Sidestream Multigas Module AneSure-S

$0.00

Shipped From Abroad

Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130170-12
Brands:: Kingst

Description

Features of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution

Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.

  • Side Stream Mode

Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.

  • Plug And Play

The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.

  • Automatic Pressure Compensation

There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.

  • High-precision

Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.

 

Specifications of Anesthesia Multi-gas Detector AneSure-S
Working condition 5°C to 50°C, 10 to 90% RH, non-condensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
EtCO2, FiCO2 measurement Range:0-150 mmHg, 0-20 kPa, 0-19.7%

Accuracy:±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

Respiration rate Range: 3-150 BPM

Accuracy: ±1% of reading or ±1 rpm whichever is greater

FiN2O, EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading)

8-12%: unspecified

FiSEV, EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading)

10-15%: unspecified

FiDES, EtDES measurement Range:0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading)

18-25%: unspecified

Gas compensation O2 (HOST supplied), or automatic compensation if O2 equipped
Barometric Pressure Having a barometric pressure sensor and automatic compensation
Warm-up time 10 seconds reach the designed deviation of 97%,

20 seconds reach the designed deviation.

Rise times (t10- 90 %) CO2:<200ms

N2O, AGENT: <300ms

Flow control Range: 50-250ml/min adjustable

Accuracy: <±20%

Calibration No need to calibrate
Zero Implement when the gas value’s offset is observed, or when any unspecified accuracy message is displayed

 

Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution. Equipped with Oxygen battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side stream mode can simultaneously measure the concentration waveform and data of CO2, N2O anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children, and newborns. Advanced filters, can also be used in heavy humidity environments for a long time, reducing the cost of use.
  • There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.

Reviews

There are no reviews yet.

Be the first to review “Sidestream Multigas Module AneSure-S”

Your email address will not be published. Required fields are marked *

Quick Comparison

Sidestream Multigas Module AneSure-S removeSpinal Epidural Pack removeSiare Morpheus LT Anaesthetic Machine removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeTimesco Jumper Fingertip Pulse Oximeter removeTimesco Eclipse McCoy Laryngoscope Set remove
NameSidestream Multigas Module AneSure-S removeSpinal Epidural Pack removeSiare Morpheus LT Anaesthetic Machine removeRender SD-M2000A(P) Transport/Portable Anesthetic Machine removeTimesco Jumper Fingertip Pulse Oximeter removeTimesco Eclipse McCoy Laryngoscope Set remove
ImageFingertip Pulse OximeterTimesco Eclipse McCoy Laryngoscope Set
SKUSF1033560130170-12SF1033560084-25SF1033560101- 3SF1033560011-12SF1033560084-2SF1033560084-54
Rating
Price

$0.00

$0.00

$0.00

$1,320.00

$17.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad he Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. Delivery & Availability: Typically 15 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In Stock Sirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution
Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side Stream Mode
Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug And Play
The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.
  • Automatic Pressure Compensation
There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision
Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.  
Specifications of Anesthesia Multi-gas Detector AneSure-S
Working condition 5°C to 50°C, 10 to 90% RH, non-condensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
EtCO2, FiCO2 measurement Range:0-150 mmHg, 0-20 kPa, 0-19.7% Accuracy:±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
Respiration rate Range: 3-150 BPM Accuracy: ±1% of reading or ±1 rpm whichever is greater
FiN2O, EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading) 8-12%: unspecified
FiSEV, EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading) 10-15%: unspecified
FiDES, EtDES measurement Range:0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading) 18-25%: unspecified
Gas compensation O2 (HOST supplied), or automatic compensation if O2 equipped
Barometric Pressure Having a barometric pressure sensor and automatic compensation
Warm-up time 10 seconds reach the designed deviation of 97%, 20 seconds reach the designed deviation.
Rise times (t10- 90 %) CO2:<200ms N2O, AGENT: <300ms
Flow control Range: 50-250ml/min adjustable Accuracy: <±20%
Calibration No need to calibrate
Zero Implement when the gas value's offset is observed, or when any unspecified accuracy message is displayed
 
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution. Equipped with Oxygen battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side stream mode can simultaneously measure the concentration waveform and data of CO2, N2O anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children, and newborns. Advanced filters, can also be used in heavy humidity environments for a long time, reducing the cost of use.
  • There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.
It is for performing spinal/epidural or combined spinal/epidural or never-block loco-regional anaesthesia on patinet in clinical surgery. Component:
  • Epidural needle 16G,
  • Epidural catheter,
  • Epidural filter 0.2 um,
  • Catheter connector,
  • LOR syringe
The Morpheus LT is an anesthetic machine suitable for treatment of adults, children and new-borns. lt is provided with a mechanical 3-gas flowmeters group and a group tor rapid connection of two vaporizers in line and it is supplied with an advanced manual ventilation system, APL system, or AUX system with traditional To-and-Fro valve switched on and off automatically by ventilator. The unit frame is made tor 30% of light alloy and for 70% of fullyrecyclable plastic materiai. Thanks to the materiai used, the Morpheus has a total weight of less than 80 kgs. LUNG VENTILATOR The ventilator works by a microprocessor electronic control system with a simple and intuitive interface, which allows the anesthetist to operate in a clear and safe way. The system is provided with 3 dedicated software to have automatically the default settings for adult and paediatric patients and new-borns. lt is provided with the automatic compensation of dead space, the leakages calculation and the automatic calibration of Fi02. Operative Modes: MAN VC-VC PCV-APCV APCV P -SIMV V- SIMV Measured parameters: PAW RATE VM - VTE T INSP Fi02 MANUAL VENTILATION SYSTEM The Morpheus is equipped with an advanced manual ventilation system that can be switched on and off automatically by the ventilator; the operator can select the APL system or the AUX system with traditional T-and-Fro valve and 02 by pass safety system. BREATHING SYSTEM The patient group of Morpheus LT is compact, lightweight for manual removal and fully autoclavable. The patient circuit group is supplied with an automatic heating system avoiding humidity with possibility to use reusable and rechargeable CO, absorbers (TOP SPECIAL) of 1 kg. Absorber is with quick-release enabling replacement also during anaesthesia. The group is supplied with an exposed bellow that can be manually inspected. The MorpheusLT is equipped with 3 wide and large drawers and a large work-shelf to facilitate operating rooms procedures.
Click Here To Download Catalogue
  • High quality & Durability Design
  • Easy operation & easy maintenance
  • Compact construction
  • Beautiful & delicate
  • Space saving for operation room.
 
Click Here To download Catalogue
   
 
Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User ManualSirius-XL Eclipse blades feature a flexible tip designed for difficult intubations and are available in Macintosh 4, 3 and 2. Supplied as a blade only in a case or as a blade and handle set in a case.
  • The non-replaceable glass fibre bundle is fully enclosed in the blade which allows easy cleaning.
  • Rigid metal construction from fully autoclaveable, antimagnetic stainless steel.
  • Lever positioned at the rear of the blade to control the tilting tip.
  • 3 metal ball bearings for secure fitting.
  • Green ISO 7376 fitting metal block compatible with fibre optic handles.
  • Tilting tip for elevation of the epiglottis, providing an improved view of the larynx, without excessive force.
  • Atraumatic distal end.
  • Fully autoclaveable metal blade, covered by a 5 year guarantee or 4,000 autoclaves, whichever is sooner.
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare