Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three Level inverter control technology
Large screen LCD display
N+X Parallel Redundancy function (3 units parallel)
EPO emergency stop function
Smart expansion Slots (optional)
Support Generator
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
Intelligent CPU control
Automatic power on when the the main power recovers
Cold start function
Power off charging function
USB/RS232/RJ-11/RJ-45 communication port (optional)
Offering LED and LCD panels for selection
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
Capacity: 2200W 2048Wh /640000mAh
Input AC Output Power:Rated Power 2400W Peak Power 4800W
Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
Input Car Charging:DC12V~24V/10A 240W Max
Input Solar Charging:DC16V~60V/10A 500W Max
Output Voltage:230VAC±10%/110VAC±10%
Output Frequency: 50Hz±5%/60Hz±5%
USB Output:2*QC18W+PD27W+PD100W Max
DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
Output Waveform:Pure Sine Wave
LED:3 Levels(H/M/L)+SOS
UPS Function:Support ; Battery Expandable: Support
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Features:
OPzV Tubular Gel Battery ( solid-state) 60AH-3000AH
Voltage class: 12V/2V
Capacity range: 60Ah~3000Ah
OPzV batteries offer high capacity reserve power and true deep cycling performance. With a design life of 20 years and a maintenance-free operation,
OPzV battery are perfect for regions with an unstable supply of electricity. OPzV battery are also completely spill-proof, which makes them safe to install anywhere,
even in remote environments with minimal supervision.
Technical Specifications
Model
Nominal Voltage
Capacity
Dimension
Terminal
C10/1.80VPC (Ah)
Length
Width
Height
Total Height
(V)
mm
mm
mm
mm
OPzV6-200
6
200
322
177.5
226
231
F16(M8)
F14(M8)
OPzV12-60
12
60
260
169
211
216
F11(M6)
OPzV12-80
12
80
328
172
215
220
F12(M8)
OPzV12-100
12
100
407
177
225
225
F12(M8)
OPzV12-120
12
120
483
170
241
241
F12(M8)
OPzV12-140
12
140
532
207
214
219
F12(M8)
OPzV12-160
12
160
532
207
214
219
F12(M8)
OPzV12-180
12
180
522
240
219
224
F10(M8)
OPzV12-200
12
200
521
268
220
225
F14(M8)
OPzV2-200
2
200
103
206
355
390
F10(M8)
OPzV2-250
2
250
124
206
355
390
F10(M8)
OPzV2-300
2
300
145
206
355
390
F10(M8)
OPzV2-350
2
350
124
206
470
505
F10(M8)
OPzV2-420
2
420
145
206
470
505
F10(M8)
OPzV2-500
2
490
166
206
470
505
F10(M8)
OPzV2-770
2
770
210
254
470
505
F10(M8)
OPzV2-600
2
600
145
206
645
680
F10(M8)
OPzV2-800
2
800
191
210
645
680
F10(M8)
OPzV2-1000
2
1000
233
210
645
680
F10(M8)
OPzV2-1200
2
1200
276
210
645
680
F10(M8)
OPzV2-1500
2
1500
275
210
795
830
F10(M8)
OPzV2-2000
2
2000
399
214
770
805
F10(M8)
OPzV2-2500
2
2500
487
212
770
805
F10(M8)
OPzV2-3000
2
3000
576
212
770
805
F10(M8)
Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three Level inverter control technology
Large screen LCD display
N+X Parallel Redundancy function (3 units parallel)
EPO emergency stop function
Smart expansion Slots (optional)
Support Generator
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Technical Specifications
Model
VT6K
VT6KL
VT10K
VT10KL
31VT10KL
31VT15KL
31VT20KL
Capacity
6KVA/5400W
10KVA/9000W
15KVA/13.5KW
20KVA/18KW
Input
Nominal Voltage
220/230/240Vac
380/400/415Vac
Voltage Range
120-275VAC(1P2W+G)
207-475VAC(3P4W+G)
Current
31A (max)
50A(max)
50A (max)
75A(max)
100A(max)
Frequency
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass
Communication
SNMP,RS-232,USB+lntelligent Slot
Operating Environment
Temperature
0°C~40°C
Humidity
15%~90%
Dimension
Width (mm)
260
260
260
260
260
Depth (mm)
560
533
560
533
560
Height (mm)
717
501
717
501
717
Net Weight(Kg)
55
12.2
62
21
23
32
33
Features:
Intelligent CPU control
Automatic power on when the the main power recovers
Cold start function
Power off charging function
USB/RS232/RJ-11/RJ-45 communication port (optional)
Offering LED and LCD panels for selection
Application:
Personal Computer
Printer
POS(Point of sales)Terminals
Security System
Fax Machine
Modem, WiFi Router
Technical Specifications:
Model
DP600
DP1000
DP1200
DP2000
DP3000
Capacity
600VA/360W
1000VA/600W
1200VA/720W
2000VA/1200W
3000VA/1800W
INPUT
Voltage
110/120VAA or 220/230/240VAC
Voltage Range
67-137VAC/135-275VAC
Frequency Range
50Hz Or 60Hz(Auto-Sensing)
OUTPUT
Output Voltage
110/120VAA or 220/230/240VAC
AC Voltage Regulation
± 10%
Frequency Range
(Batt. Mode)
50 HZ or 60 Hz ± 10%
Transfer Time
Typical 6-10 ms
Waveform
(Battery Mode)
Simulated Sine Wave
BATTERY
Battery Voltage
12V/7AH*1
12V/9AH*1
12V/7AH*2
12V/9AH*2
12V/7AH*4
Charge Time
8 hours up to 80-90%
PROTECTION
Full Protection
Auto Detection, discharge protection,output Short circuit, Over load, Battery low voltage protection
Communication Port
USB/RS232/RJ11/RJ45 (Optional)
Display
LED/LCD
Alarm
Battery Mode
Every 4 Seconds one beep
Low Battery Capacity
Every 1 Seconds one beep
Overload
Every 1 Seconds one beep
Fault
Keep beeping
ENVIRONMENT
Humidity
0-90% Rh @ 0-40℃ (Non-Condensing)
Noise Level
40dB
Dimension(mm)
320*90*140
330* 100*150
365*140*165
365*140*165
395*145*210
N.W.(kg)
5.2
6
10
12.6
21
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLYIGBT Technology
Full microprocessor control with no-break static and manual bypasses.
Online double conversion technology (VFl) with isolation transformer on theinverter output.
Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output.
Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world.
SIMPLE TO INSTALL
Capability to install the UPS into any distribution system(neutral not required on rectifier input).
Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer
MAXIMUM BATTERY CARE
Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.
OTHER CHARACTERISTICS
0.8/0.9 power factor suitable for powering ICT and lndustrial loads.
BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur.
MAXIMUM RELIABILITY AND AVAILABILITY
Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings.
The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP)
LOW CONSUMPTION LEVELS
LF33 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.
ADVANCE COMMUNICATION:
RS485/RS232/Dry Contact/SNMP(Optional)
Specifications
Model
10KVA
20KVA
30KVA
40KVA
60KVA
80KVA
100KVA
120KVA
160KVA
200KVA
250KVA
300KVA
400KVA
500KVA
600KVA
Capacity
8KW
16 KW
24 KW
32 KW
48 KW
64 KW
80 KW
96 KW
128 KW
160 KW
200KW
240KW
320KW
400KW
480KW
INPUT
Rated voltage
400 VAC Three-Phase
Voltage range
380/400/415VAC(+25%,Can be set through the LCD panel)
Frequency range
40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ)
50±5%(±10%) Bypass synchronization tracking
Rectifying pulse number
6 pulse rectification
6/12 pulse rectification
12 pulse rectifier
Phase system
3φ4W+PE(Three phase five wire system)
Battery voltage
384VDC
480VDC
Battery Quantity
Standard with 32 Cells(30~34, can be set through the LCD panel) Standard 40 Cells(38~42 knots,can be set by LCD panel)
OUTPUT
Power factor
0.8/0.9 (Optional)
Voltage(V)
L-N: 220±1% L-L: 380±1%
Three-phase 100% load
unbalance voltage stability
≤2%,Allow 100% imbalance
Frequency(HZ)
Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms)
0ms
Parallel operation mode
(parallel type)
Max 8 Parallel
Waveform distortion
Linear loadTHD<3% ; Nonlinear loadTHD<5%
Overload capacity
125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply,
after reducing the loadcan automatically restore the inverter
Crest factor
3:1
Others
Index
Standard with no transfer time maintenance bypass switch
Communication function
RS232/RS485/Dry Contact/SNMP (Optional)
Panel display
LED displays working status and fault indication; LCD displays three-phase input voltage,
input frequency, three-phase output voltage, load,battery voltage, battery charge and discharge current, etc
Display
7″ Touchable LCD screen display
The audio noise(dB)
<65(within 1 meter)
Alarm function
Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
Protection
Input over voltage, battery under voltage, overload, short circuit, over temperature protection
Reviews