StimuLong Sono ll-Stimulating Catheter-Through-Needle System
$0.00
Shipped From Abroad
The StimuLong Sono II combines the advantages of a stimulating catheter with those of echogenic needles. The StimuLongSono II catheter offers a stimulating tip that provides additional position control and confirmation. The system also allows for post-op stimulation for catheter tip placement confirmation.
The StimuLong Sono II sets are available with echogenic Tuohy and Facet Tip needles and are compatible with all PAJUNK nerve stimulators.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
StimuLong Sono ll Catheter Features & Advantages
Catheter with Stimulating, Open Tip
- Precise conductivity and stimulation capability due to gold-plated catheter tip
- Ensures double safety during placement
- Central opening – enables free flow of the anesthetic
Stainless Steel Helical Coil
- Improved ultrasound visibility
- Improved catheter flexibility and stability resulting in reduced chance of kinking6
- Radiopaque
Depth Markings
- Graduation on the first 30cm
- Easy determination of catheter positioning
- Easy to read and identify
Steel Stylet
- Provides the catheter with improved stability
- Is placed in the introductory aid at its end, and is removed automatically with the container after catheter placement
StimuLong Sono ll Needle Features & Advantages
Echogenic Needle Tip
- Improves needle tip visibility under ultrasound
Cornerstone Reflectors
360° graduations on the first 20 mm of the needle in two sections:
- Optimized ultrasound visibility of the needle shaft1.
- Reliable and optimized needle echogenicity at higher insertion angles.
NanoLine® Coating
- Very thin polymer film on inner and outer needle surface
- Excellent puncture and gliding properties through smooth surface
- Precise stimulation through the non-insulated needle tip
Depth Graduations
Quick Comparison
Settings | StimuLong Sono ll-Stimulating Catheter-Through-Needle System remove | ECG Electrodes remove | Patella Hammer remove | Plastic Fetoscope remove | Pen Touch remove | Foyomed Nasal Oxygen Cannula remove |
---|---|---|---|---|---|---|
Name | StimuLong Sono ll-Stimulating Catheter-Through-Needle System remove | ECG Electrodes remove | Patella Hammer remove | Plastic Fetoscope remove | Pen Touch remove | Foyomed Nasal Oxygen Cannula remove |
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() |
SKU | SF1033560084-143 | SF1033560084-110 | SF1033560084-100 | SF1033560084-99 | SF1033560084-24 | |
Rating | ||||||
Price |
| $12.00 | $2.50 | $4.20 | $3.00 | $1.30 |
Stock | ||||||
Availability | ||||||
Add to cart | ||||||
Description | Shipped From Abroad
The StimuLong Sono II combines the advantages of a stimulating catheter with those of echogenic needles. The StimuLongSono II catheter offers a stimulating tip that provides additional position control and confirmation. The system also allows for post-op stimulation for catheter tip placement confirmation.
The StimuLong Sono II sets are available with echogenic Tuohy and Facet Tip needles and are compatible with all PAJUNK nerve stimulators.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| In stock
| In stock
| In stock A practical way to reduce the exposure of pregnant women to ultrasound - listen to the baby''s heartbeat with Pinard Stethoscope, part of the midwife''s basic equipment. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In stock Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. | In Stock Foyomed Nasal Oxygen Cannula: The nasal cannula are used for patients needing only low-flow supplemental oxygen. Patients with breathing difficulties and conditions such as emphysema or other pulmonary pathologies require the nasal cannula. The flow rate for the cannula is around .5 to 4 liters per minute (LPM). All materials used in construction of the Oxygen Mask ,and the Oxygen Tubing are latex free, soft and smooth surface without sharp edge and object, They have no undesirable effects on the Oxygen/Medication passing through under ordinary conditions of use. Mask Material are hypoallergenic and shall resist ignition and rapid buring. Delivery & Availability: Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information. |
Content | StimuLong Sono ll Catheter Features & AdvantagesCatheter with Stimulating, Open Tip
Stainless Steel Helical Coil
Depth Markings
Steel Stylet
StimuLong Sono ll Needle Features & AdvantagesEchogenic Needle Tip
Cornerstone Reflectors
360° graduations on the first 20 mm of the needle in two sections:
NanoLine® Coating
Depth Graduations
| The Covidien/Kendall 200 series electrodes are a cost effective general adult monitoring electrode. The foam substrate repels fluids and conforms to body contours. The Covidien/Kendall™ 200 series electrodes have a smaller footprint for convenient lead placement and a teardrop shape for easy removal from the liner and patient. Many packaging configurations are offered to satisfy all customer needs. The patented conductive adhesive hydrogel is designed to stay fresh up to 45 days out of the package.
Features:
|
| A practical way to reduce the exposure of pregnant women to ultrasound - listen to the baby''s heartbeat with Pinard Stethoscope, part of the midwife''s basic equipment.
Advantages:
|
| Foyomed Nasal Oxygen Cannula: The nasal cannula are used for patients needing only low-flow supplemental oxygen. Patients with breathing difficulties and conditions such as emphysema or other pulmonary pathologies require the nasal cannula. The flow rate for the cannula is around .5 to 4 liters per minute (LPM). All materials used in construction of the Oxygen Mask ,and the Oxygen Tubing are latex free, soft and smooth surface without sharp edge and object, They have no undesirable effects on the Oxygen/Medication passing through under ordinary conditions of use. Mask Material are hypoallergenic and shall resist ignition and rapid buring.
Features:
|
Weight | N/A | N/A | N/A | N/A | N/A | N/A |
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A |
Additional information |
Reviews
There are no reviews yet.