Description | Shipped From Abroad
The M-240 microtome from Myr uses state-of-the-art technology and embodies the our commitment to quality and excellence in the microtomy. It provides the operational convenience and the stability required for outstanding sectioning in routine, research and industry applications.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
Advanced routine laboratory microscope for brightfield observations with IOS W-PLAN objectives and rackless stage. The high-efficiency X-LED3 makes it reliable for all transmitted light observations for great-looking, rich and high-quality view.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped From Abroad
The fully automated Leica RM2255 microtome embodies the latest technological innovations in microtomy and perfectly harmonizes practical features with an ergonomic design and user safety. Its two-in-one design concept, which allows motorized as well as manual sectioning, provides reproducible, quality sections.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | Shipped from Abroad
Phase contrast, darkfield and brightfield binocular microscope with W-PLAN objectives, rackless stage and combining the exclusive X-LED3 with ALC (Automatic Light Control) for great-looking, rich and highquality view.
Delivery & Availability:
Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock
Needle destruction destroy the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Delivery & Availability:
Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | Features
Full color TFT 7” display with PCAD (projected capacitive) touchscreen. Size and tilt of the display allow an easy and effortless selection of the parameters and increase user safety.
All required parameters and functions are available on the main screen: section mode, section and trimming thickness, section counter, section sum, remaining travel, retraction and coarse feed, memory function.
MEM key for higher productivity, to retrieve previous cuttings settings when working with uniform paraffin blocks. By simply pressing a key, the specimen moves into the stored MEM position.
Thanks to a blocking mechanism the easy to operate change system allows to work with different specimen clamps. Indication of 0-position in x and y direction by palpable “click” for the precise alignment of the specimen.
Precise, motorized coarse feed in two modes, continuous and step. In continuous mode, speed is selectable between slow and fast to ensure a controlled specimen approach.
- Quick release specimen clamp
Cutting-edge design of the specimen clamp that prevents building up of dirt and facilitates operations with the microtome. The retraction function selectable between 5 -250μ can be deactivated, although it is advisable as it prolongs the life of the blade. ( Default value 40 μ)
Special antistatic coating prevents paraffin adhesion and minimizes the cleaning time. Ergonomic design with surface for arm rest. Wide area on the top of the microtome for the storage of tools.
Blade holder slides sideways in both directions allowing the use of the entire cutting edge. It accepts low- and high-profile blades. All blade holders are equipped with finger guard for safety reasons.
- Smooth and ergonomic handwheel
The handwheel is perfectly balanced thanks to an innovating counterweight system and can be locked in any angular position. Cutting can be done by turning the handwheel clockwise or counterclockwise.
Technical Data Microtome M-240
Section thickness |
|
Total range in (μm) |
0,5 – 100 |
Thickness settings in (μm) |
|
|
0,5 – 5 in increments of 0,5 |
|
5 – 20 in increments of 1 |
|
20 – 60 in increments of 5 |
|
60 – 100 in increments of 10 |
Trimming |
|
Total range in (μm) |
1 – 600 |
Thickness settings in (μm) |
|
|
1 – 10 in increments of 1 |
|
10 – 20 in increments of 2 |
|
20 – 50 in increments of 5 |
|
50 – 100 in increments of 10 |
|
100 – 600 in increments of 50 |
Specimen feed (mm) |
28 ± 1 mm |
Vertical stroke (mm) |
72 ± 1 mm to allow sectioning of mega-cassettes |
User interface |
7” capacitive touchscreen display |
Operating modes |
Rotational or Rocking (selectable) |
Specimen retraction |
Optional function that can be deactivated |
Total range in (μm) |
5 – 250 μm (selectable in 1 μm increment) |
|
5 predefined values: 20, 30, 40, 60, 80 μm |
|
Default value: 40 μm |
Motorized coarse feed (μm/sec) |
|
|
300 (slow speed forward) |
|
800 (fast speed forward) |
|
1800 (ultrafast speed backward) |
|
Additional function for forward/backward coarse feed in step mode |
Blade Holder Type |
Two in One for high- and low-profile blades |
Max. specimen size |
50x60x40 mm (w x h x d)
Super cassette clamp 68x48x15 mm |
Specimen orientation |
|
|
± 8º horizontal and vertical |
|
Rotational capability: 360º |
|
Indication of 0-position by means of click (x and y direction) |
Power requirements |
100-240 VAC / 50-60Hz |
Consumption |
40 VA |
Dimensions |
|
Width |
465 mm |
Depth with tray |
540 mm |
Height |
298 mm |
Weight |
33,9 kg |
| Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety.
Features:
- Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
- Max. speed: 14,100 x g (14,500 rpm)
- Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
- Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
- Rotor can be autoclaved at 121°C for 20 minutes
- Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
- Eliminate costly repairs with the low maintenance drive
- Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: |
800 – 13,400 rpm (100 rpm steps) |
Capacity: |
12 x 1.5/2.0 mL |
Electrical: |
120 V, 60 Hz |
Dimensions: |
(W x D x H) 22.6 x 23.9 x 12.0 cm |
Weight: |
4.3 kg |
| Advanced routine laboratory microscope for brightfield observations with IOS W-PLAN objectives and rackless stage. The high-efficiency X-LED3 makes it reliable for all transmitted light observations for great-looking, rich and high-quality view.
Features:
- Observation mode: Brightfield.
- Head: Trinocular (fixed 50/50), 30° inclined, 360° rotating.
- Interpupillary distance: Adjustable between 50 and 75 mm.
- Dioptric adjustment: On the left eyepiece tube.
- Eyepieces: WF10x/22 mm, high eye-point and with rubber cups.
- Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
- Objectives:
– IOS W-PLAN 4x/0.10
– IOS W-PLAN 10x/0.25
– IOS W-PLAN 40x/0.65
– IOS W-PLAN 100x/1.25 (Oil)
All with anti-fungus treatment.
- Specimen stage: Double layer rackless mechanical stage, 233×147 mm, 78×54 mm X-Y range.
- Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
- Condenser: Swing-out N.A. 0.2/0.9, with iris diaphragm, focusable and centerable.
- Transmitted illumination (Full Koehler type): X-LED³ with white 3.6 W LED (6,300K) with brightness control. Multi-plug 100-240Vac/6Vdc external power supply.
Technical Specifications:
Observation Method -
Transmitted Light |
Brightfield |
Yes |
|
Phase contrast (Positive type) |
As optional |
|
Darkfield |
As optional |
|
Simple polarized light |
As optional |
Main Body |
Type |
Upright |
|
Construction material |
Aluminum die-cast |
|
Trasportation handle |
Yes |
Head |
Type |
Trinocular (Siedentopf) |
|
Split ratio |
50/50 |
|
Inclination |
30° |
|
360° rotating |
Yes |
|
Interpupillary distance (mm) |
50-75 |
|
Dioptric adjustement |
On left tube |
|
Tube inner diameter (mm) |
30 |
Eyepieces |
Field number (mm) |
22 |
|
Magnification |
10x |
|
Planar type |
Yes |
|
Micrometric scale |
As optional |
|
Diameter of micrometer glass (mm) |
26 |
|
High eyepoint (for glass wearers) |
Yes |
|
Rubber cup |
Yes |
|
Retractable protections |
Yes |
Nosepiece |
Positions |
Quintuple |
|
Reversed |
Yes |
|
Bi-directional |
Yes |
|
Rotation on ball bearings |
Yes |
|
Objective thread |
RMS |
Objectives |
Optical system |
∞ |
|
Anti-fungus treatment |
Yes |
|
Parfocal distance (mm) |
45 |
|
Standard magnifications |
40x-1000x |
|
Type |
IOS W-PLAN |
|
Objectives included |
4x/0.10, W.D. 17.3 mm
10x/0.25, W.D. 10 mm
40x/0.65, W.D. 0.54 mm
100x/1.25 (Oil),
W.D. 0.13 mm |
Stage |
Type |
Double layer |
|
Dimensions (mm) |
233x147 |
|
Moving mechanism |
Rackless |
|
Moving range (mm) |
78x54 |
|
Material |
Anti-scratch painting |
|
Specimen holder |
Yes |
|
Slide number |
2 |
|
Click-stop (45°) |
No |
|
X-Y Vernier scale |
Yes |
|
Vernier scale accuracy (mm) |
0.1 |
Condenser - Single
Position |
Type |
Swing-out |
|
Removable |
Yes |
|
Numerical aperture (N.A.) |
0.2 / 0.9 |
|
Diaphragms |
Iris |
|
Centrable |
Yes |
|
Focusable |
By rack and pinion |
Focusing System |
Type |
Coaxial coarse & fine |
|
Coarse total travel (mm) |
25 |
|
Fine total travel (per single rotation) (mm) |
0.2 |
|
Fine graduations |
100 |
|
Fine resolution (µm) |
2 |
|
Upper stop to prevent contact |
Yes |
|
Adjustable tension |
Yes |
|
Flat knob for ergonomy |
Yes |
Transmitted
Illumination |
Kohler illumination |
Full |
|
Type |
X-LED |
|
X-LED type |
X-LED3 |
|
Light source power (W) |
3.6 |
|
Brightness control |
Manual
|
|
Lifetime (hours) |
> 65,000 |
|
Temperature (K) |
6,300 |
|
Max. required power (W) |
6 |
Power Supply for
Transmitted
Illumination |
Type |
External |
|
Microscope connector |
Jack, 2.1 mm |
|
Power plug type |
Multi-plug (EU, UK, US) |
|
Input voltage |
100/240 Vac, 50/60 Hz |
|
Output voltage |
6 Vdc 2.5A |
Accessories Included |
Dust cover |
Yes |
|
Immersion oil (10ml) |
Yes |
|
Tension adjustment tool |
Yes |
|
Allen wrench |
Yes |
|
User Manual |
Digital version (downloadable) |
Additional Information |
|
Heating stage (as optional).
External rechargeable battery pack (as optional). |
Product Weight |
Height (mm) |
420 |
|
Width (mm) |
270 |
|
Depth (mm) |
390 |
Product Weight |
(kg) |
9 |
| The fully automated Leica RM2255 microtome embodies the latest technological innovations in microtomy and perfectly harmonizes practical features with an ergonomic design and user safety. Its two-in-one design concept, which allows motorized as well as manual sectioning, provides reproducible, quality sections.
Features:
- Compact, ergonomic design
- Ergonomically designed handwheel handle
- Smooth-running handwheel with integrated quick-lock mechanism for safety
- Enclosed micrometer feed mechanism
- Low-maintenance cross-roller bearings
- Two forward and backward coarse feed speeds
- Alternate trimming and sectioning modes, as indicated on the display
- Speed control through the cutting window for enhanced efficiency
- Automatic, variable specimen retraction, depending on sectioning speed
- Section thickness totalizer and section counter
- Intuitive control panel
- Integrated communication display
- Precise specimen orientation with zero point reference
- Knife holder design with red colored knife guard
- Precise lateral knife holder adjustment with click stop settings
- Spacious and easy-to-clean section waste tray
- Wide range of accessories
Technical Specifications:
Section thickness
Setting thickness setting range: 0.5 – 100 µm
Setting values: from 0.5 – 5 µm in 0.5 µm increments
from 5 – 20 µm in 1 µm increments
from 20 – 60 µm in 5 µm increments
from 60 – 100 µm in 10 µm increments
Trimming section thickness setting range: 1 – 600 µm
Setting values: from 1 – 10 µm in 1 µm increments
from 10 – 20 µm in 2 µm increments
from 20 – 50 µm in 5 µm increments
from 50 – 100 µm in 10 µm increments
from 100 – 600 µm in 50 µm increments
Object feed: 24 mm ± 1 mm, feed motion via step motor
Vertical specimen stroke: 70 mm
Sectioning modes: 4
Specimen retraction:
In manual operation: 5 – 100 µm in 5 µm increments, can be turned off
In motorized operation: varying with the sectioning speed, can be turned of
Electric coarse feed: 300 µm/s and 800 µm/s
Sectioning speed: 0.5 – 420 mm/s ± 10%
Maximum specimen size (L x H x W): 50 x 60 x 40 mm
Specimen orientation horizontal: ±8°, vertical: ±8°
Nominal supply voltages: 100/120/230/240 V AC ± 10%
Nominal frequency: 50/60 Hz
Power draw: 340 VA
Dimensions basic instrument
Width (incl. handwheel): 413 mm
Depth (incl. waste tray): 618 mm
Height (with storage area on cover): 305 mm
Weight (without accessories): Approx. 40 kg
Dimensions control panel: W x D x H 121 x 166 x 50 mm
Weight: approx. 0.66 kg, approx. 1.45 Ibs
Click Here To Download Catalogue | Phase contrast, darkfield and brightfield binocular microscope with W-PLAN objectives, rackless stage and combining the exclusive X-LED3 with ALC (Automatic Light Control) for great-looking, rich and highquality view.
Features:
- Observation mode: Brightfield, phase contrast and darkfield (dry).
- Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged).
- Interpupillary distance: Adjustable between 48 and 75 mm.
- Dioptric adjustment: On the left eyepiece tube.
- Eyepieces: WF10x/20 mm, high eye-point and secured by screw.
- Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings.
- Objectives:
W-PLAN 4x/0.10
W-PLAN PH 10x/0.25
W-PLAN PH 40x/0.65
W-PLAN PH 100x/1.25 (Oil/Water)
All with anti-fungus treatment.
- Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range.
- Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen.
- Condenser: Phase condenser (10x/20x, 40x, 100x) with darkfield (dry) and brightfield.
- Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply
Technical Specifications:
Observation Method -
Transmitted Light |
Brightfield |
Yes |
|
Phase contrast (Positive type) |
Yes |
|
Darkfield |
Yes |
|
Simple polarized light |
As optional |
Main Body |
Type |
Upright |
|
Construction material |
Aluminum die-cast |
|
Trasportation handle |
Yes |
Head |
Type |
Binocular (Siedentopf) |
|
Inclination |
30° |
|
360° rotating |
Yes |
|
Interpupillary distance (mm) |
48-75 |
|
Dioptric adjustement |
On left tube |
|
Fixing screw for eyepieces |
Yes |
|
Tube inner diameter (mm) |
23 |
Eyepieces |
Field number (mm) |
20 |
|
Magnification |
10x |
|
Pointer |
As optional |
|
Micrometric scale |
As optional |
|
Diameter of micrometer glass (mm) |
21 |
|
High eyepoint (for glass wearers) |
Yes |
|
Rubber cup |
Yes |
Nosepiece |
Positions |
Quintuple |
|
Reversed |
Yes |
|
Bi-directional |
Yes |
|
Rotation on ball bearings |
Yes |
|
Objective thread |
RMS |
Objectives |
Optical system |
160 |
|
Anti-fungus treatment |
Yes |
|
Parfocal distance (mm) |
45 |
|
Standard magnifications |
40x-1000x |
|
Type |
IOS |
|
|
W-PLAN
4x/0.10, W.D. 15.8 mm
W-PLAN PH
10x/0.25, W.D. 12.2 mm
W-PLAN PH
40x/0.65, W.D. 0.37 mm
W-PLAN PH
100x/1.25 (Oil),
W.D. 0.13 mm |
Stage |
Type |
Double layer |
|
Dimensions (mm) |
150x139 |
|
Moving mechanism |
Rackless |
|
Moving range (mm) |
75x33 |
|
Material |
Anti-scratch painting |
|
Specimen holder |
Yes |
|
Slide number |
1 |
|
X-Y Vernier scale |
Yes |
|
Vernier scale accuracy (mm) |
0.1 |
Condenser - Multiple
Position |
Type |
Abbe.
Brightfield - Phase contrast - Darkfield (dry) |
|
Number of positions |
5 (BF, 10x/20x, 40x, 100x, DF) |
|
Numerical aperture (N.A.) |
1.25 |
|
Removable |
Yes |
|
Diaphragms |
Iris |
|
Centrable |
Yes |
|
Focusable |
By rack and pinion |
Focusing System |
Type |
Coaxial coarse & fine |
|
Coarse total travel (mm) |
25 |
|
Fine total travel (per single rotation) (mm) |
0.2 |
|
Fine graduations |
100 |
|
Fine resolution (µm) |
2 |
|
Upper stop to prevent contact |
Yes |
|
Adjustable tension |
Yes |
|
Flat knob for ergonomy |
Yes |
Transmitted
Illumination |
Kohler illumination |
Fixed (full as optional) |
|
Type |
X-LED |
|
X-LED type |
X-LED3 |
|
Light source power (W) |
3.6 |
|
Brightness control |
Manual
& Automatic (ALC) |
|
Lifetime (hours) |
> 65,000 |
|
Temperature (K) |
6,300 |
|
Max. required power (W) |
6 |
Power Supply for
Transmitted
Illumination |
Type |
External |
|
Microscope connector |
Jack, 2.1 mm |
|
Power plug type |
Multi-plug (EU, UK, US) |
|
Input voltage |
100/240 Vac, 50/60 Hz |
|
Output voltage |
6 Vdc 2.5A |
Accessories Included |
Dust cover |
Yes |
|
Immersion oil (10ml) |
Yes |
|
Tension adjustment tool |
Yes |
|
Allen wrench |
Yes |
|
Centering telescope |
Yes |
|
Green filter |
Yes |
|
User Manual |
Digital version (downloadable) |
Additional Information |
|
External rechargeable battery pack (as optional) |
Product Weight |
Height (mm) |
405 |
|
Width (mm) |
235 |
|
Depth (mm) |
370 |
Product Weight |
(kg) |
8 |
| Needle destruction destroys the needle immediately following its use. Needle destruction are an absolute necessity in developing parts of the world to prevent the reuse of needles and the spread of bloodborne pathogens. They are NOT a good alternative, however, for hospital use in the developed parts of the world. Needle destruction are products that bend, cut, or destroy the needle. This are distinctly different from needle destroyer that send an arc of electricity to vaporize and melt the needle.
Features:
- Well built
- Easy to maintain
- Having a rubbish drawer with alarm function, this is our most popular model of Syringe Destroyer for use in labs, pharma, universities and doctors clinics
- With its low factory-direct price and excellent quality, its a great addition to add to any medical industry or university office that wants to ensure the safety and legal compliance of its operations
Specifications:
- Short Name: Needle destruction / Needle Destroyer
- Working Noise: ≤50 decibel
- Superheating Sanitization Temperature: 95 deg C
- Working Time: Can completely melt and destroy needle and neck of syringe in 5 seconds
- Working Noise: ≤50 decibel
- Dimensions: Approx. 38cm x 29cm x 28cm
- Power: AC 110V or 220V
|
Reviews
There are no reviews yet.