Sidestream Multigas Module AneSure-S

$0.00

Shipped From Abroad

Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130170-12
Brands:: Kingst

Description

Features of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution

Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.

  • Side Stream Mode

Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.

  • Plug And Play

The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.

  • Automatic Pressure Compensation

There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.

  • High-precision

Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.

 

Specifications of Anesthesia Multi-gas Detector AneSure-S
Working condition 5°C to 50°C, 10 to 90% RH, non-condensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
EtCO2, FiCO2 measurement Range:0-150 mmHg, 0-20 kPa, 0-19.7%

Accuracy:±2mmHg for CO2 range 0 – 40mmHg

±5% for CO2 range from 41 – 70mmHg

±8% for CO2 range from 71 – 100mmHg

±10% Over 100mmHg

Respiration rate Range: 3-150 BPM

Accuracy: ±1% of reading or ±1 rpm whichever is greater

FiN2O, EtN2O measurement Range: 0-100%

Accuracy: ± (2 vol% + 2% of reading

FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12%

Accuracy: 0-8%: ± (0.15 vol% + 5% of reading)

8-12%: unspecified

FiSEV, EtSEV measurement Range: 0-15%

Accuracy: 0-10%: ± (0.15 vol% + 5% of reading)

10-15%: unspecified

FiDES, EtDES measurement Range:0-25%

Accuracy: 0-18%: ± (0.15 vol% + 5% of reading)

18-25%: unspecified

Gas compensation O2 (HOST supplied), or automatic compensation if O2 equipped
Barometric Pressure Having a barometric pressure sensor and automatic compensation
Warm-up time 10 seconds reach the designed deviation of 97%,

20 seconds reach the designed deviation.

Rise times (t10- 90 %) CO2:<200ms

N2O, AGENT: <300ms

Flow control Range: 50-250ml/min adjustable

Accuracy: <±20%

Calibration No need to calibrate
Zero Implement when the gas value’s offset is observed, or when any unspecified accuracy message is displayed

 

Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution. Equipped with Oxygen battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side stream mode can simultaneously measure the concentration waveform and data of CO2, N2O anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children, and newborns. Advanced filters, can also be used in heavy humidity environments for a long time, reducing the cost of use.
  • There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy for a temperature range of – 5-50 °C and in the range of 0 – 20%.

Reviews

There are no reviews yet.

Be the first to review “Sidestream Multigas Module AneSure-S”

Your email address will not be published. Required fields are marked *

Quick Comparison

Sidestream Multigas Module AneSure-S removeKIT FOR THORACENTESIS & PARACENTESIS removeElastomeric Pump (Disposable Infusion Pump) with PCA removeTimesco Jumper Fingertip Pulse Oximeter removeAnesthetic Face Mask removeOxygen Concentrator 3Ltr. remove
NameSidestream Multigas Module AneSure-S removeKIT FOR THORACENTESIS & PARACENTESIS removeElastomeric Pump (Disposable Infusion Pump) with PCA removeTimesco Jumper Fingertip Pulse Oximeter removeAnesthetic Face Mask removeOxygen Concentrator 3Ltr. remove
ImageFingertip Pulse Oximeter
SKUSF1033560130170-12SF1033560130101-5SF1033560084-18SF1033560084-2SF1033560084-141SF1033560084-40
Rating
Price

$0.00

$0.00

$0.00

$17.00

$8.00

$273.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Side stream Anesthesia Multi-Gas sensor can simultaneously measure the concentration waveform and data of CO2, N2O, anesthetic gases, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In Stock Integrated with SPO2 probe and processing display module. Small in volume、light in weight and convenient in carrying. Operation of the product is simple ,low power consumption. SPO2 , PR and Ridisplay,. Pulse rate value display, bar graph display. Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage. Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Four sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
R&D Capacity: OEM, ODM, Other
Payment Terms: LC, T/T, PayPal
Customized: Customized
Certification: CE, FDA, ISO13485
Scale: Medium
Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Features of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution
Reliable multi-gas OEM solution. Equipped With Oxygen Battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side Stream Mode
Can simultaneously measure the concentration waveform and data of CO2, N2O, Anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug And Play
The host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children and newborns. Advanced filter, can also be used in heavy humidity environment for a long time, reducing the cost of use.
  • Automatic Pressure Compensation
There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision
Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure the measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.  
Specifications of Anesthesia Multi-gas Detector AneSure-S
Working condition 5°C to 50°C, 10 to 90% RH, non-condensing
Circumstance pressure 55-115kpa
Power consumption <180 mA
Interface RS-232/Standard E-8-1, 38.4 kBaud,10 ms data interval (KM) or customization
EtCO2, FiCO2 measurement Range:0-150 mmHg, 0-20 kPa, 0-19.7% Accuracy:±2mmHg for CO2 range 0 - 40mmHg ±5% for CO2 range from 41 - 70mmHg ±8% for CO2 range from 71 - 100mmHg ±10% Over 100mmHg
Respiration rate Range: 3-150 BPM Accuracy: ±1% of reading or ±1 rpm whichever is greater
FiN2O, EtN2O measurement Range: 0-100% Accuracy: ± (2 vol% + 2% of reading
FiHAL/EtHAL, FiENF/EtENF, FiISO/EtISO measurement Range: 0-12% Accuracy: 0-8%: ± (0.15 vol% + 5% of reading) 8-12%: unspecified
FiSEV, EtSEV measurement Range: 0-15% Accuracy: 0-10%: ± (0.15 vol% + 5% of reading) 10-15%: unspecified
FiDES, EtDES measurement Range:0-25% Accuracy: 0-18%: ± (0.15 vol% + 5% of reading) 18-25%: unspecified
Gas compensation O2 (HOST supplied), or automatic compensation if O2 equipped
Barometric Pressure Having a barometric pressure sensor and automatic compensation
Warm-up time 10 seconds reach the designed deviation of 97%, 20 seconds reach the designed deviation.
Rise times (t10- 90 %) CO2:<200ms N2O, AGENT: <300ms
Flow control Range: 50-250ml/min adjustable Accuracy: <±20%
Calibration No need to calibrate
Zero Implement when the gas value's offset is observed, or when any unspecified accuracy message is displayed
 
Application Scenarios of Anesthesia Multi-gas Detector AneSure™-S
  • Reliable multi-gas OEM solution. Equipped with Oxygen battery. Compatible with a variety of protocols, so that your products can be quickly upgraded and assembled.
  • Side stream mode can simultaneously measure the concentration waveform and data of CO2, N2O anesthetic gas, as well as respiratory rate. The types of anesthetic gases measured include halothane, enflurane, isoflurane, sevoflurane, and desflurane. The user can manually select the type of anesthetic gas.
  • Plug and play, the host does not need an internal circuit, just a serial port. The sampling pump with super long service life can measure data within 4 seconds after power on. Suitable for adults, children, and newborns. Advanced filters, can also be used in heavy humidity environments for a long time, reducing the cost of use.
  • There is a built-in atmospheric pressure sensor, which is suitable for various altitude ranges.
  • High-precision. Careful selection of infrared devices, hardware design, and software algorithm, to achieve a high signal-to-noise ratio, to ensure measurement accuracy for a temperature range of - 5-50 °C and in the range of 0 - 20%.

KIT FOR THORACENTESIS & PARACENTESIS

The device is used to drain ascitic fluid and pleural liquid, it contains everything necessary for performing thoracentesis and paracentesis procedure (needles  syringe and collection bag). Products are customized upon request.  
Reference Description Qty per box
H92000E TORASET 1-55 30 pcs
H92010E TORASET 1-80 30 pcs
H92020E TORASET 1-VER 30 pcs
H92030E TORASET2-55 30 pcs
H92040E TORASET 2-80 30 pcs
H92050E TORASET 2-VER 30 pcs
H92001E TORAMATIC 1-55 30 pcs
H92011E TORAMATIC 1-80 30 pcs
H92021E TORAMATIC 1-VER 30 pcs
H92120E PARASET 2 30 pcs
H92160E PARASET 5 20 pcs
H92200E PARASET 8 20 pcs
H92240E PARASET 12 15 pcs
 
Click here to download Catalogue
This product make the tension of silicon capsule as the driving force to control the flow by micro porous tube, it was pre-selected by doctor base on patients'situation, and then and then handed over to the patients ' self- management “to relieve or ease the pain Product Components: one-way valve medicated device, elastic liquid storage device, liquid medicine filter, current limiting device, automatic liquid feeding device ( CBI & PCA ), pipe and the external connector; Product Features: 1. The continued to liquid (CBI) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; 2. Continued to liquid + self control to liquid ( CBI+PCA ) make the drug-stored sac mechanical stretch as a driving force, limited the flow through the micro porous tube to the patient safely, effectively, slightly, continuous uniform injection of liquid to analgesic effect; Automatic medicated function is the patients can medicate according to pain independently. Extrusion pump body does not affect the liquid normal velocity; liquid filtering device which can control the particles enter the body better; How to use: 1. Get analgesia pump out from sterile packaging, removing the cap of medicine inlet and outlet; pour the analgesic liquid in the liquid storage device, draw out the air from the liquid storage. 2. Finish medicating, waiting for the liquid outflow from the medicine outlet; please clamp tightly to stop flowing for preparation. 3. Control keys (PCA key) is a function key to add the medicine base on continue to medicated by patients' self-controlled. So the patients can self-control the PCA key under the guidance of doctors, according to the needs while they are in treatment. At the same time, doctor should fill in PCA treatment card, so that they can analyze the condition from PCA additional times.Integrated with SPO2 probe and processing display module • Small in volume, light in weight, convenient in carrying • Simple operation, lower power consumption • OLED screen display • SPO2, PR, bar graph of pulse, plethysmogram, blood perfusion index, battery indication display • 4 directions display, 6 display models, large fonts display • Brightness control, Demo mode, Setup menu • Movement interference • Alarm function and adjustable alarm parameters • Can be connected to mobile phones through Bluetooth; can support Android and iOS client • Auto power-off when no signal after 10s • Powered by 2*AAA alkaline batteries Specification: • Size: 62 x 37 x 32mm • Peak wavelength range of the light emitted from the probe: red light 660nm±3; infrared light 905nm±5 • Maximum optical output power of the probe: 1.2mW for infrared light (905nm) • Bluetooth module: 4.0 (single-mode) • Working temperature: 5℃ to 40℃ (41°F to 104°F) • Relative humidity: 15% to 80%, non-condensing • Atmospheric pressure: 70kPa to 106kPa • Rated voltage: DC 3V Package included: • 1 x JUMPER JPD-500F Bluetooth Fingertip Pulse Oximeter • 2 x AAA Batteries • 1 x Carry Case • 1 x Lanyard • 1 x English User ManualFour sizes from small adult to extra large adult. A range of color-coded economy anesthetic face masks for single patient use to prevent the possibility of cross infection. Features:
  • Soft cushion for patient comfort and air tight fit
  • Clear flexible housing and cushion for good patient visibility
  • Four sizes available, from small adultl to extra large adult
  • Each mask supplied with color-coded hook ring.
Our anesthesia system is a precision crafted, life-sustaining device. When moving to an O2 concentrator from tanks, you should expect the same attention to detail. A full 8lpm O2 flowrate capability - gives better performance at lower flow rates 20psi pressure output - your anesthesia system was designed to work from pressure O2 concentrations average 93% +/- 3% Built-in Low O2 Concentration Alarm Small footprint of 15"x15"x22" Remarkably quiet Save money over time vs. tanks Eliminate contamination hazards of tanks coming and going in your facility Works with ALL manufacturer's brands of anesthesia systems
    • .
   
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare