Q-switched ND yag laser machine VA-400

$0.00

Shipped From Abroad

The VA-400 Q-Switched Nd:YAG Laser Machine is a high-performance laser system designed for tattoo removal, pigmentation treatment, melasma, dark lips, birthmark and skin rejuvenation. It utilizes dual-wavelength technology (1064nm & 532nm) to effectively break down tattoo ink, melanin, and other pigmentation without damaging surrounding skin.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130182-4
Brands:: Viva-Laser

Description

 

What is a Q switched Nd YAG laser machine?

Nd: YAG laser is applied to kinds of pigmentation treatments. and could achieve obvious lightening of pigmented lesions and ink tattoos. Nd: YAG is short for Neodymium-doped Yttrium Aluminum Garnet. ND Yag laser use crystal rods to produce laser energy.

The light motivates by Nd: YAG laser travel at a wavelength of 1064/532 nm. The laser directly destroys the melanin or pigment in the target area. Yag laser has great results om birthmarks, moles, hyperpigmentation

How does the Q-Switched ND YAG Laser machine Works?

The 1064nm ND YAG Q-Switched laser targets specific melanin or pigmentation in the skin. The pigment absorbs the 1064nm or 532nm laser and destroyed in very tiny particles. The pigment particles or ink tattoo is then absorbed into the bloodstream and eventually expelled from the body.

The Q-Switched ND YAG laser has 3 wavelengths. 1064 nanometers for black and blue color. 532 nanometers, 1064nm is for the deeper layer. While 532nm is fort hyperpigmentation and more superficial layers. 1320nm is utilized for carbon laser facial treatment.

Features
  • High Peak Energy Pulses: Delivers short, intense bursts of laser energy to shatter pigment particles.

  • Versatile Wavelengths: 1064nm targets dark inks (black, blue), while 532nm is ideal for red and orange pigments.

  • Minimal Downtime: Quick recovery with little to no side effects.

  • Smart Cooling System: Ensures safe and comfortable treatments.

  • Touchscreen Interface: User-friendly control for precision treatments.

Applications:
  1. ink tattoos removal
  2. pigmented removal (brown spots, age spots, etc.)
  3. Laser carbon facial
  4. non-ablative skin rejuvenation
Advantages

3 standard laser tips for different treatment.

The nd yag laser machine offers 3 treatment tips.1064nm, 532nm and 1320nm.

  • 1064nm wavelength is for black and blue pigmentation removal
  • 532nm wavelength is for red and brown pigmentation removal
  • 1320nm wavelength is for carbon laser facial treatment

Maximum 10Hz frequency high speed treatment

The q-switched nd yag laser machine frequency is 1 to 10Hz adjustable. High frequency energy output ensures fast tattoo and pigmentation removal treatment.

Large spot size 1-10mm

The spot size for the q-switched YAG laser machine is 1-10mm adjustable. Research has proven that larger spot diameters increase the depth of penetration of the laser into the skin. Larger spot size has obvious results for deeper ink tattoos and pigmentations removal.

Specifications
Laser Type Q-switched ND: YAG Laser
Cooling system Water cooling & Air cooling
Spot Size Φ1-10mm (continuously adjustable)
Energy 0MJ–1000MJ/2000MJ
Power Supply AC 220V 50Hz / AC 10A, 110V 60Hz 10A
Aim Beam Semiconductor 650nm Red Aiming Beam
Wavelength 1064nm, 532nm,1320nm
Pulse Width ≤8ns
Repetition Rate 1-10Hz (adjustable)
Input Power 800W
Xenon lamp Φ7*70*150
Crystal Rods Φ7
Weight 18KG
Dimension 39*44*32
Optional Part Cart, Adjustable Focal Length Stents

Reviews

There are no reviews yet.

Be the first to review “Q-switched ND yag laser machine VA-400”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsQ-switched ND yag laser machine VA-400 removeZerone Liposuction Machine ULTRA-Z & ZP-1000 removeCryoIQ Pro with LED Light for 16 Gram Gas, & Gas cartridge 25 Gram No2 with Valve removeIntense Pulsed Light Therapy Device M80e+ removeIlluco IDS-1000 Dermatoscope Plus removeElectric Dermatome remove
NameQ-switched ND yag laser machine VA-400 removeZerone Liposuction Machine ULTRA-Z & ZP-1000 removeCryoIQ Pro with LED Light for 16 Gram Gas, & Gas cartridge 25 Gram No2 with Valve removeIntense Pulsed Light Therapy Device M80e+ removeIlluco IDS-1000 Dermatoscope Plus removeElectric Dermatome remove
ImageCryoIQ ProIDS-1000 Dermatoscope Plus
SKUSF1033560130182-4SF1033560094SF1033560096-6SF1033560130100-6SF1033560111-2SF10335601214
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$6,507.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The VA-400 Q-Switched Nd:YAG Laser Machine is a high-performance laser system designed for tattoo removal, pigmentation treatment, melasma, dark lips, birthmark and skin rejuvenation. It utilizes dual-wavelength technology (1064nm & 532nm) to effectively break down tattoo ink, melanin, and other pigmentation without damaging surrounding skin.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
LTRA-Z is designed to optimize every stage of the body and face sculpting operation and emulsifies unwanted fatty tissues yet still protects other tissues.
Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad CryoIQ® PRO Contact is based on our contact freezing system (closed gold plated metal contact tips with diameters of 1, 3, 5, or 7 mm). It provides precise treatment of the affected skin areas only in the size of the contact applicator without damage to the surrounding healthy tissue.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Scope of application: Suitable for the treatment of telangiectasia and superficial pigmentation; Improvement of photoaged skin.  
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad
  • Small enough for your pocket or hand bag
  • Light enough to wear it around your neck and carry the whole day
  • Perfect for laypeople who want personally observe their skin changes
  • Reasonably priced
Delivery & Availability: Typically 7-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.    
Shipped From Abroad
1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness adjusting button is unilateral adjustment, with high stability and no need calibrate to zero. 2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm.   Note: Special size width plate can be customized according to requirements. 3. The blade has self-lubricating function and is easy to load and unload. It can move back and forth smoothly to prevent metal to metal collision. 4. Original imported motor, low inertia electric motor will hardly produce any vibration when rotating, rotate speed: 4500-5000rpm. 5. Hand held control, easy to operate; handle with contact switch design, safety to use Delivery & Availability: Typically 14-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Contenthttps://youtu.be/FutuN-nsTss  
What is a Q switched Nd YAG laser machine?
Nd: YAG laser is applied to kinds of pigmentation treatments. and could achieve obvious lightening of pigmented lesions and ink tattoos. Nd: YAG is short for Neodymium-doped Yttrium Aluminum Garnet. ND Yag laser use crystal rods to produce laser energy. The light motivates by Nd: YAG laser travel at a wavelength of 1064/532 nm. The laser directly destroys the melanin or pigment in the target area. Yag laser has great results om birthmarks, moles, hyperpigmentation
How does the Q-Switched ND YAG Laser machine Works?
The 1064nm ND YAG Q-Switched laser targets specific melanin or pigmentation in the skin. The pigment absorbs the 1064nm or 532nm laser and destroyed in very tiny particles. The pigment particles or ink tattoo is then absorbed into the bloodstream and eventually expelled from the body. The Q-Switched ND YAG laser has 3 wavelengths. 1064 nanometers for black and blue color. 532 nanometers, 1064nm is for the deeper layer. While 532nm is fort hyperpigmentation and more superficial layers. 1320nm is utilized for carbon laser facial treatment.
Features
  • High Peak Energy Pulses: Delivers short, intense bursts of laser energy to shatter pigment particles.

  • Versatile Wavelengths: 1064nm targets dark inks (black, blue), while 532nm is ideal for red and orange pigments.

  • Minimal Downtime: Quick recovery with little to no side effects.

  • Smart Cooling System: Ensures safe and comfortable treatments.

  • Touchscreen Interface: User-friendly control for precision treatments.

Applications:
  1. ink tattoos removal
  2. pigmented removal (brown spots, age spots, etc.)
  3. Laser carbon facial
  4. non-ablative skin rejuvenation
Advantages
3 standard laser tips for different treatment. The nd yag laser machine offers 3 treatment tips.1064nm, 532nm and 1320nm.
  • 1064nm wavelength is for black and blue pigmentation removal
  • 532nm wavelength is for red and brown pigmentation removal
  • 1320nm wavelength is for carbon laser facial treatment
Maximum 10Hz frequency high speed treatment The q-switched nd yag laser machine frequency is 1 to 10Hz adjustable. High frequency energy output ensures fast tattoo and pigmentation removal treatment. Large spot size 1-10mm The spot size for the q-switched YAG laser machine is 1-10mm adjustable. Research has proven that larger spot diameters increase the depth of penetration of the laser into the skin. Larger spot size has obvious results for deeper ink tattoos and pigmentations removal.
Specifications
Laser Type Q-switched ND: YAG Laser
Cooling system Water cooling & Air cooling
Spot Size Φ1-10mm (continuously adjustable)
Energy 0MJ–1000MJ/2000MJ
Power Supply AC 220V 50Hz / AC 10A, 110V 60Hz 10A
Aim Beam Semiconductor 650nm Red Aiming Beam
Wavelength 1064nm, 532nm,1320nm
Pulse Width ≤8ns
Repetition Rate 1-10Hz (adjustable)
Input Power 800W
Xenon lamp Φ7*70*150
Crystal Rods Φ7
Weight 18KG
Dimension 39*44*32
Optional Part Cart, Adjustable Focal Length Stents
LTRA-Z is designed to optimize every stage of the body and face sculpting operation and emulsifies unwanted fatty tissues yet still protects other tissues. Quick recovery of patient thanks to minimize invasive procedure. Proper probes with various diameters to treat all areas of the body - Various ranges of diameters, 1.2mm to 3.7mm, provide tailor-made liposculpture for small volumes of fatty tissues in complicated areas and quick removing large volumes of fatty tissues. Technical Specification: Ultrasonic Surgical Unit 90W, AC110V or AC230V,50/60Hz, Class 1, Type BF, Ultrasonic Lipolysis Suction-Irrigation Pumps 1) Irrigation pump Flow rate: max. 1375mL/min, Class 1, Type BF, AC220V/50Hz2) Suction Pump Oilless piston vacuum pump, 100L/min, 680mmHg,
AC220V/60Hz
 
Click Here To Download Catalogue
CryoIQ® PRO Contact is based on our contact freezing system (closed gold plated metal contact tips with diameters of 1, 3, 5, or 7 mm). It provides precise treatment of the affected skin areas only in the size of the contact applicator without damage to the surrounding healthy tissue. The most versatile model for contact freezing treatment of warts and common skin lesions. Its unique construction with a built-in non-return valve prevents gas leakage, thus giving maximum use of the gas content. With the new PRO model, you now have the possibility to change the tip for different areas of application, such as dermatology, dentistry, podiatry, gynecology/urology, and veterinary. Features:
  • Simple pencil type grip for easy use and accurate application
  • A broad range of applicators
  • Freezing temperature
    • Liquid freezing, -89°C / -128°C
    • Contact freezing, -80°C / -112°C
  • The level of cold generated is adjusted by the rate at which the metering lever is depressed
  • CE marked according to Medical Device II
Technical Specifications:
Name: CryoIQ® PRO Contact
Order.no: CIQ-P-C
Delivered in: Plastic case
Included in delivery: 1 gas cartridge (16 gram) with valve
Weight: 82 gram (including 16-gram cartridge)
Dimensions: Diameter: 22 mm / Length: 130 mm
Freezing temperature: “Liquid freezing”, -89 °C / -128 °F
“Contact freezing”, -80 °C / -112 °F
Contact surface for CIQ-P-C: Diameter: 1, 3 or 5 mm
Material: Gold plated metal
Patented: Yes
CE marked: According to medical device IIA
Warranty: 1 year (2 years after Product registration)
Gas cartridge: 16 or 25 gram
Nitrous Oxide Gas (N2O)
Medical sterile
Built-in filter (5 µm)
 
Operating range:
Suitable for operations on telangiectasia and superficial pigmentation: improvement of photoaged skin.

Technical Parameters:

Gear model: F+E Rated input power (w): 1300 Dimensions (mm): 520*430*1040 Weight (Kg): 45

Accessories Details:

The equipment consists of operating tools and filters, power supply and control device, protection system, cooling system (internal circulation water cooling, fan).
Illuco IDS-1000 plus compact and Light:
  • Small enough for your pocket or handbag
  • Light enough to wear it around your neck and carry the whole day
  • Perfect for laypeople who want personally observe their skin changes
  • Reasonably priced
Dermoscopy requires a high-quality magnifying lens and likewise high-quality light sources that can help you with examining skin structures and patterns. IDS-1000 was also developed by ILLUCO optical experts and therefore we guarantee its excellent optical & light performances:
  • 10 x magnification
  • Contact & non-contact dermoscopy with polarized light
  • Contact & non-contact dermoscopy with non-polarized light
  • Smartphone & camera compatibility (IDS-1000 Plus only)
N/B: Polarized to non-polarized (or reverse) mode is manually to change by turning the cone hood (light mode change dial).
  • Polarization mode: 3 o'clock
  • Non-polarization mode: 12 o'clock
Differently from the Illuco IDS-1000 dermatoscope, contact plates for the IDS-1000 series are bonded to the cone hood. There are three different types of cone hood:
  • Open top (with no contact plate)
  • With contact plate (no scale)
  • With scale contact plate
Smartphone and Camera Compatibility: The only difference between "IDS-1000" and "IDS-1000Plus" is the smartphone and camera compatibility. Dermatoscope IDS-1000Plus offers smartphone,  mirrorless & compact camera compatibility. Use a smartphone to observe and photograph common skin lesions that are not complicated or difficult. If you need more detailed observations, use a camera to obtain dedicate and precise images. Note: the compatible mirrorless cameras are of Canon, Sony and Nikon. Technical Specifications: 
Technical Specification IDS-1000 IDS-1000Plus
Polarization Cross & Parallel Cross & Parallel
Field of view 18 mm 18 mm
Magnification 10 x 10 x
Depth of field 1.5 1.5
Resolutuion 95 LP 95 LP
LED 8 White LEDs 8 White LEDs
Focus mode Fixed Fixed
Battery Disposable Lithium 6V 2CR5 Disposable Lithium 6V 2CR5
Continuous duty time 8 hours 8 hours
Camera & smartphone compatibility No Yes
Contact & Non-contact examination Yes Yes
Net dimension / weight 51 x 112 x 23 (mm) / 100g 51 x 112 x 23 (mm) / 110g
Package dimension / weight 70 x 170 x 60 (mm) / 330g 70 x 170 x 60 (mm) / 330g
 
Click Here To Download Catalogue
Electric Dermatome
Technical Parameters: 1. Skin Graft Thickness: 0-0.75 mm in 0.05 mm increment, the skin thickness adjusting button is unilateral adjustment, with high stability and no need calibrate to zero. 2. Skin Graft Width: 2.5~10.2cm,4 size width plates:2.5cm,5.1cm,7.6cm,10.2cm.   Note: Special size width plate can be customized according to requirements. 3. The blade has self-lubricating function and is easy to load and unload. It can move back and forth smoothly to prevent metal to metal collision. 4. Original imported motor, low inertia electric motor will hardly produce any vibration when rotating, rotate speed: 4500-5000rpm. 5. Hand held control, easy to operate; handle with contact switch design, safety to use. 6. Exclusive design of pulled and plugged handle connection line, easy to use. (the length of handle connection line is greater than 3m) 7. Power supply: 220V±10% AC automatic switching, 150/60Hz single phase. Output 14.5V DC, 4.3A. 8. Degree of prevention of liquid entry: IPXO. 9. Sterilization Method: Sterilization Mode: pre-vacuum and gravity displacement steam sterilization or low temperature plasma sterilization can be conducted in whole machine and power cord. And the power cord can be pulled and plugged.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare