Ultrasound-guided ophthalmic blocks ensure excellent anesthesia with high success rates for eye surgeries. PAJUNK’s SonoEye needle combines the proven Atkinson tip with the innovative Cornerstone Reflectors for optimum needle visibility under ultrasound.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Ultrasound-guided ophthalmic blocks ensure excellent anesthesia with high success rates for eye surgeries. PAJUNK’s SonoEye needle combines the proven Atkinson tip with the innovative Cornerstone Reflectors for optimum needle visibility under ultrasound.
Delivery & Availability:Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Ship from abroad
Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
Durable and easy to operate
Easily and intuitively read the sphere focal scale value
High eco-friendly materials
Design fitting the face curve and no stimulation
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad
The product is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad
Super lightweight design, reduce fatigue, operation is very convenient.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad
Top Optical System.
High eyepoint, comfort.
Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
High Definition Eyepieces, More Comfortable for Viewing.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from abroad
This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
SonoEye Features & Advantages
Cornerstone Reflectors
360° graduations on the first 20 mm of the needle in two sections:
Optimized ultrasound visibility of the needle shaft4
Reliable and optimized needle echogenicity at higher insertion angles.
Echogenic Needle Tip
Atkinson tip
Improved needle tip visibility under ultrasound
Features:
Equipped with comprehensive measuring functions, it provides SPH, CYL, AXIS and pupil distance optometry
Durable and easy to operate
Easily and intuitively read the sphere focal scale value
High eco-friendly materials
Design fitting the face curve and no stimulation
Easy to take and clean
Free switch between the cross-cylindrical lens and the rotary prism
When the rotating risk is turning by the sphere, it can make sphere power adjust 3.00D for big scope.
It is designed expediently and smartly for a particular cross cylinder. Supporting supplementary lens could increase scope of measurement.
Technical Specifications:
Sphere
Range:-19.00~+16.75m-1 Step: 0.25m-1, 3.00m-1
Cylinder
Range: 0.00~-6.00m-1(Measuring Range With Accessories0.00~-8.00m-1) Step: 0.25m-1
Cylinder Axis
Range: 0~180°, Step:5°
Distance of Optical center (also known as Pupil)
Range: 50~75mmStep: 1mm
Sight Switch
Range:∞~380mm (distance of Optical center is64mm)
Front Chin Test
Range: 0~16mm
Distance (from cornea vertex to the lens surface)
16mm
Standard Accessories Lens
two pieces of Auxiliary Cylinder -2.00m-1 and -0.12m-1 respectively
Standard Accessories
one piece of M2 Hexagon wrench , one piece of a Myopia Standard Card, two piece of Myopia Standard Card , one piece of standard card holder , a dust cover
Auxiliary Lens
“O”:Open aperture
“R”:Retinoscope lens
“R”:Retinoscope lens
“R”:Retinoscope lens
*Lens of +1.50m-1 ,It is suit for the distance of 67 centimeters
“P”:Polaroid
* it is used for examining the dioptric balance of eyes , Implicit strabismus and stereo vision
“RMV”:Red Vertical maddox
*Be used to examine Implicit strabismus
“RMH”:Red horizontal maddox
*Be used to examine Implicit strabismus
“WMV”:Plane Vertical Maddox
*Be used to examine Implicit strabismus
“WMH”:Plane horizontal maddox
*Be used to examine Implicit strabismus
“RL”:Red lens
*Be used to examine eye function, Blending function and Implicit strabismus
“GL”:Green lens
*Be used to examine eye function, Blending function and Implicit strabismus
“+”:Test mark of optical center adjustment
“+.12”:Dioptric of the Spherical Lens is +0.12m-1
*Be used for the semi-adjustment of sphere lens, 0.25m-1
“PH”:1mmPinhole lens
*Be used to exclude visual non-refractive errors of the tested eye
“6ΔU”:6ΔBottom-up prism
*Be used to examine the rotating prism with the detection of nearly horizontal squint
“10ΔI”:10ΔBottom-up prism
*Be used to examine the rotating prism with the detection of nearly horizontal squint
“±0.50”:Cross-cylindrical lens
*Be used to examine the corrected dioptric of the Presbyopia and spherical lens
“OC”:Black lens
size
338(L)×99(W)×292(H)mm
NW
about 5kg
Applanation Tonometer is designed on the principle basis of Goldman tonometer. It can be connected with slit lamp(Carl Zeiss type).
Features of Applanation Tonometer:
When used with slit lamp, it can be used to examine the eyes and measure ocular pressure.
Accurate measurement and total tolerance are less than 0.066KPa(0.55Hg).
Directly get the ocular pressure and do not need to look up the conversion table.
The measured ocular pressure is not affected by hardness of eye.
The affected?ocular volume is just 0.56 cubic millimeter.
Adjustable measuring pressure ensures the long-term stability and reliability.
LED bulb(low-temperature,low-pressure,high-brightness) with long lifetime to make the illumination uniformly and bright. The illumination brightness can be adjusted continuously.
Imaging clearly,strong dimensional sense and large field of view range.The main body part of this device adopts engineering plastics and is designed to be compact and exquisite.
Super lightweight design, reduce fatigue,operation is very convenient.
The portable power supply is suitable for surgery, ward round and consultation.
This device is equipped with color filter,teaching mirror and sclera depressor to be more handy in operation.
Technical Specifications:
Pupilary Adjustment
52mm~74mm adjustable
Intensity of Illumination
continuous adjustment with the maximum intensity no less than 500Lx
Five steps drum zoom design, easier to use 6x, 10x, 16x, 25x, 40x magnification.
High Definition Eyepieces, More Comfortable for Viewing.
Technical Specifications:
Microscope Type
Galileo Parallel
Optics
Super Optic System
Magnification Change Way
Drum Rotation
Eyepiece Magnification
12.5x
Total Magnifications
6x 10x, 16x, 25x, 40x
Diopter Adjustment
-5D ~+5D
Slit Width
0-14MM Continuous
Slit Height
1-14MM Continuous
Slit Angle
0°- 180° Adjustable
Light Source
LED
Light Spot Diameter
0.2mm, 2mm, 3mm, 5mm, 10mm, 14mm
Filter
Heat Absorption; Grey; Redfree; Cobalt Blue
Fixation
Red LED
Electrical
Illumination Bulb
LED
Input Voltage
110V/220V (±10%)
Applanation Tonometer Interface
Included
This product is used to measure the intraocular pressure (IOP) by measuring the depth produced on the surface of the cornea by a load of a known weight. Each division on the scale corresponds to 1/20mm corneal depth.
Features:
Schiotz type
All the parts that contact the cornea are made of stainless steel and are anti-acid, which does no harm to issues
The instrument is safe, reliable, accurate, and convenient to carry
Reviews
There are no reviews yet.