Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
f | Shipped From Abroad
Features:
- DSP digital control technology enables UPS more stable performance-+
- Environment friendly eco-designed
- Active input power factor correction
- Wide range of input voltage and frequency
- Zero power switch delay
- Adaptive Load Management.
- Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
- Support the generator
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
1)19 inches standard design of rack mount, compact structure.
2)Sin wave output provides best power supply guarantee.
3)Zero transfer time between mains mode and battery mode.
4)Detection function of input neutral wire and live wire.
5)Having voltage surge protection function and strong anti-interference function.
6)Equipped with correction function of input power factor
7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- True Double conversion Technology
- DSP digital control technology enable UPS more stable performance.
- Three Level inverter control technology
- Large screen LCD display
- N+X Parallel Redundancy function (3 units parallel)
- EPO emergency stop function
- Smart expansion Slots (optional)
- Support Generator
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | Features:
- Capacity: 2200W 2048Wh /640000mAh
- Input AC Output Power:Rated Power 2400W Peak Power 4800W
- Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
- Input Car Charging:DC12V~24V/10A 240W Max
- Input Solar Charging:DC16V~60V/10A 500W Max
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*QC18W+PD27W+PD100W Max
- DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support ; Battery Expandable: Support
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
| Features:
Nomimal voltage: 12V
Rated Capacity: 5Ah ~ 250Ah
Operating temperature range: -15 ~ 45 ℃
The design life is 5 years
Using new special process sheet formula to improve the utilization of active material
Using high quality superfine glass fiberliquid-suction battery technology to exceed 99% gas recombination rate
High-strength ABS plastic battery slot and cover with features of compact structure, corrosion resistant, impact resistance and
anti-vibration and so on
Small internal impedance, excellent performance when high current discharge
Low self-discharge, wide operating temperature range
Using multiple sealing technologies to ensure no leakage, no acid mist escaping to keep safe and reliable
Using strict production process, unit voltage balance is strong
Free maintenance, without adding water rehydration
Technical Specifications
Model |
Nominal Voltage |
Capacity |
Dimension LXWXH (mm) |
Total Height
(mm) |
Weight (KG) |
Terminal |
VL12-24 |
12 |
24 |
166 |
175 |
125 |
125 |
8 |
M6 |
VL12-28 |
12 |
28 |
166 |
175 |
125 |
125 |
9 |
M6 |
VL12-33 |
12 |
33 |
196 |
130 |
163 |
180 |
10 |
M6 |
VL12-35 |
12 |
35 |
197 |
130 |
163 |
180 |
10.5 |
M6 |
VL12-40 |
12 |
40 |
197 |
166 |
171 |
171 |
13.5 |
M6 |
VL12-44 |
12 |
44 |
196 |
166 |
171 |
171 |
13.5 |
M6 |
VL12-55 |
12 |
55 |
230 |
138 |
211 |
229 |
17.2 |
M6 |
VL12-65 |
12 |
65 |
350 |
166 |
179 |
179 |
22 |
M6 |
VL12-70 |
12 |
70 |
260 |
169 |
211 |
229 |
23 |
M8 |
VL12-80 |
12 |
80 |
260 |
169 |
211 |
229 |
24 |
M8 |
VL12-90 |
12 |
90 |
307 |
169 |
211 |
234 |
28 |
M8 |
VL12-100 |
12 |
100 |
331 |
173 |
213 |
233 |
32 |
M8 |
VL12-120 |
12 |
120 |
407 |
174 |
209 |
233 |
3, 8 |
M8 |
VL12-130 |
12 |
134 |
341 |
173 |
283 |
287 |
41 |
M8 |
VL12-150 |
12 |
150 |
484 |
171 |
241 |
241 |
46 |
M8 |
VL12-160 |
12 |
160 |
534 |
209 |
216 |
237 |
52 |
M8 |
VL12-180 |
12 |
180 |
530 |
209 |
216 |
237 |
56 |
M8 |
VL12-200 |
12 |
200 |
522 |
240 |
220 |
244 |
64 |
M8 |
VL12-230 |
12 |
230 |
520 |
268 |
220 |
240 |
72.5 |
M8 |
VL12-250 |
12 |
250 |
520 |
268 |
220 |
249 |
76 |
M8 |
| Features:
- DSP digital control technology enables UPS more stable performance-+
- Environment friendly eco-designed
- Active input power factor correction
- Wide range of input voltage and frequency
- Zero power switch delay
- Adaptive Load Management.
- Sufficient Expansion Slots: USB ,RS485 ,AS400 SNMP cards(Optional)
- Support the generator
Specifications:
Model |
33VT 10K |
33VT 10KL |
33VT 20K |
33VT 20KL |
33VT 30KL |
33VT 40KL |
Capacity |
10KVA/9000W |
20KVA/18KW |
30KVA/27KW |
40KVA/36KW |
Input |
Nominal Voltage |
380/400/415Vac |
Voltage Range |
207-475VAC(3P4W+G) |
Current |
14A |
28A |
42A |
67A |
Frequency |
40-70Hz (Adjustable) |
Power Factor |
≥0.99 |
Output |
Voltage |
380VAC 1±1% (3P4W+G) |
Frequency |
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz -54-60Hz);50Hz(Battery mode) |
Current |
15A |
30A |
45A |
61A |
Power Factor |
0.9 |
Crest Factor |
3:1 |
THD |
Line load <3% |
Chrage Current |
5.5A |
1A |
7.5A |
1A |
5.5A |
Battery Nominal Voltage |
192VDC |
±192VDC |
Transfer Time |
0ms |
Overload Capacity |
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass |
Communication |
SNMP,RS-232,USB+lntelligent Slot |
Operating Environment |
Temperature |
0°C~40°C |
Humidity |
20%~95% |
Dimension |
Width (mm) |
260 |
260 |
260 |
260 |
Depth (mm) |
560 |
533 |
710 |
560 |
Height (mm) |
717 |
501 |
717 |
717 |
Net Weight(Kg) |
26 |
72 |
57.5 |
98 |
58.5 |
62 |
| Features:
1)19 inches standard design of rack mount, compact structure.
2)Sin wave output provides best power supply guarantee.
3)Zero transfer time between mains mode and battery mode.
4)Detection function of input neutral wire and live wire.
5)Having voltage surge protection function and strong anti-interference function.
6)Equipped with correction function of input power factor
7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.
Technical Specifications
Model |
RTX3110KL |
RTX3115KL |
RTX3120KL |
Rated Power |
10kVA/9kW |
15kVA/13.5kW |
20kVA/18kW |
INPUT |
Voltage Range |
207-475Vac3P4W+G |
Working Frequency Range |
40-70HZ (settable) |
Input Power Factor |
>0.95 |
OUTPUT |
Rated Voltage and Accuracy |
220Vac(l±l%)lP2W+G |
Output Frequency |
46-54Hz synchronize with mains power; 50Hz (Mains power between 40-46Hz and 54-60Hz); 50Hz(Battery) |
Rated Current |
45A |
68A |
91A |
Output Power Factor |
0.9 |
Output Harmonic Wave |
W3% |
Crest Factor |
3:1 |
Output Overload |
105%±5%<Load≤125%±5%: Convert to bypass output and alarm after 1 min;
125%±5%<Load ≤50%±5%: Convert to bypass output and alarm after 30s;
Load>150%±5%: Convert to bypass output and alarm after 300ms. |
Transfer Time |
0ms |
Efficiency |
>92% |
BATTERY |
Rated Voltage |
192Vdc |
Quantity |
16 |
Charging Current |
5.5A |
Dimension (LxWxH) mm |
665*482.6*132.5 |
655*482.6*265 |
Weight |
23kg |
34kg |
35kg |
Working Temperature |
0°〜40°C |
Working Humidity |
20% 〜95% |
Noise |
≤60dB |
| Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Specifications
MODEL |
LF33 10K |
LF33 20K |
LF33 30K |
LF33 40K |
LF33 60K |
LF33 80K |
LF33 100K |
LF33 120K |
LF33 160K |
LF33 200K |
CAPACITY |
10KVA /8KW |
20KVA /16KW |
30KVA /24KW |
40KVA /32KW |
60KVA /48KW |
80KVA /64KW |
100KVA /80KW |
120KVA /96KW |
160KVA /128KW |
200KVA /160KW |
INPUT |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Acceptable Voltage Range |
305VAC ~ 460VAC |
Frequency |
46-54Hzor56-64Hz |
INVERTER |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Precision |
Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) |
Frequency |
50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load) ; <5% (Non-linear Load) |
Phase Displacement |
120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load) |
Dynamic Recovery Time |
Restore to 90% of rated value in 3 cycles |
Overload capacity |
110% for 10min; 150% for 60sec; >160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ 100% Unbalanced Load |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
Type |
Solid state |
Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Frequency |
50/60 Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissible Overload |
150% for 1 hour; 180% for 30sec; >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
Type |
Without interruption |
Voltage |
3 * 400V (3Ph + N) |
Frequency |
50/60 Hz |
Overall Efficiency |
Line Mode |
90% |
91% |
92% |
93% |
Battery Mode |
90% |
91% |
93% |
93% |
BATTERY & CHARGER |
Battery Type and Numbers |
12VDC * 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Max.: 40 A |
Charging Voltage |
432 VDC (Based on 32pcs batteries) |
PHYSICAL |
Dimensions, D x W x H(mm) |
656 x 405 x 817 |
656 x 405 x 941 |
840x432x1140 |
975x554x1286 |
1200x910x1680 |
1500x1140x1800 |
Net Weight (Kgs) |
180 |
205 |
295 |
330 |
451 |
519 |
950 |
1350 |
| Features:
- True Double conversion Technology
- DSP digital control technology enable UPS more stable performance.
- Three Level inverter control technology
- Large screen LCD display
- N+X Parallel Redundancy function (3 units parallel)
- EPO emergency stop function
- Smart expansion Slots (optional)
- Support Generator
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
Technical Specifications
Model |
VT6K |
VT6KL |
VT10K |
VT10KL |
31VT10KL |
31VT15KL |
31VT20KL |
Capacity |
6KVA/5400W |
10KVA/9000W |
15KVA/13.5KW |
20KVA/18KW |
Input |
Nominal Voltage |
220/230/240Vac |
380/400/415Vac |
Voltage Range |
120-275VAC(1P2W+G) |
207-475VAC(3P4W+G) |
Current |
31A (max) |
50A(max) |
50A (max) |
75A(max) |
100A(max) |
Frequency |
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode) |
Power Factor |
≥0.99· |
Output |
Voltage |
220/230/240±2%Vac (1P2W+G) |
Frequency |
50/60 Hz(adjustable)
50/60Hz± 5% (Line mode)
50/60Hz ± 0.05Hz ( Battery mode) |
Current |
27.3A |
45A |
68A |
91A |
Power Factor |
0.9 |
Waveform |
Pure Sine Wave |
Waveform Distortion |
Line load <2% |
Line load <3% |
Back-up Time |
Full Load |
≥7′ |
Depends on external batteries bank’s Capacity |
≥5′ |
Depends on external batteries bank’s Capacity |
Half Load |
≥20 |
≥13′ |
Battery Nominal Voltage |
192/240Vdc |
Transfer Time |
0ms |
Overload Capacity |
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass |
Communication |
SNMP,RS-232,USB+lntelligent Slot |
Operating Environment |
Temperature |
0°C~40°C |
Humidity |
15%~90% |
Dimension |
Width (mm) |
260 |
260 |
260 |
260 |
260 |
Depth (mm) |
560 |
533 |
560 |
533 |
560 |
Height (mm) |
717 |
501 |
717 |
501 |
717 |
Net Weight(Kg) |
55 |
12.2 |
62 |
21 |
23 |
32 |
33 |
|
Reviews
There are no reviews yet.