Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
60KW single power module in 3U
N+1or N+X parallel redundancy for power guarantee
Supports horizontal expansion by 1+1 cabinet paralleloperation.
Hot-swappable modular design decreases MTTR
High scalability
Built-in maintenance bypass switch for easy maintenance without interruptible
High efficiency double conversion online UPS
Flexible battery configuration and adjustable charging current
High overload capability
Power walk-in function
Built-in dynamic password protection
Built-in ultra communication slot
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
Intelligent CPU control
Automatic power on when the the main power recovers
Cold start function
Power off charging function
USB/RS232/RJ-11/RJ-45 communication port (optional)
Offering LED and LCD panels for selection
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three-level inverter technology
Active High input power factor correction technology (PFC)
Wide Input Voltage Frequency Range& Strong load capacity
Zero power switch delay
Compatible with Generators
Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
Support intelligent monitoring
Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
Capacity: 2200W 2048Wh /640000mAh
Input AC Output Power:Rated Power 2400W Peak Power 4800W
Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
Input Car Charging:DC12V~24V/10A 240W Max
Input Solar Charging:DC16V~60V/10A 500W Max
Output Voltage:230VAC±10%/110VAC±10%
Output Frequency: 50Hz±5%/60Hz±5%
USB Output:2*QC18W+PD27W+PD100W Max
DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
Output Waveform:Pure Sine Wave
LED:3 Levels(H/M/L)+SOS
UPS Function:Support ; Battery Expandable: Support
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Features:
60KW single power module in 3U
N+1or N+X parallel redundancy for power guarantee
Supports horizontal expansion by 1+1 cabinet paralleloperation.
Hot-swappable modular design decreases MTTR
High scalability
Built-in maintenance bypass switch for easy maintenance without interruptible
High efficiency double conversion online UPS
Flexible battery configuration and adjustable charging current
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
Battery Mode
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
EFFICIENCY
AC Mode
95.5%
ECO Mode
98.5%
Battery Mode
94.5%
BATTERY
Battery Type
Depending on the applications
Numbers
20 pcs
32-40 pcs (Adjustable)
Charging Current (max.)
1A~ 12A (Adjustable)
1A~ 16A (Adjustable)
1A 〜18A (Adjustable)
Charging Voltage
±13.65 VDCx N (N=10)
±13.65VxN (N=16〜20)
PHYSICAL
Dimension, D * W * H (mm)
680*438*133 [3U]
797*438*176 [4U]
Net Weight (kgs)
27
30
40
45
ENVIRONMENT
Operation Temperture
0-40°C
Operation Humidity
0-95% and non-condersing
Noise Level
Less than 62dB @ 1 Meter
Less than 65dB @ 1 Meter
Less than 70dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB
Supports Windows® Family, Linux and MAC
Optional SNMP
Power management from SNMP manager and web browser
Features:
Intelligent CPU control
Automatic power on when the the main power recovers
Cold start function
Power off charging function
USB/RS232/RJ-11/RJ-45 communication port (optional)
Offering LED and LCD panels for selection
Application:
Personal Computer
Printer
POS(Point of sales)Terminals
Security System
Fax Machine
Modem, WiFi Router
Technical Specifications:
Model
DP600
DP1000
DP1200
DP2000
DP3000
Capacity
600VA/360W
1000VA/600W
1200VA/720W
2000VA/1200W
3000VA/1800W
INPUT
Voltage
110/120VAA or 220/230/240VAC
Voltage Range
67-137VAC/135-275VAC
Frequency Range
50Hz Or 60Hz(Auto-Sensing)
OUTPUT
Output Voltage
110/120VAA or 220/230/240VAC
AC Voltage Regulation
± 10%
Frequency Range
(Batt. Mode)
50 HZ or 60 Hz ± 10%
Transfer Time
Typical 6-10 ms
Waveform
(Battery Mode)
Simulated Sine Wave
BATTERY
Battery Voltage
12V/7AH*1
12V/9AH*1
12V/7AH*2
12V/9AH*2
12V/7AH*4
Charge Time
8 hours up to 80-90%
PROTECTION
Full Protection
Auto Detection, discharge protection,output Short circuit, Over load, Battery low voltage protection
Communication Port
USB/RS232/RJ11/RJ45 (Optional)
Display
LED/LCD
Alarm
Battery Mode
Every 4 Seconds one beep
Low Battery Capacity
Every 1 Seconds one beep
Overload
Every 1 Seconds one beep
Fault
Keep beeping
ENVIRONMENT
Humidity
0-90% Rh @ 0-40℃ (Non-Condensing)
Noise Level
40dB
Dimension(mm)
320*90*140
330* 100*150
365*140*165
365*140*165
395*145*210
N.W.(kg)
5.2
6
10
12.6
21
Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three-level inverter technology
Active High input power factor correction technology (PFC)
Wide Input Voltage Frequency Range& Strong load capacity
Zero power switch delay
Compatible with Generators
Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
Support intelligent monitoring
Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Technical Specifications
Model
VT1K
VT1KL
VT2K
VT2KL
VT3K
VT3KL
Rated power
1KVA/900KW
2KVA/1.8KW
3KVA/2.7KW
Input
Voltage range
90~285Vac L+N+G
Frequency range
40-70Hz(Adjustable)
Input power factor
>0.99
Output
Rated voltage and precision
220Vac (1±2% ) L+N+G
Output frequency
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Rated Current
4.5A
9.1A
13.6A
Output power factor
0.9
Output harmonic
≤4%
Crest factor
3:1
Inverter overload capacity
105%±5%< Load<125%±5% : 50s transfer to bypass
125% ±5% < Load<150 % ±5 % : 25s transfer to bypass
Load > 150 % ± 5 %: 300s transfer to bypass
Transfer time
0ms
Efficiency
≥85%
Battery
Rated voltage
24Vdc
36Vdc
48Vdc
72Vdc
72Vdc
96Vdc
Battery Numbers
2
3
4
6
6
8
Charge current
1A
6.5A
1A
5.5A
1A
5.5A
Size(LXWXH)mm
350*144*230
425*190*328
Net Weight(KG)
9.5kg
6kg
18.5kg
10kg
23.5kg
11kg
Operating temperature
0°C 〜40°C
Operating humidity
20% 〜95%
Noise
≤50dB
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLYIGBT Technology
Full microprocessor control with no-break static and manual bypasses.
Online double conversion technology (VFl) with isolation transformer on theinverter output.
Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output.
Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world.
SIMPLE TO INSTALL
Capability to install the UPS into any distribution system(neutral not required on rectifier input).
Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer
MAXIMUM BATTERY CARE
Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.
OTHER CHARACTERISTICS
0.8/0.9 power factor suitable for powering ICT and lndustrial loads.
BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur.
MAXIMUM RELIABILITY AND AVAILABILITY
Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings.
The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP)
LOW CONSUMPTION LEVELS
LF31 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.
ADVANCE COMMUNICATION:
RS485/RS232/Dry Contact/SNMP(Optional)
Specifications
Model
10KVA
15KVA
20KVA
30KVA
40KVA
60KVA
80KVA
100KVA
Capacity
8KW
12 KW
16 KW
24 KW
32 KW
48 KW
64 KW
80 KW
INPUT
Rated voltage
380/400/415 VAC Three-phase
Voltage range
±20%
Frequency range
45-65Hz
Power factor
>0.92 with harmonic filter
Current harmonic distortion
<5% with harmonic filter
Soft Start
0 -100% in 10″
BYPASS INPUT
Rated voltage
230VAC Single Phase
Permitted voltage range
±15% (selectable from ±10% to ±25% from front panel)
Reviews