Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three Level inverter control technology
Large screen LCD display
N+X Parallel Redundancy function (3 units parallel)
EPO emergency stop function
Smart expansion Slots (optional)
Support Generator
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
1)19 inches standard design of rack mount, compact structure.
2)Sin wave output provides best power supply guarantee.
3)Zero transfer time between mains mode and battery mode.
4)Detection function of input neutral wire and live wire.
5)Having voltage surge protection function and strong anti-interference function.
6)Equipped with correction function of input power factor
7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
Optional 7 ” touch LCD
Online double-conversionDSP technology guarantees high reliability
True galvanic isolation transformer designControl designed to withstand all kinds of loads
Intelligent battery management to prolong battery lifecycle
Redundant fan design and independent ventilation enhance durable operation under harsh environment
Adiustable battery numbers
Accept dual-mains input
Parallel operation with up to 4 units ( option )
Variety of communication options available
Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
Capacity: 2200W 2048Wh /640000mAh
Input AC Output Power:Rated Power 2400W Peak Power 4800W
Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
Input Car Charging:DC12V~24V/10A 240W Max
Input Solar Charging:DC16V~60V/10A 500W Max
Output Voltage:230VAC±10%/110VAC±10%
Output Frequency: 50Hz±5%/60Hz±5%
USB Output:2*QC18W+PD27W+PD100W Max
DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
Output Waveform:Pure Sine Wave
LED:3 Levels(H/M/L)+SOS
UPS Function:Support ; Battery Expandable: Support
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three Level inverter control technology
Large screen LCD display
N+X Parallel Redundancy function (3 units parallel)
EPO emergency stop function
Smart expansion Slots (optional)
Support Generator
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Technical Specifications
Model
VT6K
VT6KL
VT10K
VT10KL
31VT10KL
31VT15KL
31VT20KL
Capacity
6KVA/5400W
10KVA/9000W
15KVA/13.5KW
20KVA/18KW
Input
Nominal Voltage
220/230/240Vac
380/400/415Vac
Voltage Range
120-275VAC(1P2W+G)
207-475VAC(3P4W+G)
Current
31A (max)
50A(max)
50A (max)
75A(max)
100A(max)
Frequency
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
105%±5%< Load<125%±5% :1 min transfer to bypass
125% ±5% < Load<135 % ±5 % :30s transfer to bypass
Load > 135 % ± 5 %: 300s transfer to bypass
Communication
SNMP,RS-232,USB+lntelligent Slot
Operating Environment
Temperature
0°C~40°C
Humidity
15%~90%
Dimension
Width (mm)
260
260
260
260
260
Depth (mm)
560
533
560
533
560
Height (mm)
717
501
717
501
717
Net Weight(Kg)
55
12.2
62
21
23
32
33
Features:
1)19 inches standard design of rack mount, compact structure.
2)Sin wave output provides best power supply guarantee.
3)Zero transfer time between mains mode and battery mode.
4)Detection function of input neutral wire and live wire.
5)Having voltage surge protection function and strong anti-interference function.
6)Equipped with correction function of input power factor
7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.
Technical Specifications
Model
RTX3110KL
RTX3115KL
RTX3120KL
Rated Power
10kVA/9kW
15kVA/13.5kW
20kVA/18kW
INPUT
Voltage Range
207-475Vac3P4W+G
Working Frequency Range
40-70HZ (settable)
Input Power Factor
>0.95
OUTPUT
Rated Voltage and Accuracy
220Vac(l±l%)lP2W+G
Output Frequency
46-54Hz synchronize with mains power; 50Hz (Mains power between 40-46Hz and 54-60Hz); 50Hz(Battery)
Rated Current
45A
68A
91A
Output Power Factor
0.9
Output Harmonic Wave
W3%
Crest Factor
3:1
Output Overload
105%±5%<Load≤125%±5%: Convert to bypass output and alarm after 1 min;
125%±5%<Load ≤50%±5%: Convert to bypass output and alarm after 30s;
Load>150%±5%: Convert to bypass output and alarm after 300ms.
Transfer Time
0ms
Efficiency
>92%
BATTERY
Rated Voltage
192Vdc
Quantity
16
Charging Current
5.5A
Dimension (LxWxH) mm
665*482.6*132.5
655*482.6*265
Weight
23kg
34kg
35kg
Working Temperature
0°〜40°C
Working Humidity
20% 〜95%
Noise
≤60dB
Features:
Optional 7 ” touch LCD
Online double-conversionDSP technology guarantees high reliability
True galvanic isolation transformer designControl designed to withstand all kinds of loads
Intelligent battery management to prolong battery lifecycle
Redundant fan design and independent ventilation enhance durable operation under harsh environment
Adiustable battery numbers
Accept dual-mains input
Parallel operation with up to 4 units ( option )
Variety of communication options available
Reverse phase frequency operation and supportsnon-neutral input
50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed
±1 Hz/s
Waveform
Pure Sinewave
Total Harmonic Distortion (THDv)
<2% (Linear Load) ; <5% (Non-linear Load)
Phase Displacement
120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load)
Dynamic Recovery Time
Restore to 90% of rated value in 3 cycles
Overload capacity
110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor
3:1
Admissible Power Factor
0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load
<1%
Current Limit
High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type
Solid state
Voltage
3 x 380VAC/400VAC (3Ph + N)
Frequency
50/60 Hz
Activation Criterion
Microprocessor control
Transfer Time
Zero
Admissible Overload
150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass
Immediate, for overloads above 160%
Retransfer
Automatic after alarm clear
MAINTENANCE BYPASS
Type
Without interruption
Voltage
3 * 400V (3Ph + N)
Frequency
50/60 Hz
Overall Efficiency
Line Mode
90%
91%
92%
93%
Battery Mode
90%
91%
93%
93%
BATTERY & CHARGER
Battery Type and Numbers
12VDC * 32 pcs (29-32 pcs adjustable)
Nominal Battery Voltage
384 VDC (Based on 32pcs batteries)
Charging Method
CC/CV
Precision
±1%
Charging Current
Max.: 40 A
Charging Voltage
432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm)
656 x 405 x 817
656 x 405 x 941
840x432x1140
975x554x1286
1200x910x1680
1500x1140x1800
Net Weight (Kgs)
180
205
295
330
451
519
950
1350
Features:
Rated Power: 1000W
Rated Capacity: 932.4wh
Standard Capacity: 3.7V/252000mah
Overload Protecion: 1050+40W
AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
Output Wave: Pure sine wave
USB Output: QC 18W*2
Type-c Output: PD 60W*2
Cigarret Lighter Output: 14V/8A
DC5525 Output: 14V/8A
Wireless Charging: 15W
Charging Input: 12-26 V/150W Max
WorkingTemperature: -10-40 °C
Weight(Net Weight): 8. 2kg
Weight(With Accessories): 10.2kg
Dimension: 345*227*203mm
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Description
HIGH INTELLIGENCE AND RELIABLE POWER SUPPLYIGBT Technology
Full microprocessor control with no-break static and manual bypasses.
Online double conversion technology (VFl) with isolation transformer on theinverter output.
Extremely high short-circuit current to ensure compatibility with the most diffificult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output.
Compatibled with Watch & Save 3000 software as standard and can be remotely monitored using the Power NetGuard system from anywhere in the world.
SIMPLE TO INSTALL
Capability to install the UPS into any distribution system(neutral not required on rectifier input).
Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic isolation(Necessary on UPS without an output transformer
MAXIMUM BATTERY CARE
Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.
OTHER CHARACTERISTICS
0.8/0.9 power factor suitable for powering ICT and lndustrial loads.
BACK FEED protection: to avoid energy feeding back into the mains supply cause a fault occur.
MAXIMUM RELIABILITY AND AVAILABILITY
Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings.
The UPS continue to work in parallel even if one of theinterconnecting communication cables is disconnected(CLOSED LOOP)
LOW CONSUMPTION LEVELS
LF31 Series UPS can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.
ADVANCE COMMUNICATION:
RS485/RS232/Dry Contact/SNMP(Optional)
Specifications
Model
10KVA
15KVA
20KVA
30KVA
40KVA
60KVA
80KVA
100KVA
Capacity
8KW
12 KW
16 KW
24 KW
32 KW
48 KW
64 KW
80 KW
INPUT
Rated voltage
380/400/415 VAC Three-phase
Voltage range
±20%
Frequency range
45-65Hz
Power factor
>0.92 with harmonic filter
Current harmonic distortion
<5% with harmonic filter
Soft Start
0 -100% in 10″
BYPASS INPUT
Rated voltage
230VAC Single Phase
Permitted voltage range
±15% (selectable from ±10% to ±25% from front panel)
Reviews