Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
Optional 7 ” touch LCD
Online double-conversionDSP technology guarantees high reliability
True galvanic isolation transformer designControl designed to withstand all kinds of loads
Intelligent battery management to prolong battery lifecycle
Redundant fan design and independent ventilation enhance durable operation under harsh environment
Adiustable battery numbers
Accept dual-mains input
Parallel operation with up to 4 units ( option )
Variety of communication options available
Reverse phase frequency operation and supportsnon-neutral input
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three-level inverter technology
Active High input power factor correction technology (PFC)
Wide Input Voltage Frequency Range& Strong load capacity
Zero power switch delay
Compatible with Generators
Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
Support intelligent monitoring
Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Features:
Wide AC input voltage range 85~265Vac.
Inbuilt 4* 2600mah lithium battery to support longer power supply for loads.
DC output interfaces support USB (5V) /9V/12V/ 15V/24V (POE)
Ethernet power supply: one network cable can transmit data and electric
power at the same time.
Over-charging, Over-discharging and Short Circuit protection
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features:
Rated Power: 1000W
Rated Capacity: 932.4wh
Standard Capacity: 3.7V/252000mah
Overload Protecion: 1050+40W
AC Output: AC 110V+10%/60HZ 230V+10%/50HZ
Output Wave: Pure sine wave
USB Output: QC 18W*2
Type-c Output: PD 60W*2
Cigarret Lighter Output: 14V/8A
DC5525 Output: 14V/8A
Wireless Charging: 15W
Charging Input: 12-26 V/150W Max
WorkingTemperature: -10-40 °C
Weight(Net Weight): 8. 2kg
Weight(With Accessories): 10.2kg
Dimension: 345*227*203mm
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Features:
Optional 7 ” touch LCD
Online double-conversionDSP technology guarantees high reliability
True galvanic isolation transformer designControl designed to withstand all kinds of loads
Intelligent battery management to prolong battery lifecycle
Redundant fan design and independent ventilation enhance durable operation under harsh environment
Adiustable battery numbers
Accept dual-mains input
Parallel operation with up to 4 units ( option )
Variety of communication options available
Reverse phase frequency operation and supportsnon-neutral input
50/60 Hz synchronised ±1 % With mains absent ±0.1 Hz
Max. Synchronisation Speed
±1 Hz/s
Waveform
Pure Sinewave
Total Harmonic Distortion (THDv)
<2% (Linear Load) ; <5% (Non-linear Load)
Phase Displacement
120° ±1 % (balanced load); 120° ±2% (imbalances 50% of the load)
Dynamic Recovery Time
Restore to 90% of rated value in 3 cycles
Overload capacity
110% for 10min; 150% for 60sec; >160% for 200ms
Admissible Crest Factor
3:1
Admissible Power Factor
0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load
<1%
Current Limit
High overload, short-circuit: RMS Voltage Limit; High Crest-Factor current: Peak Voltage Limit
STATIC BYPASS
Type
Solid state
Voltage
3 x 380VAC/400VAC (3Ph + N)
Frequency
50/60 Hz
Activation Criterion
Microprocessor control
Transfer Time
Zero
Admissible Overload
150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass
Immediate, for overloads above 160%
Retransfer
Automatic after alarm clear
MAINTENANCE BYPASS
Type
Without interruption
Voltage
3 * 400V (3Ph + N)
Frequency
50/60 Hz
Overall Efficiency
Line Mode
90%
91%
92%
93%
Battery Mode
90%
91%
93%
93%
BATTERY & CHARGER
Battery Type and Numbers
12VDC * 32 pcs (29-32 pcs adjustable)
Nominal Battery Voltage
384 VDC (Based on 32pcs batteries)
Charging Method
CC/CV
Precision
±1%
Charging Current
Max.: 40 A
Charging Voltage
432 VDC (Based on 32pcs batteries)
PHYSICAL
Dimensions, D x W x H(mm)
656 x 405 x 817
656 x 405 x 941
840x432x1140
975x554x1286
1200x910x1680
1500x1140x1800
Net Weight (Kgs)
180
205
295
330
451
519
950
1350
Features:
True Double conversion Technology
DSP digital control technology enable UPS more stable performance.
Three-level inverter technology
Active High input power factor correction technology (PFC)
Wide Input Voltage Frequency Range& Strong load capacity
Zero power switch delay
Compatible with Generators
Wide input voltage and frequency range can effectively isolate the harmful waves into power by the generator and provide pure,safe and stable power supply.
Support intelligent monitoring
Fully support remote intelligent monitoring with flexibility in choice of USB cards . AS400 cards , SNMP cards , RS485 cards
Applications:
Mammogram
Ultrasound Equipments
Radiology rooms
Technical Specifications
Model
VT1K
VT1KL
VT2K
VT2KL
VT3K
VT3KL
Rated power
1KVA/900KW
2KVA/1.8KW
3KVA/2.7KW
Input
Voltage range
90~285Vac L+N+G
Frequency range
40-70Hz(Adjustable)
Input power factor
>0.99
Output
Rated voltage and precision
220Vac (1±2% ) L+N+G
Output frequency
46-54Hz Synchronous mains power; 50Hz( Frequency Range 40-46Hz ~54-60Hz);50Hz(Battery mode)
Rated Current
4.5A
9.1A
13.6A
Output power factor
0.9
Output harmonic
≤4%
Crest factor
3:1
Inverter overload capacity
105%±5%< Load<125%±5% : 50s transfer to bypass
125% ±5% < Load<150 % ±5 % : 25s transfer to bypass
Load > 150 % ± 5 %: 300s transfer to bypass
Transfer time
0ms
Efficiency
≥85%
Battery
Rated voltage
24Vdc
36Vdc
48Vdc
72Vdc
72Vdc
96Vdc
Battery Numbers
2
3
4
6
6
8
Charge current
1A
6.5A
1A
5.5A
1A
5.5A
Size(LXWXH)mm
350*144*230
425*190*328
Net Weight(KG)
9.5kg
6kg
18.5kg
10kg
23.5kg
11kg
Operating temperature
0°C 〜40°C
Operating humidity
20% 〜95%
Noise
≤50dB
Features:
Wide AC input voltage range 85~265Vac.
Inbuilt 4* 2600mah lithium battery to support longer power supply for loads.
DC output interfaces support USB (5V) /9V/12V/ 15V/24V (POE)
Ethernet power supply: one network cable can transmit data and electric
power at the same time.
Over-charging, Over-discharging and Short Circuit protection
Specifications
Model
DC 1018P
DC 1036P
INPUT
Input Voltage
85 – 265Vac
Output
DC Output Voltage
5V 2A
5V 2A
USB 2A
USB 2A
9V 1A
9V 1A
12V 1A
12V 1A
15V/24V(POE) 0.5A
15V/24V(POE) 0.5A
18W
36W
BATTERY
Battery Type
Lithium Battery
Capacity of Battery
2600mAh * 4
PROTECTION
Protect
Over-charging, Over-discharging and Short Circuit
ENVIRNMENT
Operation Temperature
0°C – 40°C
Noise Level
Less than 40dB
Dimension(mm)
160 * 105 * 33
Net Weight(kg)
0.40
0.42
Features:
True double-conversion
LCD screen auto-rotation with Rack position ( only for 10K-20K models)
DSP technology guarantees high performance
Output power factor 1
Support 1/1;3/1;3/3 Phase Adjustable
Active power factor correction in all phases
50HZ / 60HZ frequency converter mode
ECO mode operation for energy saving ( ECO)
Emergency power off function ( EPO)
Generator compatible
Supports dual AC inputs
3-stage extendable charging design for optimized battery performance
Adjustable battery numbers for long-run model
Supporting Parallel sharing of battery packs
Optional isolation transformer offers full isolation and complete common mode noise rejection
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
Battery Mode
100-110% for 60 min, 110-125% for 10 min, 125%~150% for 1 min; >150% immediately Protection
EFFICIENCY
AC Mode
95.5%
ECO Mode
98.5%
Battery Mode
94.5%
BATTERY
Battery Type
Depending on the applications
Numbers
20 pcs
32-40 pcs (Adjustable)
Charging Current (max.)
1A~ 12A (Adjustable)
1A~ 16A (Adjustable)
1A 〜18A (Adjustable)
Charging Voltage
±13.65 VDCx N (N=10)
±13.65VxN (N=16〜20)
PHYSICAL
Dimension, D * W * H (mm)
680*438*133 [3U]
797*438*176 [4U]
Net Weight (kgs)
27
30
40
45
ENVIRONMENT
Operation Temperture
0-40°C
Operation Humidity
0-95% and non-condersing
Noise Level
Less than 62dB @ 1 Meter
Less than 65dB @ 1 Meter
Less than 70dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB
Supports Windows® Family, Linux and MAC
Optional SNMP
Power management from SNMP manager and web browser
Features:
Three Phase Hybrid Solar Inverter
Off grid three phase solar hybrid inverter with pwm/mppt can be used in single-phase and three-phase ac load with total power not exceeding 100kva/120kva/125kva/150kva/160kva,384vdc to 380vac.
•Pure sine wave output.
•Low DC voltage, saving system cost.
•Three phase solar inverter with built-in PWM or MPPT charge controller.
•AC charge current 0-45A adjustable.
•Wide LCD screen, clearly and precisely shows icon data.
•100%imbalance loading design, 3 times peak power.
•Setting different working modes based on variable usage requirements.
•DC first/AC first optional.
•Various communication ports and remote controls
Reviews