New

Schiötz Tonometer

$0.00

Shipped From Abroad

The Schiötz Tonometer is a highly precise instrument used to measure intraocular pressure (IOP) for the diagnosis and prevention of glaucoma. It features a reliable agate bearing for long service life and an easy-to-read scale, supplied complete with three calibration weights.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Riester

Description

Indispensable in ophthalmology, the Riester Schiötz Tonometer provides precise IOP measurement using the indentation method. The instrument is engineered with a high-quality agate bearing to ensure longevity and accuracy. It comes complete in a black deluxe case with velvet-look inserts, including three standard weights (5.5 g, 7.5 g, 10 g) and a conversion table for quick interpretation of the readings.

Features and benefits
  • High-quality agate bearing for an extremely long service life
  • Precision measurement on a scale of 0 to 20 subdivisions and 0 to -1 subdivisions
  • Easy-to-read scale with red pointer
  • Complete in a black deluxe case with velvet-look inserts
  • Supplied with three weights (5.5 g, 7.5 g, 10 g) and a conversion table
Product details
Schiötz Tonometer
Dimensions Height: 130 mm, Width: 45 mm, Weight: 24.4 g
Scale 0 to 20 graduation marks
0 to -1 graduation mark
One graduation mark corresponds to a stroke of 0.05 mm
Operating temperature 10 °C to 40 °C
Relative humidity 30% up to 70 % relative humidity, non-condensing
Storage temperature -20 °C to 70 °C
Storage relative humidity up to 85 % relative humidity, non-condensing
Air pressure 700 hPa – 1060 hPa

 

Download Catalogue

Reviews

There are no reviews yet.

Be the first to review “Schiötz Tonometer”

Your email address will not be published. Required fields are marked *

Quick Comparison

Schiötz Tonometer removeSW-1000 Ophthalmic Ultrasound Scanner-A-Scan removeOperation Microscope removeApplanation Tonometer removeBinocular Indirect Ophthalmoscope removePortable Keratometer remove
NameSchiötz Tonometer removeSW-1000 Ophthalmic Ultrasound Scanner-A-Scan removeOperation Microscope removeApplanation Tonometer removeBinocular Indirect Ophthalmoscope removePortable Keratometer remove
ImageMecan SW-1000 Ophthalmic Ultrasound Scanner-A-ScanMecan YZ20P5 Operation MicroscopeMecan Applanation Tonometer YZ30XMecan YZ25C Binocular Indirect OphthalmoscopeMecan SW 100 Portable Keratometer
SKUSF1033560107-27SF1033560107-24SF1033560107-1SF1033560107-4SF1033560107-16
Rating
Price

$0.00

$1,815.00

$2,695.00

$0.00

$880.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The Schiötz Tonometer is a highly precise instrument used to measure intraocular pressure (IOP) for the diagnosis and prevention of glaucoma. It features a reliable agate bearing for long service life and an easy-to-read scale, supplied complete with three calibration weights.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad
  • Large color liquid-crystal screen
  • Touch screen input, easy operation
  • Curve freezing: Manual/Auto mode, controlled by pedal
  • Built-in speed thermal printer
  • Enter the name & ID; easy to check archive
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad YZ20P5 Operation Microscope is a simple binocular coaxial microscope for a single man. The Operation  Microscope is small, light, and convenient. It has high agility and can meet the requirements for general ophthalmology operation. The microscope fits mobile medical treatment.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad Super lightweight design, reduce fatigue, operation is very convenient.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
ContentIndispensable in ophthalmology, the Riester Schiötz Tonometer provides precise IOP measurement using the indentation method. The instrument is engineered with a high-quality agate bearing to ensure longevity and accuracy. It comes complete in a black deluxe case with velvet-look inserts, including three standard weights (5.5 g, 7.5 g, 10 g) and a conversion table for quick interpretation of the readings.
Features and benefits
  • High-quality agate bearing for an extremely long service life
  • Precision measurement on a scale of 0 to 20 subdivisions and 0 to -1 subdivisions
  • Easy-to-read scale with red pointer
  • Complete in a black deluxe case with velvet-look inserts
  • Supplied with three weights (5.5 g, 7.5 g, 10 g) and a conversion table
Product details
Schiötz Tonometer
Dimensions Height: 130 mm, Width: 45 mm, Weight: 24.4 g
Scale 0 to 20 graduation marks 0 to -1 graduation mark One graduation mark corresponds to a stroke of 0.05 mm
Operating temperature 10 °C to 40 °C
Relative humidity 30% up to 70 % relative humidity, non-condensing
Storage temperature -20 °C to 70 °C
Storage relative humidity up to 85 % relative humidity, non-condensing
Air pressure 700 hPa - 1060 hPa
  Download Catalogue
Feature:
  • Large color liquid-crystal screen
  • Touch screen input, easy operation
  • Curve freezing: Manual/Auto mode, controlled by a pedal
  • Built-in speed thermal printer
  • Enter the name & ID; easy to check the archive
Technical Specifications:
Model SW-1000 Ophthalmic A Scan Biometer
A Scan
A scan probe 10MHz import small size probe, built-in luminotron
Measuring range 15mm-40mm
Measurement precision ±0. 05mm; with macula lutea trace function
Measurement Anterior chamber depth, lens thickness, vitreous body length, total length and average
Method of measurement immersion and contact
Eye mode Phakic/ Aphakic/Dense/ various IOL
IOL formula SRK-II, SRK-T, BINKHORST- Ⅱ, HOLLADAY, HOFFER-Q, HAIGIS
Storage 10 cases, 5 readings each case
Output

A scan waveform and IOL calculation sheet

Operation Microscope(YZ20P5) is a simple binocular coaxial microscope for a single man. The Microscope is small, light, and convenient. It has high agility and can meet the requirements for general ophthalmology operation. The microscope fits mobile medical treatment. Features of Operation Microscope:
  • Multi-layer coating technology is used on optical lenses to enhance the transmission rate and prevent mildew.
  • Foot-controlled focus, three-step magnification change, good depth of field of view, and good binocular fusion to meet the need of cataract surgery.
  • Using apochromatic technology to make different wavelengths of the light focus near the focal point behind the lens, so as to make the operator's vision more clearly.
  • The machine weighs only 41Kg to be light and compact and is especially applicable for mobile medical.
  • Optional desktop components to make the machine more portable and can also be customized according to special requirements to meet the needs in ophthalmology, ENT and other surgery.
  • Optional F250/F300/F400 lens.
Technical Specifications of Operation Microscope:

Eyepiece Magnification

12.5×

Focal Length of Objective Lens

F=200

Working Distance

190 mm

Magnification for Main Microscope

5.3×, 8×, 16×

Diameter of Field

37 mm, 25 mm, 16.7 mm

Diopter Adjustment

±5D

Pupillary Distance

50 mm ~ 70 mm

Maximum Resolution

100 LP/mm

Light Source

12V/100W halogen lamp for medical use

Illumination Type

 6° coaxial illumination of the cold light source

Coaxial Illuminance

≥30,000 Lx

Reaching Radius of Arm

870 mm

Adjustable Vertical Range

700 mm~1100 mm

Fine Focusing Range 30 mm

Input Voltage

AC 220V/110V±10%, 50Hz/60Hz

Power Consumption

120 VA

Fuse

AC 250V   T4.0A, AC 125V  T8.0A

Electrical Safety Standard

IEC 60601-1, Class I

Packing Volume 

0.2 m3,1 carton

Total Weight 

41 kg

 
Click Here To Download Catalogue 
Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type). Features of Applanation Tonometer:
  • When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
  • Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
  • Directly get the ocular pressure and do not need to look up the conversion table.
  • The measured ocular pressure is not affected by hardness of eye.
  • The affected?ocular volume is just 0.56 cubic millimeter.
  • Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
  • Measuring Range: 0~1064 Kpa
  • Light Ring Displacement: 1.53×2=3.06mm
  • Diameter of Prism Head: 7mm
  • Moving Range of Prism Head: 3mm
Ophthalmoscope Features:
  • LED bulb(low-temperature,low-pressure,high-brightness) with long lifetime to make the illumination uniformly and bright. The illumination brightness can be adjusted continuously.
  • Imaging clearly,strong dimensional sense and large field of view range.The main body part of this device adopts engineering plastics and is designed to be compact and exquisite.
  • Super lightweight design, reduce fatigue,operation is very convenient.
  • The portable power supply is suitable for surgery, ward round and consultation.
  • This device is equipped with color filter,teaching mirror and sclera depressor to be more handy in operation.
Technical Specifications:
Pupilary Adjustment 52mm~74mm adjustable
Intensity of Illumination continuous adjustment with the maximum intensity no less than 500Lx
Headband 520~640mm in circumference, 85~125mm in depth
Light Spots Big spot, middle spot  and small spot
Filters Red-free, white and cobalt blue
Light Source LED light
Source of Power Li+ battery, DC 7.4V
AC 100~240V, 50/60Hz
Input Power Battery charger: 15 VA
AC charger: 50VA
Dimension of Main Part 142mm × 48mm × 128mm(long×breadth×high)
Weight of Main Part 230g
Portable Keratometer Features: Ultra-small corneal curvature tester, is mainly used to measure the corneal curvature radius and diopter, wireless output print data. Technical Specifications:
Model SW-100
Measuring Range 6.5mm~9.5mm: ±0.05mm: 0.01mm
Precision ± 0.05mm
Resolution of Curvature Radius of Cornea 0.01mm
Single Measuring Time 0.03s
Output Wireless Infrared Thermal Printer
Can observe the eye directly through the screen.
Weight 0.5Kg(with batteries)
Dimension 240mmx90mmx60mm
Power 500mW+15%
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar