Features:
  • Capacity: 2200W 2048Wh /640000mAh
  • Input AC Output Power:Rated Power 2400W Peak Power 4800W
  • Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC16V~60V/10A 500W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*QC18W+PD27W+PD100W Max
  • DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support ; Battery Expandable: Support

 

Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms

Reviews

There are no reviews yet.

Be the first to review “Portable Power Station PS Series 2200W”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsPortable Power Station PS Series 2200W remove3 Phase Low Frequency Solar Inverter DX Series remove3 Phase Low Frequency Online UPS LD33 Series remove3 Phase High Frequency Online UPS removeHigh Frequency Rack Mount UPS 33RM Series removeDC UPS with POE Port 18W 36W with 10400mah Lithium Battery remove
NamePortable Power Station PS Series 2200W remove3 Phase Low Frequency Solar Inverter DX Series remove3 Phase Low Frequency Online UPS LD33 Series remove3 Phase High Frequency Online UPS removeHigh Frequency Rack Mount UPS 33RM Series removeDC UPS with POE Port 18W 36W with 10400mah Lithium Battery remove
Image
SKUSF1033560130139-22SF1033560130139-5SF1033560130139-3SF1033560130139-1SF1033560130139-12SF1033560130139-6
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Features:
  • DSP digital control technology enables UPS more stable performance-+
  • Environment friendly eco-designed
  • Active input power factor correction
  • Wide range of input voltage and frequency
  • Zero power switch delay
  • Adaptive Load Management.
  • Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
  • Support the generator
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
  • Wide AC input voltage range 85~265Vac.
  • Inbuilt 4* 2600mah lithium battery to support longer power supply for loads.
  • DC output interfaces support USB (5V) /9V/12V/ 15V/24V (POE)
  • Ethernet power supply: one network cable can transmit data and electric power at the same time.
  • Over-charging, Over-discharging and Short Circuit protection
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
  • Capacity: 2200W 2048Wh /640000mAh
  • Input AC Output Power:Rated Power 2400W Peak Power 4800W
  • Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
  • Input Car Charging:DC12V~24V/10A 240W Max
  • Input Solar Charging:DC16V~60V/10A 500W Max
  • Output Voltage:230VAC±10%/110VAC±10%
  • Output Frequency: 50Hz±5%/60Hz±5%
  • USB Output:2*QC18W+PD27W+PD100W Max
  • DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
  • Output Waveform:Pure Sine Wave
  • LED:3 Levels(H/M/L)+SOS
  • UPS Function:Support ; Battery Expandable: Support
 
Applications:
  • Mammogram
  • Ultrasound Equipments
  • Radiology rooms
Features:
Three Phase Hybrid Solar Inverter Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding  100kva/120kva/125kva/150kva/160kva,384vdc to 380vac. •Pure sine wave output. •Low DC voltage, saving system cost. •Three phase solar inverter with built-in PWM or MPPT charge controller. •AC charge current 0-45A adjustable. •Wide LCD screen, clearly and precisely shows icon data. •100%imbalance loading design, 3 times peak power. •Setting different working modes based on variable usage requirements. •DC first/AC first optional. •Various communication ports and remote controls  
Specifications
MODEL DX100KVA DX120KVA DX125KVA DX150KVA DX160KVA 190KVA 200KVA
Rated Power 80KW 96KW 100KW 120KW 128KW 150KW 160KW
Peak Power(20ms) 240KVA 288KVA 300KVA 360KVA 384KVA 450KVA 480KVA
Start Motor 40HP 50HP 50HP 60HP 60HP 80HP 80HP
Battery Voltage 384VDC
Size(L*W*Hmm) 875*720*1380 1123*900*1605
Packing Size(L*W*Hmm) 980*825*1560 1185*960*1750
N.W.(kg) 512 592 612 612 642 705 755
G.W.(kg)(Wooden Packing) 552 632 652 652 692 755 805
INPUT DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
AC Input Frequency Range 45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz)
Max AC charging current 0-45A(Depending on the model)
AC charging method Three-stage (constant current, constant voltage, floating charge)
Phase 3 PHASE
OUTPUT Efficiency(Battery Mode) ≥85%
Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
Output Frequency(Battery Mode) 50/60Hz ±1%
Output Wave(Battery Mode) Pure Sine Wave
Output waveform distortion Linear load≤3%
Efficiency(AC Mode) >99%
Output Voltage(AC Mode) Conforming to AC input
Output Frequency(AC Mode) Conforming to AC input
No load loss(Battery Mode) ≤1% rated power
No load loss(AC Mode) ≤2%rated power( charger does not work in AC mode)
No load loss (Energy saving Mode) ≤10W
Phase 3 PHASE
BATTERY VRLA Battery Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage)
Customize battery Charging and discharging parameters of different types of batteries can be customized according to user requirements
(charging and discharging parameters of different types of batteries can be set through the operation panel)
Protection Battery undervoltage alarm 11V(Single battery voltage)
Battery undervoltage protection 10.5V(Single battery voltage)
Battery overvoltage alarm 15V(Single battery voltage)
Battery overvoltage protection 17V(Single battery voltage)
Battery overvoltage recovery voltage 14.5V(Single battery voltage)
Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Inverter output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
Temperature protection >90°C(Shut down output)
Alarm A Normal working condition, buzzer has no alarm sound
B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
Inside Solar controller Charging Mode MPPT or PWM
(Optional) Charging current PWM: 100A-200A / MPPT: 50A/100A
PV Input Voltage Range PWM: 480V-704V / MPPT: 480V-640V
Max PV Input Voltage(Voc) PWM: 750V / MPPT: 800V
(At the lowest temperature)
PV Array Maximum Power PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A)
Standby loss ≤3W
Maximum conversion efficiency >95%
Working Mode Battery First/AC First/Saving Energy Mode
Transfer Time ≤4ms
Display LCD
Thermal method Forced Air Cooling
Communication(Optional) RS485/APP(WIFI monitoring or GPRS monitoring)
Environment Operating temperature -10℃~40℃
Storage temperature -15℃~60℃
Noise 2000m(More than derating)
Elevation ≤65dB
Humidity 0%~95% ,No condensation
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLY IGBT Technology Full microprocessor control with no-break static and manual bypasses. Online double conversion technology (VFl) with isolation transformer on theinverter output. Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output. Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world. SIMPLE TO INSTALL Capability to install the UPS into any distribution system(neutral not required on rectifier input). Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer MAXIMUM BATTERY CARE Battery deep discharge protection; Temperature compensating charger; Built-in automatic and manual battery test feature. OTHER CHARACTERISTICS 0.8/0.9 power factor suitable for powering ICT and lndustrial loads. BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur. MAXIMUM RELIABILITY AND AVAILABILITY Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP) LOW CONSUMPTION LEVELS LF33 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail. ADVANCE COMMUNICATION: RS485/RS232/Dry Contact/SNMP(Optional)  
Specifications
Model 10KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 160KVA 200KVA 250KVA 300KVA 400KVA 500KVA 600KVA
Capacity 8KW 16 KW 24 KW 32 KW  48 KW 64 KW  80 KW 96 KW 128 KW 160 KW 200KW 240KW 320KW 400KW  480KW
INPUT
Rated voltage 400 VAC  Three-Phase
Voltage range 380/400/415VAC(+25%,Can be set through the LCD panel)
Frequency range 40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ) 50±5%(±10%) Bypass synchronization tracking
Rectifying pulse number 6 pulse rectification 6/12 pulse rectification 12 pulse rectifier
Phase system 3φ4W+PE(Three phase five wire system)
Battery voltage 384VDC 480VDC
Battery Quantity Standard with 32 Cells(30~34, can be set through the LCD panel)  Standard 40 Cells(38~42 knots,can be set by LCD panel)
OUTPUT
Power factor 0.8/0.9 (Optional)
Voltage(V) L-N: 220±1%   L-L: 380±1%
Three-phase 100% load unbalance voltage stability ≤2%,Allow 100% imbalance
Frequency(HZ) Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms) 0ms
Parallel operation mode (parallel type) Max 8 Parallel
Waveform distortion Linear loadTHD<3% ; Nonlinear loadTHD<5%
Overload capacity 125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply, after reducing the loadcan automatically restore the inverter
Crest factor 3:1
Others
Index Standard with no transfer time maintenance bypass switch
Communication function RS232/RS485/Dry Contact/SNMP (Optional)
Panel display LED displays working status and fault indication; LCD displays three-phase input voltage, input frequency, three-phase output voltage, load,battery voltage, battery charge and discharge current, etc
Display  7″ Touchable LCD screen display
The audio noise(dB) <65(within 1 meter)
Alarm function Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Cooling way Forced cooling
Operating temperature 0℃ to  ~ 40℃
Humidity 0~95%, non-condensing
electromagnetic compatibility Conform GB7260.2
Size(W*D*H)(mm) 540*660*1135 1100*800*1800 800*800*1900 1200*850*1900 2600*1100*2000
Weight 196     233 276 329 461 547.5 643 754 1375
Features:
  • DSP digital control technology enables UPS more stable performance-+
  • Environment friendly eco-designed
  • Active input power factor correction
  • Wide range of input voltage and frequency
  • Zero power switch delay
  • Adaptive Load Management.
  • Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
  • Support the generator
 
Specifications:
Model 33VT 10K 33VT 10KL 33VT 20K 33VT 20KL 33VT 30KL 33VT 40KL
Capacity 10KVA/9000W 20KVA/18KW 30KVA/27KW 40KVA/36KW
Input Nominal Voltage 380/400/415Vac
Voltage Range 207-475VAC(3P4W+G)
Current 14A 28A 42A 67A
Frequency 40-70Hz (Adjustable)
Power Factor ≥0.99
Output Voltage 380VAC 1±1% (3P4W+G)
Frequency 46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz -54-60Hz);50Hz(Battery mode)
Current 15A 30A 45A 61A
Power Factor 0.9
Crest Factor 3:1
THD Line load <3%
Chrage Current 5.5A 1A 7.5A 1A 5.5A
Battery Nominal Voltage 192VDC ±192VDC
Transfer Time 0ms
Overload Capacity 105%±5%< Load<125%±5% :1 min transfer to bypass 125% ±5% < Load<135 % ±5 % :30s transfer to bypass Load > 135 % ± 5 %: 300s transfer to bypass
Communication SNMP,RS-232,USB+lntelligent Slot
Operating Environment Temperature 0°C~40°C
Humidity 20%~95%
Dimension Width (mm) 260 260 260 260
Depth (mm) 560 533 710 560
Height (mm) 717 501 717 717
Net Weight(Kg) 26 72 57.5 98 58.5 62
Features:
  • True double-conversion
  • LCD screen auto-rotation with Rack position ( only for 10K-20K models)
  • DSP technology guarantees high performance
  • Output power factor 1
  • Support 1/1;3/1;3/3 Phase Adjustable
  • Active power factor correction in all phases
  • 50HZ / 60HZ frequency converter mode
  • ECO mode operation for energy saving ( ECO)
  • Emergency power off function ( EPO)
  • Generator compatible
  • Supports dual AC inputs
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery numbers for long-run model
  • Supporting Parallel sharing of battery packs
  • Optional isolation transformer offers full isolation and complete common mode noise rejection
  • Support with SNMP,USB, RS232 communication
 
Technical Specifications
MODEL 33RM 10KL 33RM 15KL 33RM 20KL 33RM 30KL 33RM 40KL 33RM 60KL
CAPACITY 10KVA/10KW 15KVA/15KW 20KVA/20KW 30KVA/30KW 40KVA/40KW 60KVA/60KW
PHASE 3 Phase input / 3 Phase output
PARALLEL CAPABILITY 4 Max
INPUT
Nominal Voltage 3×380 VAC (3Ph+N)
Voltage Range 190-520 VAC (3 Phase) @ 50% load , 305-478 VAC (3 Phase) @ 100% load
Frequency Range 46-54 Hz or 56~64Hz
Power Factor ≥ 0.99 @ 100% load
OUTPUT
Output Voltage 3 x 360*/380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤1 % THD (Linear Load), ≤3% THD (Non-linear Load)
Transfer Time AC mode to Battery mode zero
Inverter to Bypass zero
Waveform (Batt. Mode) Pure Sine Wave
Overload AC Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
Battery Mode 100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
EFFICIENCY
AC Mode 95.5%
ECO Mode 98.5%
Battery Mode 94.5%
BATTERY
Battery Type Depending on the applications
Numbers 20 pcs 32-40 pcs (Adjustable)
Charging Current (max.) 1A~ 12A (Adjustable) 1A~ 16A (Adjustable) 1A 〜18A (Adjustable)
Charging Voltage ±13.65 VDCx N (N=10) ±13.65VxN (N=16〜20)
PHYSICAL
Dimension, D * W * H (mm) 680*438*133 [3U] 797*438*176 [4U]
Net Weight (kgs) 27 30 40 45
ENVIRONMENT
Operation Temperture 0-40°C
Operation Humidity 0-95% and non-condersing
Noise Level Less than 62dB @ 1 Meter Less than 65dB @ 1 Meter Less than 70dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows® Family, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Features:
  • Wide AC input voltage range 85~265Vac.
  • Inbuilt 4* 2600mah lithium battery to support longer power supply for loads.
  • DC output interfaces support USB (5V) /9V/12V/ 15V/24V (POE)
  • Ethernet power supply: one network cable can transmit data and electric power at the same time.
  • Over-charging, Over-discharging and Short Circuit protection
 
Specifications
Model DC 1018P DC 1036P
INPUT
Input Voltage 85 – 265Vac
Output
DC Output Voltage 5V             2A 5V             2A
USB            2A USB            2A
9V             1A 9V             1A
12V             1A 12V             1A
15V/24V(POE)       0.5A 15V/24V(POE)       0.5A
18W 36W
BATTERY
Battery Type Lithium Battery
Capacity of Battery 2600mAh * 4
PROTECTION
Protect Over-charging, Over-discharging and Short Circuit
ENVIRNMENT
Operation Temperature 0°C – 40°C
Noise Level Less than 40dB
Dimension(mm) 160 * 105 * 33
Net Weight(kg) 0.40 0.42
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare