520 |
268 |
220 |
223 |
71 |
156.53 |
M8 |
| Features:
- Rated Power: 1000W
- Rated Capacity: 932.4wh
- Standard Capacity: 3.7V/252000mah
- Overload Protecion: 1050+40W
- AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
- Output Wave: Pure sine wave
- USB Output: QC 18W*2
- Type-c Output: PD 60W*2
- Cigarret Lighter Output: 14V/8A
- DC5525 Output: 14V/8A
- Wireless Charging: 15W
- Charging Input: 12-26 V/150W Max
- WorkingTemperature: -10-40 °C
- Weight(Net Weight): 8. 2kg
- Weight(With Accessories): 10.2kg
- Dimension: 345*227*203mm
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
|