Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
Valve sealed design, no free electrolyte, Maintenance -free
Designed floating service life:15 years @ 25 °C/68 °F.
Wide operating temperature range from -15°C to 35°C
Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
Low self-discharge rate: ≤3%/month.
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
Optional 7 ” touch LCD
Online double-conversionDSP technology guarantees high reliability
True galvanic isolation transformer designControl designed to withstand all kinds of loads
Intelligent battery management to prolong battery lifecycle
Redundant fan design and independent ventilation enhance durable operation under harsh environment
Adiustable battery numbers
Accept dual-mains input
Parallel operation with up to 4 units ( option )
Variety of communication options available
Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
Compact Size with nice housing case design. Stable performance with strong compatibility.
Built-in adapter, wide input, voltage range (100-240VAC).
Built-in multiple DC voltage (5/9/12/24/48VDC)output interfaces which can be used with external power adapters or solar panel.
Built-in large capacity lithium-ion batteries which is expanded up to 165Wh for long backup time.
100W has 19VDC output, it can be used for desktop computer / laptop computer.
60W/100W with WIFI function, it can be connected to the upper computer control. ( wall mounted type and tower type design).
Customize various of plugs and DC interfaces.
LCD indicator display design for monitor the working status easier.
Built-in multiple protection circuits, intelligently realize overcharge, over discharge, over current, overload, over temperature and short circuit protection
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
Capacity: 2200W 2048Wh /640000mAh
Input AC Output Power:Rated Power 2400W Peak Power 4800W
Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
Input Car Charging:DC12V~24V/10A 240W Max
Input Solar Charging:DC16V~60V/10A 500W Max
Output Voltage:230VAC±10%/110VAC±10%
Output Frequency: 50Hz±5%/60Hz±5%
USB Output:2*QC18W+PD27W+PD100W Max
DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
Output Waveform:Pure Sine Wave
LED:3 Levels(H/M/L)+SOS
UPS Function:Support ; Battery Expandable: Support
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLYIGBT Technology
Full microprocessor control with no-break static and manual bypasses.
Online double conversion technology (VFl) with isolation transformer on theinverter output.
Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output.
Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world.
SIMPLE TO INSTALL
Capability to install the UPS into any distribution system(neutral not required on rectifier input).
Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer
MAXIMUM BATTERY CARE
Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.
OTHER CHARACTERISTICS
0.8/0.9 power factor suitable for powering ICT and lndustrial loads.
BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur.
MAXIMUM RELIABILITY AND AVAILABILITY
Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings.
The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP)
LOW CONSUMPTION LEVELS
LF33 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.
ADVANCE COMMUNICATION:
RS485/RS232/Dry Contact/SNMP(Optional)
Specifications
Model
10KVA
20KVA
30KVA
40KVA
60KVA
80KVA
100KVA
120KVA
160KVA
200KVA
250KVA
300KVA
400KVA
500KVA
600KVA
Capacity
8KW
16 KW
24 KW
32 KW
48 KW
64 KW
80 KW
96 KW
128 KW
160 KW
200KW
240KW
320KW
400KW
480KW
INPUT
Rated voltage
400 VAC Three-Phase
Voltage range
380/400/415VAC(+25%,Can be set through the LCD panel)
Frequency range
40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ)
50±5%(±10%) Bypass synchronization tracking
Rectifying pulse number
6 pulse rectification
6/12 pulse rectification
12 pulse rectifier
Phase system
3φ4W+PE(Three phase five wire system)
Battery voltage
384VDC
480VDC
Battery Quantity
Standard with 32 Cells(30~34, can be set through the LCD panel) Standard 40 Cells(38~42 knots,can be set by LCD panel)
OUTPUT
Power factor
0.8/0.9 (Optional)
Voltage(V)
L-N: 220±1% L-L: 380±1%
Three-phase 100% load
unbalance voltage stability
≤2%,Allow 100% imbalance
Frequency(HZ)
Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms)
0ms
Parallel operation mode
(parallel type)
Max 8 Parallel
Waveform distortion
Linear loadTHD<3% ; Nonlinear loadTHD<5%
Overload capacity
125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply,
after reducing the loadcan automatically restore the inverter
Crest factor
3:1
Others
Index
Standard with no transfer time maintenance bypass switch
Communication function
RS232/RS485/Dry Contact/SNMP (Optional)
Panel display
LED displays working status and fault indication; LCD displays three-phase input voltage,
input frequency, three-phase output voltage, load,battery voltage, battery charge and discharge current, etc
Display
7″ Touchable LCD screen display
The audio noise(dB)
<65(within 1 meter)
Alarm function
Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection
Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Cooling way
Forced cooling
Operating temperature
0℃ to ~ 40℃
Humidity
0~95%, non-condensing
electromagnetic compatibility
Conform GB7260.2
Size(W*D*H)(mm)
540*660*1135
1100*800*1800
800*800*1900
1200*850*1900
2600*1100*2000
Weight
196
233
276
329
461
547.5
643
754
1375
Features:
Valve sealed design, no free electrolyte, Maintenance -free
Designed floating service life:15 years @ 25 °C/68 °F.
Wide operating temperature range from -15°C to 35°C
Nanometer gel electrolytes eliminate the acid stratification and prolong cycle life
Low self-discharge rate: ≤3%/month.
Application
UPS Systems
Portable Equipment
Renewable Energy Systems
Electric Utilities
Outdoor control Equipment
Railroad Utilities
Telecom Systems
Technical Specifications
Model
Nominal Voltage
Capacity
Dimension LXWXH (mm)
Total Height
(mm)
Weight (KG/IBS)
Terminal
VG12-33
12V
33AH
195
130
167
167
10
22.05
M6
VG12-35
12V
35AH
195
130
167
167
11.5
25.35
M6
VG12-38
12V
38AH
197
165
172
172
12.5
27.56
M6
VG12-40
12V
40AH
197
165
172
172
13.2
29.1
M6
VG12-45
12V
45AH
197
165
172
172
15
33.07
M6
VG12-50
12V
50AH
229
138
205
208
15.5
34.17
M6
VG12-55
12V
55AH
229
138
205
208
16.5
36.38
M6
VG12-65
12V
65AH
350
166
175
175
21
46.3
M8
VG12-70
12V
70AH
260
168
208
211
21.8
48.06
M8
VG12-80
12V
80AH
260
168
208
211
24
52.91
M8
VG12-90
12V
90AH
330
171
216
219
27
59.52
M8
VG12-100
12V
100AH
330
171
216
219
29.5
65.04
M8
VG12-120
12V
120AH
407
173
237
237
35
77.16
M8
VG12-150
12V
150AH
484
170
241
241
45
99.21
M8
VG12-200
12V
200AH
522
240
219
222
61.5
135.58
M8
VG12-250
12V
250AH
520
268
220
223
71
156.53
M8
Features:
Optional 7 ” touch LCD
Online double-conversionDSP technology guarantees high reliability
True galvanic isolation transformer designControl designed to withstand all kinds of loads
Intelligent battery management to prolong battery lifecycle
Redundant fan design and independent ventilation enhance durable operation under harsh environment
Adiustable battery numbers
Accept dual-mains input
Parallel operation with up to 4 units ( option )
Variety of communication options available
Reverse phase frequency operation and supportsnon-neutral input
50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed
±1 Hz/s
Waveform
Pure Sinewave
Total Harmonic Distortion (THDv)
<2% (Linear Load) ; <5% (Non-linear Load)
Phase Displacement
120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load)
Dynamic Recovery Time
Restore to 90% of rated value in 3 cycles
Overload capacity
110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor
3:1
Admissible Power Factor
0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load
<1%
Current Limit
High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type
Solid state
Voltage
3 x 380VAC/400VAC (3Ph + N)
Frequency
50/60 Hz
Activation Criterion
Microprocessor control
Transfer Time
Zero
Admissible Overload
150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass
Immediate, for overloads above 160%
Retransfer
Automatic after alarm clear
MAINTENANCE BYPASS
Type
Without interruption
Voltage
3 * 400V (3Ph + N)
Frequency
50/60 Hz
Overall Efficiency
Line Mode
90%
91%
92%
93%
Battery Mode
90%
91%
93%
93%
BATTERY & CHARGER
Battery Type and Numbers
12VDC * 32 pcs (29-32 pcs adjustable)
Nominal Battery Voltage
384 VDC (Based on 32pcs batteries)
Charging Method
CC/CV
Precision
±1%
Charging Current
Max.: 40 A
Charging Voltage
432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm)
656 x 405 x 817
656 x 405 x 941
840x432x1140
975x554x1286
1200x910x1680
1500x1140x1800
Net Weight (Kgs)
180
205
295
330
451
519
950
1350
Features:
Compact Size with nice housing case design. Stable performance with strong compatibility.
Built-in adapter, wide input, voltage range (100-240VAC).
Built-in multiple DC voltage (5/9/12/24/48VDC)output interfaces which can be used with external power adapters or solar panel.
Built-in large capacity lithium-ion batteries which is expanded up to 165Wh for long backup time.
100W has 19VDC output, it can be used for desktop computer / laptop computer.
60W/100W with WIFI function, it can be connected to the upper computer control. ( wall mounted type and tower type design).
Customize various of plugs and DC interfaces.
LCD indicator display design for monitor the working status easier.
Built-in multiple protection circuits, intelligently realize overcharge, over discharge, over current, overload, over temperature and short circuit protection
OPzV Tubular Gel Battery ( solid-state) 60AH-3000AH
Voltage class: 12V/2V
Capacity range: 60Ah~3000Ah
OPzV batteries offer high capacity reserve power and true deep cycling performance. With a design life of 20 years and a maintenance-free operation,
OPzV battery are perfect for regions with an unstable supply of electricity. OPzV battery are also completely spill-proof, which makes them safe to install anywhere,
even in remote environments with minimal supervision.
Reviews