Content | Features:
- Capacity: 2200W 2048Wh /640000mAh
- Input AC Output Power:Rated Power 2400W Peak Power 4800W
- Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
- Input Car Charging:DC12V~24V/10A 240W Max
- Input Solar Charging:DC16V~60V/10A 500W Max
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*QC18W+PD27W+PD100W Max
- DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support ; Battery Expandable: Support
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
| Features:
- True Double conversion Technology
- DSP digital control technology enable UPS more stable performance.
- Three Level inverter control technology
- Large screen LCD display
- N+X Parallel Redundancy function (3 units parallel)
- EPO emergency stop function
- Smart expansion Slots (optional)
- Support Generator
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
Technical Specifications
Model |
VT6K |
VT6KL |
VT10K |
VT10KL |
31VT10KL |
31VT15KL |
31VT20KL |
Capacity |
6KVA/5400W |
10KVA/9000W |
15KVA/13.5KW |
20KVA/18KW |
Input |
Nominal Voltage |
220/230/240Vac |
380/400/415Vac |
Voltage Range |
120-275VAC(1P2W+G) |
207-475VAC(3P4W+G) |
Current |
31A (max) |
50A(max) |
50A (max) |
75A(max) |
100A(max) |
Frequency |
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode) |
Power Factor |
≥0.99· |
Output |
Voltage |
220/230/240±2%Vac (1P2W+G) |
Frequency |
50/60 Hz(adjustable)
50/60Hz± 5% (Line mode)
50/60Hz ± 0.05Hz ( Battery mode) |
Current |
27.3A |
45A |
68A |
91A |
Power Factor |
0.9 |
Waveform |
Pure Sine Wave |
Waveform Distortion |
Line load <2% |
Line load <3% |
Back-up Time |
Full Load |
≥7′ |
Depends on external batteries bank’s Capacity |
≥5′ |
Depends on external batteries bank’s Capacity |
Half Load |
≥20 |
≥13′ |
Battery Nominal Voltage |
192/240Vdc |
Transfer Time |
0ms |
Overload Capacity |
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass |
Communication |
SNMP,RS-232,USB+lntelligent Slot |
Operating Environment |
Temperature |
0°C~40°C |
Humidity |
15%~90% |
Dimension |
Width (mm) |
260 |
260 |
260 |
260 |
260 |
Depth (mm) |
560 |
533 |
560 |
533 |
560 |
Height (mm) |
717 |
501 |
717 |
501 |
717 |
Net Weight(Kg) |
55 |
12.2 |
62 |
21 |
23 |
32 |
33 |
| Features:
Digital Control
All parts of this series of UPS adopt digital control, each performance index of UPS is very excellent, and the control system is morestableand reliable.Each module has built-in
automatic bypass switch and corresponding bypass current equalizing inductor, providing good bypass power supply equalization performance.
Intelligent Battery Management
Users can set the charging current, constant current, constant voltage and floatingcharging modescan be automatically and smoothly switched; Battery voltage can beset
±192Vdc/±240Vdc/±216Vdc/±228Vdc/±240Vdc (32/34/36/38/40 pcs optional)
High Power Density Modular Design
The capacity of each single module is30kVA, and the height is3U; UPS modulescan be added and removed onlineto achieve zero maintenance time.
N+x Parallel Redundancy
The quantity of redundant module can be set accordingly, When the redundant module reaches more than 2 hours, the system availability achieves 99.99%,
MTBF(Mean Time Between Failures) lasts more than 250,000 hours; Supporting parallel connection between cabinets.
A maximum of four cabinets can be parallel,and battery pack can be shared when UPS cabinet in parallel.
Touchable LCD Display Screen
Super large LCD display with touching function.
Standard Cabinet Design
The appearance ofthe standard cabinet is beautiful and generous, which can perfectly match the use environment ofthe computer room and save the space.
Safe and Easy to Maintain
When an emergency occurs, users can switch to the maintenance bypass to supply power, and maintenance personnel can safely perform online maintenance;
Press EPO button to shutdown in emergentsituation, and also have REPO function.
Intelligent Management
Centralized monitoring module (with hot-swap function), RS232/RS485 communication interface/SNMPcard (optional), can realize remote monitoringof UPS, relay card is optional.
Technical Specifications
Model |
VM 90K |
VM150K |
VM300K |
Capacity |
UPS Cabinet |
30-90KVA |
30-150KVA |
30-300KVA |
Power Module |
30kVA |
INPUT |
Input Form |
3P4W+G |
Rated Voltage |
380/400/415Vac |
Voltage Range |
207~478Vac |
Frequency Range |
40~70Hz |
Input Power Factor |
≥0.99 |
Bypass Range |
380 upper limit: 25% (optional +10%s +15%、+20%)
400 upper limit: 20% (optional +10%、+15%)
415 upper limit: 15% (optional +10%) Lower limit: -45% (optional -20%s -30%)
Bypass frequency protection range: ± 10% |
Input Current Harmonic Wave |
≤3% (100% non-linear) |
OUTPUT |
Output Form |
3P4W+G |
Rated Voltage |
380/400/415Vac |
Output Power Factor |
0.9 or 1 |
Voltage Accuracy |
±1% |
Output Frequency |
Mains Mode |
Synchronization with input; when mains frequency exceeds maximum value ±10%
(can be set ±1%、 ±2%、±4%、±5%), output frequency 50X(±0.2%)Hz |
Battery Mode |
(50/60±0.2%) Hz |
Crest Factor |
3:1 |
Conversion Time |
Mains mode — bypass mode: 0ms (tracking); Mains mode— battery mode: 0ms |
Overload Capacity |
Load≤110%: 60 mins;
Load≤125%: 10 mins;
Load≤150%: 1 min;
Load≥150%, shutdown immediately |
Output Voltage Harmonic Wave |
≤2% (100% linear) |
Efficiency |
In normal mode 95% |
Communication Port |
RS232、RS485、 Intelligent Slot*2 、 Dry connect port |
BATTERY |
Battery Voltage |
±192Vdc/±204Vdc/±216Vdc/±228Vdc/±240Vdc; (32/34/36/38/40pcs Optional) |
Charging Current |
UPS Cabinet |
30A Max |
50A Max |
100A Max |
Power Module |
10A Max |
Environment |
Operating Temperature |
0〜40°C |
Relative Humidity |
0-95% (non-condensing) |
Storage Temperature |
-25-55°C (excluded battery) |
Altitude |
< 1500m (derating if exceeding 1500m) |
Physical Characteristic |
Outer Dimension (LxWxH) mm |
Cabinet |
840X600X1400 |
1100X600X2000 |
Module |
580 X 443 X 131 |
Weight
(Net Weight) KG |
Cabinet |
158 |
170 |
305 |
Module |
33.5 |
Operative Standard |
YD/T 2165-2010 |
| Features:
- Pure sine wave output
- DSP digital control
- Boost and buck AVR for voltage stabilization
- Cold start function
- Intelligent battery management
- Short circuit and overload protection
- Off-mode charging
- Offering LED and LCD panels for selection
- Optional USB/RS232/RJ45/SNMP communication port
Technical Specifications
MODEL |
UPS-AP1K ( L ) |
UPS-AP2K ( L ) |
UPS-AP3K ( L ) |
Capacity |
1000VA/700W |
2000VA/1400W |
3000VA/2100W |
INPUT |
Voltage range |
145~275VAC±5V |
Frequency range |
50Hz-60Hz |
OUTPUT |
Output voltage |
220VAC |
AC voltage range |
±10% |
Frequency range(batt.mode) |
50Hz ± 0.25Hz or 60Hz ± 0.3Hz |
Overload |
105%-110%: UPS beep alarm, do not shut down. |
110%-130%: auto shut down after 30 seconds |
> 130%: auto shut down immediately |
Transfer time |
<typical 4ms |
Waveform(batt.mode) |
Pure sine wave |
BATTERY |
Standard model |
Battery type |
12V7Ah |
Numbers |
2 |
4 |
6 |
Charging current(Max.) |
Assume: 1A± 10%; Max: 1A or 2A for option |
Charging voltage |
27.3VDC±1% |
54.7VDC±1% |
82.0VDC±1% |
Long-run model |
Battery type |
12V, AH depending on applicant |
Numbers |
3 |
6 |
8 |
Charging current(Max.) |
> 5A |
Charging voltage |
27.4VDC±1% |
82.1VDC±1% |
109.4VDC±1% |
PHYSICAL |
Standard model |
Dimension, LxWxH(mm) |
360x147x220 |
440x192x340 |
440x192x340 |
Net weight(kgs) |
11.9 |
22 |
27.9 |
Long-run model |
Dimension, LxWxH(mm) |
360x147x220 |
440x192x340 |
440x192x340 |
Net weight(kgs) |
8.5 |
16 |
18.2 |
ENVIRONMENT |
Humidity |
20-90%RH @0-40°C (non-condensing) |
Noise level |
Less than 55dBA@1 Meter |
MANAGEMENT |
Smart RS-232 |
Support windows 2000/2003/XP/Vista/2008, Windows7/8, Linux, Unix, and MAC |
Optional SNMP |
Power management from SNMP Management and web browser |
| Features:
- True double-conversion
- LCD screen auto-rotation with Rack position ( only for 10K-20K models)
- DSP technology guarantees high performance
- Output power factor 1
- Support 1/1;3/1;3/3 Phase Adjustable
- Active power factor correction in all phases
- 50HZ / 60HZ frequency converter mode
- ECO mode operation for energy saving ( ECO)
- Emergency power off function ( EPO)
- Generator compatible
- Supports dual AC inputs
- 3-stage extendable charging design for optimized battery performance
- Adjustable battery numbers for long-run model
- Supporting Parallel sharing of battery packs
- Optional isolation transformer offers full isolation and complete common mode noise rejection
- Support with SNMP,USB, RS232 communication
Technical Specifications
MODEL |
33RM 10KL |
33RM 15KL |
33RM 20KL |
33RM 30KL |
33RM 40KL |
33RM 60KL |
CAPACITY |
10KVA/10KW |
15KVA/15KW |
20KVA/20KW |
30KVA/30KW |
40KVA/40KW |
60KVA/60KW |
PHASE |
3 Phase input / 3 Phase output |
PARALLEL CAPABILITY |
4 Max |
INPUT |
Nominal Voltage |
3×380 VAC (3Ph+N) |
Voltage Range |
190-520 VAC (3 Phase) @ 50% load , 305-478 VAC (3 Phase) @ 100% load |
Frequency Range |
46-54 Hz or 56~64Hz |
Power Factor |
≥ 0.99 @ 100% load |
OUTPUT |
Output Voltage |
3 x 360*/380/400/415 VAC (3Ph+N) |
AC Voltage Regulation (Batt. Mode) |
± 1% |
Frequency Range (Synchronized Range) |
46~54Hz or 56~64Hz |
Frequency Range (Batt. Mode) |
50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz |
Current Crest Ratio |
3:1 (max.) |
Harmonic Distortion |
≤1 % THD (Linear Load), ≤3% THD (Non-linear Load) |
Transfer Time |
AC mode to Battery mode |
zero |
Inverter to Bypass |
zero |
Waveform (Batt. Mode) |
Pure Sine Wave |
Overload |
AC Mode |
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection |
Battery Mode |
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection |
EFFICIENCY |
AC Mode |
95.5% |
ECO Mode |
98.5% |
Battery Mode |
94.5% |
BATTERY |
Battery Type |
Depending on the applications |
Numbers |
20 pcs |
32-40 pcs (Adjustable) |
Charging Current (max.) |
1A~ 12A (Adjustable) |
1A~ 16A (Adjustable) |
1A 〜18A (Adjustable) |
Charging Voltage |
±13.65 VDCx N (N=10) |
±13.65VxN (N=16〜20) |
PHYSICAL |
Dimension, D * W * H (mm) |
680*438*133 [3U] |
797*438*176 [4U] |
Net Weight (kgs) |
27 |
30 |
40 |
45 |
ENVIRONMENT |
Operation Temperture |
0-40°C |
Operation Humidity |
0-95% and non-condersing |
Noise Level |
Less than 62dB @ 1 Meter |
Less than 65dB @ 1 Meter |
Less than 70dB @ 1 Meter |
MANAGEMENT |
Smart RS-232/USB |
Supports Windows® Family, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browser |
| Features:
Three Phase Hybrid Solar Inverter
Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding 100kva/120kva/125kva/150kva/160kva,384vdc to 380vac.
•Pure sine wave output.
•Low DC voltage, saving system cost.
•Three phase solar inverter with built-in PWM or MPPT charge controller.
•AC charge current 0-45A adjustable.
•Wide LCD screen, clearly and precisely shows icon data.
•100%imbalance loading design, 3 times peak power.
•Setting different working modes based on variable usage requirements.
•DC first/AC first optional.
•Various communication ports and remote controls
Specifications
MODEL |
DX100KVA |
DX120KVA |
DX125KVA |
DX150KVA |
DX160KVA |
190KVA |
200KVA |
Rated Power |
80KW |
96KW |
100KW |
120KW |
128KW |
150KW |
160KW |
Peak Power(20ms) |
240KVA |
288KVA |
300KVA |
360KVA |
384KVA |
450KVA |
480KVA |
Start Motor |
40HP |
50HP |
50HP |
60HP |
60HP |
80HP |
80HP |
Battery Voltage |
384VDC |
Size(L*W*Hmm) |
875*720*1380 |
1123*900*1605 |
Packing Size(L*W*Hmm) |
980*825*1560 |
1185*960*1750 |
N.W.(kg) |
512 |
592 |
612 |
612 |
642 |
705 |
755 |
G.W.(kg)(Wooden Packing) |
552 |
632 |
652 |
652 |
692 |
755 |
805 |
INPUT |
DC Input Voltage Range |
10.5VDC-15VDC(Single battery voltage) |
AC Input Voltage Range |
380Vac/400Vac±10%(customized 190Vac/200Vac) |
AC Input Frequency Range |
45Hz-55Hz(50Hz)/ 55Hz-65Hz(60Hz) |
Max AC charging current |
0-45A(Depending on the model) |
AC charging method |
Three-stage (constant current, constant voltage, floating charge) |
Phase |
3 PHASE |
OUTPUT |
Efficiency(Battery Mode) |
≥85% |
Output Voltage(Battery Mode) |
380Vac/400Vac±10%(customized 190Vac/200Vac) |
Output Frequency(Battery Mode) |
50/60Hz ±1% |
Output Wave(Battery Mode) |
Pure Sine Wave |
Output waveform distortion |
Linear load≤3% |
Efficiency(AC Mode) |
>99% |
Output Voltage(AC Mode) |
Conforming to AC input |
Output Frequency(AC Mode) |
Conforming to AC input |
No load loss(Battery Mode) |
≤1% rated power |
No load loss(AC Mode) |
≤2%rated power( charger does not work in AC mode) |
No load loss
(Energy saving Mode) |
≤10W |
Phase |
3 PHASE |
BATTERY |
VRLA Battery |
Charge Voltage :13.8V; Float Voltage:13.7V(Single battery voltage) |
Customize battery |
Charging and discharging parameters of different types of batteries can be customized according to user requirements |
(charging and discharging parameters of different types of batteries can be set through the operation panel) |
Protection |
Battery undervoltage alarm |
11V(Single battery voltage) |
Battery undervoltage protection |
10.5V(Single battery voltage) |
Battery overvoltage alarm |
15V(Single battery voltage) |
Battery overvoltage protection |
17V(Single battery voltage) |
Battery overvoltage recovery voltage |
14.5V(Single battery voltage) |
Overload power protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Inverter output short circuit protection |
Automatic protection (battery mode), circuit breaker or insurance (AC mode) |
Temperature protection |
>90°C(Shut down output) |
Alarm |
A |
Normal working condition, buzzer has no alarm sound |
B |
Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection |
C |
When the machine is turned on for the first time, the buzzer will prompt 5
when the machine is normal |
Inside Solar controller |
Charging Mode |
MPPT or PWM |
(Optional) |
Charging current |
PWM: 100A-200A / MPPT: 50A/100A |
|
PV Input Voltage Range |
PWM: 480V-704V / MPPT: 480V-640V |
|
Max PV Input Voltage(Voc) |
PWM: 750V / MPPT: 800V |
|
(At the lowest temperature) |
|
PV Array Maximum Power |
PWM: 44.8KW(100A)/33.6KW*2(150A)/44.8KW*2(200A)) / (MPPT: 22.4KW(50A)/22.4KW*2(100A) |
|
Standby loss |
≤3W |
|
Maximum conversion efficiency |
>95% |
Working Mode |
Battery First/AC First/Saving Energy Mode |
Transfer Time |
≤4ms |
Display |
LCD |
Thermal method |
Forced Air Cooling |
Communication(Optional) |
RS485/APP(WIFI monitoring or GPRS monitoring) |
Environment |
Operating temperature |
-10℃~40℃ |
Storage temperature |
-15℃~60℃ |
Noise |
2000m(More than derating) |
Elevation |
≤65dB |
Humidity |
0%~95% ,No condensation |
|