Ultrasound-guided ophthalmic blocks ensure excellent anesthesia with high success rates for eye surgeries. PAJUNK’s SonoEye needle combines the proven Atkinson tip with the innovative Cornerstone Reflectors for optimum needle visibility under ultrasound.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130169-9
Brands:: Pajunk

Description

SonoEye Features & Advantages

Cornerstone Reflectors

360° graduations on the first 20 mm of the needle in two sections:

  • Optimized ultrasound visibility of the needle shaft4
  • Reliable and optimized needle echogenicity at higher insertion angles.

Echogenic Needle Tip

  • Atkinson tip
  • Improved needle tip visibility under ultrasound

Reviews

There are no reviews yet.

Be the first to review “SonoEye-Echogenic Needle for Ultrasound-Guided Retrobulbar Blocks”

Your email address will not be published. Required fields are marked *

Quick Comparison

SonoEye-Echogenic Needle for Ultrasound-Guided Retrobulbar Blocks removeTonometer removeSlit Lamp removeApplanation Tonometer removeTimesco Ophthalmoscope removePortable Rebound Tonometer remove
NameSonoEye-Echogenic Needle for Ultrasound-Guided Retrobulbar Blocks removeTonometer removeSlit Lamp removeApplanation Tonometer removeTimesco Ophthalmoscope removePortable Rebound Tonometer remove
ImageMecan Tonometer YZ7AMecan SLM-JX Slit Lamp SerialMecan Applanation Tonometer YZ30XTimesco OphthalmoscopeMecan SW-500 Portable Rebound Tonometer
SKUSF1033560130169-9SF1033560107-9SF1033560107-15SF1033560107-1SF1033560084-282SF1033560107-17
Rating
Price

$0.00

$220.00

$1,375.00

$0.00

$140.00

$1,815.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Ultrasound-guided ophthalmic blocks ensure excellent anesthesia with high success rates for eye surgeries. PAJUNK’s SonoEye needle combines the proven Atkinson tip with the innovative Cornerstone Reflectors for optimum needle visibility under ultrasound.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad
  • Top Optical System.
  • High eyepoint, comfort.
  • Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
  • High Definition Eyepieces, More Comfortable for Viewing.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Shipped from abroad The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
In Stock
  • Durable and light weight
  • Supplied in a soft pouch
  • Long life bright white Xenon bulb
  • Macular beam dioptres lenses from 0 to +20 and 0 to -20
  • 3 year guarantee (excludes consumables)
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.    
Shipped from abroad Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data.
Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.  
Content
SonoEye Features & Advantages

Cornerstone Reflectors

360° graduations on the first 20 mm of the needle in two sections:
  • Optimized ultrasound visibility of the needle shaft4
  • Reliable and optimized needle echogenicity at higher insertion angles.
Echogenic Needle Tip
  • Atkinson tip
  • Improved needle tip visibility under ultrasound
This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth. Features:
  • Schiotz type
  • All the parts that contact the cornea are made of stainless steel and are anti-acid, which does no harm to issues
  • The instrument is safe, reliable, accurate, and convenient to carry
Slit Lamp Features:
  • Top Optical System.
  • High eyepoint, comfort.
  • Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
  • High Definition Eyepieces, More Comfortable for Viewing.
Technical Specifications:
Microscope Type Galileo Parallel
Optics Super Optic System
Magnification Change Way Drum Rotation
Eyepiece Magnification 12.5x
Total Magnifications 6x 10x, 16x, 25x, 40x
Diopter Adjustment -5D ~+5D
Slit Width 0-14MM Continuous
Slit Height 1-14MM Continuous
Slit Angle 0°- 180° Adjustable
Light Source LED
Light Spot Diameter 0.2mm,  2mm, 3mm, 5mm, 10mm, 14mm
Filter Heat Absorption; Grey; Redfree; Cobalt Blue
Fixation Red LED
Electrical
Illumination Bulb LED
Input Voltage 110V/220V (±10%)
Applanation Tonometer Interface Included
 
Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type). Features of Applanation Tonometer:
  • When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
  • Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
  • Directly get the ocular pressure and do not need to look up the conversion table.
  • The measured ocular pressure is not affected by hardness of eye.
  • The affected?ocular volume is just 0.56 cubic millimeter.
  • Adjustable measuring pressure ensures the long-term stability and reliability.
Technical Specifications Applanation Tonometer:
  • Measuring Range: 0~1064 Kpa
  • Light Ring Displacement: 1.53×2=3.06mm
  • Diameter of Prism Head: 7mm
  • Moving Range of Prism Head: 3mm
Timesco Ophthalmoscope features a head made from lightweight hermetically sealed durable plastic, precision optics and a latex free rubber eyebrow rest. A bright white light from long life standard bulbs provides crystal clear illumination in ophthalmic diagnostic procedures.
  • Durable and lightweight
  • Supplied in a soft pouch
  • Long life bright white Standard bulb
  • Macular beam dioptres lenses from 0 to +20 and 0 to -20
  • 3-year guarantee (excludes consumables)
Click Here To Download Catalogue 
Tonometer SW-500 with vertical and horizontal two working modes, wireless output print data. The equipment is used to measure intraocular pressure, using the principle of:  the probe hits the surfaces of different hardness at a certain speed, has a different reaction when the probe rebounds. Be of advantages of high accuracy, portable, without anesthesia, without the cross-infection, etc. Features:
  • Measurement can go along both in standing and lying posture
  • Wireless data printing
  • Easy to learn, easy to use
  • Lightweight and handy
  • No anesthesia, avoiding discomfort reaction
Technical Specifications:
Performance Index:
Measuring Range : 3mmHg~70mmHg
Measuring Error: ±1.5mmHg(3mmHg≤intraocular pressure≤25mmHg)
±2.5mmHg(25mmHg<intraocular pressure≤70mmHg)
Environment Requirement:
Transport and Storage: Ambient temperature:-20℃~+55℃
Relative moisture:≦95%
Atmosphere pressure:500hPa~1060hPa
Running: Ambient temperature:+5℃~+40℃
Relative moisture:≦80%
Atmosphere pressure:700hPa~1060hPa
Rating voltage: DC3V(2 AA Batteries)
Rating input power:1VA
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare