STERISHRED 250

$0.00

Shipped From Abroad

THE ON-SITE SOLUTION TO CONVERT INFECTIOUS MEDICAL WASTE INTO MUNICIPAL

TRASH IN MINUTES!

STERISHRED 250 is a modern compact on-site solution for treating infectious healthcare waste using a non-burn thermal process (steam sterilization) at 135°C. It simultaneously shreds and sterilizes biohazardous waste including sharps in minutes!

Click here to download Catalogue
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF103356013097-4
Brands:: Tesalys

Description

Features

Ideal for bagged waste treatment

Its loading method facilitates the processing of medical waste in bags.

Easy to use

With an ergonomic interface, this solution offers a simple alternative to the treatment of waste with infectious risks.

 

Cycle speed and efficiency

STERISHRED® 250 allows to treat 15 to 25KG of infectious waste, in 40 to 50 min.

 

Technical Data

 

LOADING CHAMBER CAPACITY

170 L

DRAIN

Inner 32 mm Ø (heat resistant, floor level)

STEAM

Produced by the integrated steam generator, no external connection required

COMPRESSED AIR

Air compressor built-in

TOTAL CYCLE TIME

Approx. 30 to 35 min depending on steam generator version and load humidity

LOADING CAPACITY (KG/CYCLE)

10 to 25 kg/cycle (Based on an average waste density of 0,12 to 0,2 kg/l)

TOTAL CYCLE TIME IN WORKING CONDITIONS (2)

30 to 50 min

TREATMENT CAPACITY (KG/H) (3)

14 to 35 kg/h (Based on an average waste density of 0,12 to 0,2 kg/l)

EXTERNAL DIMENSIONS (HxWxD)

1918 mm (2765 incl. pusher) x 1900 mm x 1209 mm

NET WEIGHT

1 750 kg

LOADING CHAMBER

Stainless steel

TREATMENT CHAMBER

316L Stainless steel

STEAM GENERATOR

Stainless steel

WATER SOFTENER

Available as option (External)

WATER BOOSTER PUMP

Available as option (External)

WASTE SHREDDER

AISI 304L stainless steel (structure) Hardox® hard steel (blades)

PIPING

Stainless steel/PTFE flexible hosing

CHASSIS

Powder coated steel

BODYWORK

Stainless steel

CYCLE TRACEABILITY

Built-in printer

 

Utilities

 

WATER
Requirements Softened water 4-8°TH
Consumption Approx. 40 liters/cycle (15L machine + 25L steam generator)

 

ELECTRICITY
Requirements 380-400 V III N, 50/60 Hz, 40 Kw
Consumption 5 Kwh/cycle

Reviews

There are no reviews yet.

Be the first to review “STERISHRED 250”

Your email address will not be published. Required fields are marked *

Quick Comparison

STERISHRED 250 removeGenoray ZEN-7000 Surgical Mobile C-Arm removeKeewell Gel Warmer KGW-2 removeGenoray OSCAR 15 Surgical C-Arm Machine removeKeewell Gel Warmer KGW-1 removeAdvanced Infrared Vein Viewer (Vein VU 200) remove
NameSTERISHRED 250 removeGenoray ZEN-7000 Surgical Mobile C-Arm removeKeewell Gel Warmer KGW-2 removeGenoray OSCAR 15 Surgical C-Arm Machine removeKeewell Gel Warmer KGW-1 removeAdvanced Infrared Vein Viewer (Vein VU 200) remove
ImageGenoray OSCAR 15 Surgical C-Arm Machine
SKUSF103356013097-4SF1033560088SF1033560086SF1033560422-1SF1033560085SF1033560091
Rating
Price

$0.00

$0.00

$175.00

$0.00

$153.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad

THE ON-SITE SOLUTION TO CONVERT INFECTIOUS MEDICAL WASTE INTO MUNICIPAL

TRASH IN MINUTES!

STERISHRED 250 is a modern compact on-site solution for treating infectious healthcare waste using a non-burn thermal process (steam sterilization) at 135°C. It simultaneously shreds and sterilizes biohazardous waste including sharps in minutes!

Click here to download Catalogue
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Fluoroscopy Powerful, Light and Versatile Performance with the 9″ high-resolution image intensifier and million pixel (1K x 1K) high-definition camera, the Zen-7000 supports clear images without distortion to provide the best diagnostic imaging environment possible. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
A typical complaint in ultrasound procedures is the cold ultrasound gel. This device can safely heat the ultrasound gel to the body temperature. By this way it can remove the uncomfortable cold feeling of the patients, help the patients more relaxation to the diagnosis. At the same time, it can also improve the performance of the ultrasound gel, increase the image and signal quality. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The OSCAR 15 is a culmination of several years worth of developmental experience from Genoray. With CMOS imaging excellence & 15kW HFG you diagnosis need will be met while improving your productivity especially DSA (Digital Subtraction Angiography). Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped From Abroad
A typical complaint in ultrasound procedures is the cold ultrasound gel. This device can safely heat the ultrasound gel to the body temperature. By this way it can remove the uncomfortable cold feeling of the patients, help the patients more relaxation to the diagnosis. At the same time, it can also improve the performance of the ultrasound gel, increase the image and signal quality. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Ship From Abroad
Mechanical Characteristics: * Size: 215(I) x 55(w) x 70(h) mm * Weight: 390 g Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
 
Contenthttps://youtu.be/W2QTSINChh4?si=eVUr9251lLvOZlmZ
Features

Ideal for bagged waste treatment

Its loading method facilitates the processing of medical waste in bags.

Easy to use

With an ergonomic interface, this solution offers a simple alternative to the treatment of waste with infectious risks.  
Cycle speed and efficiency
STERISHRED® 250 allows to treat 15 to 25KG of infectious waste, in 40 to 50 min.
 
Technical Data
 
LOADING CHAMBER CAPACITY

170 L

DRAIN

Inner 32 mm Ø (heat resistant, floor level)

STEAM

Produced by the integrated steam generator, no external connection required

COMPRESSED AIR

Air compressor built-in

TOTAL CYCLE TIME

Approx. 30 to 35 min depending on steam generator version and load humidity

LOADING CAPACITY (KG/CYCLE)

10 to 25 kg/cycle (Based on an average waste density of 0,12 to 0,2 kg/l)

TOTAL CYCLE TIME IN WORKING CONDITIONS (2)

30 to 50 min

TREATMENT CAPACITY (KG/H) (3)

14 to 35 kg/h (Based on an average waste density of 0,12 to 0,2 kg/l)

EXTERNAL DIMENSIONS (HxWxD)

1918 mm (2765 incl. pusher) x 1900 mm x 1209 mm

NET WEIGHT

1 750 kg

LOADING CHAMBER

Stainless steel

TREATMENT CHAMBER

316L Stainless steel

STEAM GENERATOR

Stainless steel

WATER SOFTENER

Available as option (External)

WATER BOOSTER PUMP

Available as option (External)

WASTE SHREDDER

AISI 304L stainless steel (structure) Hardox® hard steel (blades)

PIPING

Stainless steel/PTFE flexible hosing

CHASSIS

Powder coated steel

BODYWORK

Stainless steel

CYCLE TRACEABILITY

Built-in printer

 
Utilities
 
WATER
Requirements Softened water 4-8°TH
Consumption Approx. 40 liters/cycle (15L machine + 25L steam generator)
 
ELECTRICITY
Requirements 380-400 V III N, 50/60 Hz, 40 Kw
Consumption 5 Kwh/cycle

Fluoroscopy Powerful, Light and Versatile Performance with the 9″ high-resolution image intensifier and million pixel (1K x 1K) high-definition camera, the Zen-7000 supports clear images without distortion to provide the best diagnostic imaging environment possible.

Exceptional Image Quality
  • 9" or 12” image intensifier
  • 1K x 1K High resolution CCD Camera
  • Wide FOV (Field-of-View)
  • Low Dose, Low Noise
  • High-Definition
  • High Contrast
  • Rotating Anode Tube
X-Ray Dose Management
  • Low Dose Mode
  • Auto / Virtual Collimator
Iris Collimator Compact & Intelligent Design
  • Lightweight Architecture
  • Intelligent operation
  • Compact, Hybrid Body
  • 7" Touch Screen LCD Monitor
19-inch LCD Two Monitor Powerful Software
  • Image Management
  • DICOM 3.0
  • Database Management
  • Approved Format
Air Cooling
  • High Performance
Protection from Overheating and Damage
Click Here To Download Catalogue
 
  A typical complaint in ultrasound procedures is the cold ultrasound gel. This device can safely heat the ultrasound gel to the body temperature. By this way it can remove the uncomfortable cold feeling of the patients, help the patients more relaxation to the diagnosis. At the same time, it can also improve the performance of the ultrasound gel, increase the image and signal quality. FEATURES: High bright LED display Adjustable temperature control range 34-40℃ Programmable timer to switch on and switch off 360 degree surround heater unit Digital temperature control technology High energy efficiency Ergonomic design Built-in durable waIl mountable construction STANDARDS CONFORMED TO: EN 55014-1: 2006+A1:2009 EN 55014-2: 1997+A2:2008 EN 61000-3-2: 2006+A2:2009 EN 61000-3-3: 2008 EN 60335-1: 2002+A1:2004+A11:2004+A12:2006+A2:2006+A13:2008+A14:2010 EN 62233:2008 SPECIFICATIONS: Power Supply:  AC100-240V, 50/60Hz, 30VA; DC12V, 2A Operating Ambient Temperature:  0-40℃ Operating Relative Humidity:  30-90% Temperature Control Range:  34-40℃ Temperature Control Accuracy:  ± 1℃ (After Heat Balance) Auto Switch On Timer:  00:00-23:59 Auto Switch Off Timer:  00:00-23:59The OSCAR 15 is a culmination of several years worth of developmental experience from Genoray. With CMOS imaging excellence & 15kW HFG you diagnosis need will be met while improving your productivity especially DSA (Digital Subtraction Angiography).  APPLICATION
  • General Surgery
  • Office based Vascular Center
  • Pain Management
  • Orthopdics
  • Urology
  • Cardiac Procedures
  • Hybrid OR
  • Neuro & Spine Surgery
  • Pain Management
  • Orthopedic Surgery
  • Trauma Procedure -Urology Procedure
  • Cardiac Surgery
  • Peripheral Artery Diseases -Vascular Surgery
  SPECIFICATION
  • 260 x 260 mm CMOS Type Flat-Panel detector for distortion-free imaging (High resolution images, Wide FOV, Low Noise)
  • 15kW HFG
  • 4"Touch LCD monitor
  • 43" LCD Monitor
  • Dual Foot Switch
  • DICOM 3.0 -CD/DVD Burner - USB Port
  • 800mm free space and 150° (+90°,-60°) orbital rotation, SID 1,000mm
  • 155º Dynamic Orbital Rotation
  • 2 kW Stationary Anode X-Ray Tube
  • 5 Million Images Storage Capacity
  FEATURE Exceptional Image Quality
  • With an optimal flat panel detector size of 26 x 26cm you won't miss a thing with its high quality resolution. It makes accurate diagnosis in a variety of departments especially DSA
Low Dose Mode     
  • Low dose mode is desgined to acquire reasonable image to diagnose the patient with minimum dosage.
Edge Enhancenment
  • For user to get more accurate diagnosis result enhancing edge of image.
Motion Correction
  • This function detects the movement and reduce the after image while exposing X-ray.
Metal Correction
  • To prevent over-dose radiation or low quality image casued by metal inturrption on field of view.
Virtual Collimator
  • The virtual collimator allows for the selection of your desired field of view, while reducing the amount of radiation exposure by limiting the X-Ray beam.
Auto Collimation
  • Prevention of unncessary X-Ray exposure by focusing on the area of interest while autmoatically collimating the remaining areas.
  POWERFULL SOFTWARE ZENIS A total solution from acquisition, storage, management, communication to print out. Provide convenient environment from user-centric interface. Diagnosis and confirm from recognizable simple icons. Convenience of database management.
  • Convenient diagnostic functions for easy patient / image management
  • Accurate diagnostic tools
  • Improve the efficiency of your hospital management
  • Perfect compatibility with all PACS
  • A must have for a digitally equipped hospital
  • Convenient communication and management for your customers
  • Dicom Support
  DIGITAL SUBTRACTION ANGIOGRAPHY Native DSA
  • Pairing fluoroscopy with constrast media to display the basic angiography views
Motion Matching
  • Selects the proper mask to apply and remove artifacts made by a patient's movement or breathing
Post-Processing
  • Processing: Improvement of the processed image after the DSA procedure
Landmarking / Brightness / Contrast
  • After setting the position for a vessel, the subject can be placed back to their original position by using the shift function to compensate for any movement. Allows for various functions that assist with accurately inserting a catheter.
Peak Opacification
  • Ability to diagnose a blood vessel with only a small amount of contrast media
Road Mapping, Land Mark
  • After setting a position for a vessel, the subject can be moved back to their original place by using the shift function to compensate for any movement. Provides various functions that helps accurately to insert a guide wire, catheter is compatible with the hybrid operating room.
Auto Roadmap Mask
  • Obtain blood vessel type information while only using a small amount of contrast media
Manual Roadmap Mask
  • Roadmap your vessels using a prevoiusly taken DSA image
Roadmap Pixel Shift
  • Re-position the roadmap mask by shifting the pixels to the proper position
Click Here To Download Catalogue
  A typical complaint in ultrasound procedures is the cold ultrasound gel. This device can safely heat the ultrasound gel to the body temperature. By this way it can remove the uncomfortable cold feeling of the patients, help the patients more relaxation to the diagnosis. At the same time, it can also improve the performance of the ultrasound gel, increase the image and signal quality. FEATURES: High bright LED display Adjustable temperature control range 34-40℃ Programmable timer to switch on and switch off 360 degree surround heater unit Digital temperature control technology High energy efficiency Ergonomic design Built-in durable waIl mountable construction STANDARDS CONFORMED TO: EN 55014-1: 2006+A1:2009 EN 55014-2: 1997+A2:2008 EN 61000-3-2: 2006+A2:2009 EN 61000-3-3: 2008 EN 60335-1: 2002+A1:2004+A11:2004+A12:2006+A2:2006+A13:2008+A14:2010 EN 62233:2008 SPECIFICATIONS: Power Supply:  AC100-240V, 50/60Hz, 30VA; DC12V, 2A Operating Ambient Temperature:  0-40℃ Operating Relative Humidity:  30-90% Temperature Control Range:  34-40℃ Temperature Control Accuracy:  ± 1℃ (After Heat Balance) Auto Switch On Timer:  00:00-23:59 Auto Switch Off Timer:  00:00-23:59Mechanical Characteristics: * Size: 215(I) x 55(w) x 70(h) mm * Weight: 390 g Electrical Characteristics: * Input Power: DC 15V / 3A * Battery Rating: 7.2V / 3,400 mAh * Battery Run Time: 3 Hours * Battery Charging Time: 2 Hours * Continuous Usage Time During Charging: 12 Hours *  Double Battery Protection Circuit Applied Product Information: Light Type:  Infrared *  Depth of visible vein: < 10mm
  • LED Lifetime: 20,000 Hours
* Projection Distance: 40cm ± 3cm *  Image Size: Small, Medium, Large *  Image Color: White, Black, Green *  Operation Mode: Normal, HD * Calibration: Accuracy of ± 200um *  Battery Detachable: Yes Additional Functions: *  System Status Information Display - Temperature, Device Age *  Automatic Control - Brightness, Fan Speed, Power Saving, etc.  
Click Here To Download Catalogue
WeightN/AN/A50 kgN/AN/AN/A
DimensionsN/AN/A120 × 350 × 150 cmN/AN/AN/A
Additional information
Weight 50 kg
Dimensions 120 × 350 × 150 cm
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare