Description | Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
1)19 inches standard design of rack mount, compact structure.
2)Sin wave output provides best power supply guarantee.
3)Zero transfer time between mains mode and battery mode.
4)Detection function of input neutral wire and live wire.
5)Having voltage surge protection function and strong anti-interference function.
6)Equipped with correction function of input power factor
7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
Content | Features:
- Capacity: 2200W 2048Wh /640000mAh
- Input AC Output Power:Rated Power 2400W Peak Power 4800W
- Input AC Charging:AC100~125V/AC174~264V Bidirectional Inverter 1400W Max
- Input Car Charging:DC12V~24V/10A 240W Max
- Input Solar Charging:DC16V~60V/10A 500W Max
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*QC18W+PD27W+PD100W Max
- DC Output:1*Cigarette Lighter 12.8V/12A Max+2*DC5521 Rated Output 12.8V/5A Max
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support ; Battery Expandable: Support
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
| Features:
1)19 inches standard design of rack mount, compact structure.
2)Sin wave output provides best power supply guarantee.
3)Zero transfer time between mains mode and battery mode.
4)Detection function of input neutral wire and live wire.
5)Having voltage surge protection function and strong anti-interference function.
6)Equipped with correction function of input power factor
7) Supporting mobile smart monitoring card , users can real-time monitor every data of the UPS by mobile APP.
Technical Specifications
Model |
RTX3110KL |
RTX3115KL |
RTX3120KL |
Rated Power |
10kVA/9kW |
15kVA/13.5kW |
20kVA/18kW |
INPUT |
Voltage Range |
207-475Vac3P4W+G |
Working Frequency Range |
40-70HZ (settable) |
Input Power Factor |
>0.95 |
OUTPUT |
Rated Voltage and Accuracy |
220Vac(l±l%)lP2W+G |
Output Frequency |
46-54Hz synchronize with mains power; 50Hz (Mains power between 40-46Hz and 54-60Hz); 50Hz(Battery) |
Rated Current |
45A |
68A |
91A |
Output Power Factor |
0.9 |
Output Harmonic Wave |
W3% |
Crest Factor |
3:1 |
Output Overload |
105%±5%<Load≤125%±5%: Convert to bypass output and alarm after 1 min;
125%±5%<Load ≤50%±5%: Convert to bypass output and alarm after 30s;
Load>150%±5%: Convert to bypass output and alarm after 300ms. |
Transfer Time |
0ms |
Efficiency |
>92% |
BATTERY |
Rated Voltage |
192Vdc |
Quantity |
16 |
Charging Current |
5.5A |
Dimension (LxWxH) mm |
665*482.6*132.5 |
655*482.6*265 |
Weight |
23kg |
34kg |
35kg |
Working Temperature |
0°〜40°C |
Working Humidity |
20% 〜95% |
Noise |
≤60dB |
| Features:
- True double-conversion
- LCD screen auto-rotation with Rack position ( only for 10K-20K models)
- DSP technology guarantees high performance
- Output power factor 1
- Support 1/1;3/1;3/3 Phase Adjustable
- Active power factor correction in all phases
- 50HZ / 60HZ frequency converter mode
- ECO mode operation for energy saving ( ECO)
- Emergency power off function ( EPO)
- Generator compatible
- Supports dual AC inputs
- 3-stage extendable charging design for optimized battery performance
- Adjustable battery numbers for long-run model
- Supporting Parallel sharing of battery packs
- Optional isolation transformer offers full isolation and complete common mode noise rejection
- Support with SNMP,USB, RS232 communication
Technical Specifications
MODEL |
33RM 10KL |
33RM 15KL |
33RM 20KL |
33RM 30KL |
33RM 40KL |
33RM 60KL |
CAPACITY |
10KVA/10KW |
15KVA/15KW |
20KVA/20KW |
30KVA/30KW |
40KVA/40KW |
60KVA/60KW |
PHASE |
3 Phase input / 3 Phase output |
PARALLEL CAPABILITY |
4 Max |
INPUT |
Nominal Voltage |
3×380 VAC (3Ph+N) |
Voltage Range |
190-520 VAC (3 Phase) @ 50% load , 305-478 VAC (3 Phase) @ 100% load |
Frequency Range |
46-54 Hz or 56~64Hz |
Power Factor |
≥ 0.99 @ 100% load |
OUTPUT |
Output Voltage |
3 x 360*/380/400/415 VAC (3Ph+N) |
AC Voltage Regulation (Batt. Mode) |
± 1% |
Frequency Range (Synchronized Range) |
46~54Hz or 56~64Hz |
Frequency Range (Batt. Mode) |
50 Hz ±0.1 Hz or 60 Hz ±0.1 Hz |
Current Crest Ratio |
3:1 (max.) |
Harmonic Distortion |
≤1 % THD (Linear Load), ≤3% THD (Non-linear Load) |
Transfer Time |
AC mode to Battery mode |
zero |
Inverter to Bypass |
zero |
Waveform (Batt. Mode) |
Pure Sine Wave |
Overload |
AC Mode |
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection |
Battery Mode |
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection |
EFFICIENCY |
AC Mode |
95.5% |
ECO Mode |
98.5% |
Battery Mode |
94.5% |
BATTERY |
Battery Type |
Depending on the applications |
Numbers |
20 pcs |
32-40 pcs (Adjustable) |
Charging Current (max.) |
1A~ 12A (Adjustable) |
1A~ 16A (Adjustable) |
1A 〜18A (Adjustable) |
Charging Voltage |
±13.65 VDCx N (N=10) |
±13.65VxN (N=16〜20) |
PHYSICAL |
Dimension, D * W * H (mm) |
680*438*133 [3U] |
797*438*176 [4U] |
Net Weight (kgs) |
27 |
30 |
40 |
45 |
ENVIRONMENT |
Operation Temperture |
0-40°C |
Operation Humidity |
0-95% and non-condersing |
Noise Level |
Less than 62dB @ 1 Meter |
Less than 65dB @ 1 Meter |
Less than 70dB @ 1 Meter |
MANAGEMENT |
Smart RS-232/USB |
Supports Windows® Family, Linux and MAC |
Optional SNMP |
Power management from SNMP manager and web browser |
| Features:
- Capacity: 1200W 1008Wh /315000mAh
- Input AC Output Power:Rated Power 1200W Peak Power 2400W
- Input AC Charging:AC100~125V/AC184~264V Bidirectional Inverter 700W Max
- Input Car Charging:DC12V~24V/10A 240W Max
- Input Solar Charging:DC12V~60V/10A 400W Max
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*5V2.4A +2*QC18W+2*PD60W Max
- DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support(≤10mS)
Applications:
- Mammogram
- Ultrasound Equipments
- Radiology rooms
| Features:
- Optional 7 ” touch LCD
- Online double-conversionDSP technology guarantees high reliability
- True galvanic isolation transformer designControl designed to withstand all kinds of loads
- Intelligent battery management to prolong battery lifecycle
- Redundant fan design and independent ventilation enhance durable operation under harsh environment
- Adiustable battery numbers
- Accept dual-mains input
- Parallel operation with up to 4 units ( option )
- Variety of communication options available
- Reverse phase frequency operation and supportsnon-neutral input
Specifications
MODEL |
LF33 10K |
LF33 20K |
LF33 30K |
LF33 40K |
LF33 60K |
LF33 80K |
LF33 100K |
LF33 120K |
LF33 160K |
LF33 200K |
CAPACITY |
10KVA /8KW |
20KVA /16KW |
30KVA /24KW |
40KVA /32KW |
60KVA /48KW |
80KVA /64KW |
100KVA /80KW |
120KVA /96KW |
160KVA /128KW |
200KVA /160KW |
INPUT |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Acceptable Voltage Range |
305VAC ~ 460VAC |
Frequency |
46-54Hzor56-64Hz |
INVERTER |
Nominal Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Precision |
Stationary: ±1% Transitory: ±5% (load variations 100-0-100%) |
Frequency |
50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz |
Max. Synchronisation Speed |
±1 Hz/s |
Waveform |
Pure Sinewave |
Total Harmonic Distortion (THDv) |
<2% (Linear Load) ; <5% (Non-linear Load) |
Phase Displacement |
120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load) |
Dynamic Recovery Time |
Restore to 90% of rated value in 3 cycles |
Overload capacity |
110% for 10min; 150% for 60sec; >160% for 200ms |
Admissible Crest Factor |
3:1 |
Admissible Power Factor |
0.6-1 (inductive or capacitive) |
Imbalance Output Voltage @ 100% Unbalanced Load |
<1% |
Current Limit |
High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit |
STATIC BYPASS |
Type |
Solid state |
Voltage |
3 x 380VAC/400VAC (3Ph + N) |
Frequency |
50/60 Hz |
Activation Criterion |
Microprocessor control |
Transfer Time |
Zero |
Admissible Overload |
150% for 1 hour; 180% for 30sec; >200% for 200ms |
Transfer to Bypass |
Immediate, for overloads above 160% |
Retransfer |
Automatic after alarm clear |
MAINTENANCE BYPASS |
Type |
Without interruption |
Voltage |
3 * 400V (3Ph + N) |
Frequency |
50/60 Hz |
Overall Efficiency |
Line Mode |
90% |
91% |
92% |
93% |
Battery Mode |
90% |
91% |
93% |
93% |
BATTERY & CHARGER |
Battery Type and Numbers |
12VDC * 32 pcs (29-32 pcs adjustable) |
Nominal Battery Voltage |
384 VDC (Based on 32pcs batteries) |
Charging Method |
CC/CV |
Precision |
±1% |
Charging Current |
Max.: 40 A |
Charging Voltage |
432 VDC (Based on 32pcs batteries) |
PHYSICAL |
Dimensions, D x W x H(mm) |
656 x 405 x 817 |
656 x 405 x 941 |
840x432x1140 |
975x554x1286 |
1200x910x1680 |
1500x1140x1800 |
Net Weight (Kgs) |
180 |
205 |
295 |
330 |
451 |
519 |
950 |
1350 |
| Features:
- Capacity: 600W 512Wh /160000mAh
- Input AC Output Power:Rated Power 600W Peak Power 1200W
- Input AC Charging:AC100~120V/AC200~240V Built-in 200W
- Input Car Charging:DC12V~24V/7A Max 120W Max
- Input Solar Charging:DC12V~24V/120WMax
- Output Voltage:230VAC±10%/110VAC±10%
- Output Frequency: 50Hz±5%/60Hz±5%
- USB Output:2*QC24W+PD27W+PD100W Max
- DC Output:1*Cigarette Lighter+2*DC5521 Rated Output (13.8V/10A Max)
- Output Waveform:Pure Sine Wave
- LED:3 Levels(H/M/L)+SOS
- UPS Function:Support(≤10mS)
Applications:
- Mammogram
- Ultrasound Equipments