The SURTRON EVAC is a surgical smoke evacuation and filtration system developed by LED SpA. It is designed to efficiently remove and filter the smoke generated during electrosurgical procedures, enhancing both safety and visibility in the operating room.

 

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: LED Surtron

Description

SURTRON EVAC is an aspiration and filtering system for the smoke produced during the surgical procedures. The smokes, generated during the surgical procedures, have a bad, strong, and long smell. These smokes consist of water vapour, organic gas, visible or invisible solid particles, and viral particles. So a good aspiration and filtration eliminates bad smells, reduces the bacteriologist and/or viral risks, and solves the particularly annoying problem of the optimal vision of the zone of the intervention, during the laparoscopic procedures. In SURTRON EVAC, the activation of the aspiration can be: AUTOMATIC, through an electronic system of survey of the activation of the high-frequency electrosurgical unit; or MANUAL, acting directly on the unit through a foot switch (optional). The flux of the aspiration can be regulated to be suitable for the singular necessities. For laparoscopic procedures, there is a specific function, quickly selectable. SURTRON EVAC has an electronic control of the aspiration with the indication of the status of the filters.

There are two different kinds of filters, quickly substitutable and constituted by a filtering ULPA type with an active carbon part dedicated to the elimination of the bad smells of the electrosurgical smokes and a connector of 7/8” (22mm). The filters have an electronic system for the control of the status of use.

The BLUE filter is the standard filter and it is included with the unit for the first time of use.

The RED filter is an optional spare part, created for a long time of use.

 

Technical Data
  • Input voltage 230 VAC or 115 VAC
  • Main frequency 50 Hz
  • Electrical input power 800 VA
  • Max vacuum flow rate 1000 LPM (35 CFM)
  • Max static suction 250 mbar (83 in H2O)
  • Filter type ULPA with active carbon
  • Filter efficiency 99,999X%
  • Particle diameter 0,12 micron
  • Max vacuum flow rate with filter 300 LPM (11 CFM)
  • Size WxHxD 370x144x319 mm
  • Weight 4 Kg

Reviews

There are no reviews yet.

Be the first to review “SURTRON EVAC-Vacuum and Filtering Smoke System”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsSURTRON EVAC-Vacuum and Filtering Smoke System removeArthroscopic Ablator removeOBS-350A Intelligent Versatile removeElectrosurgical Pad removeDisposable ECG Monitoring Electrode removeOBS-100B Cold Bipolar Coagulator remove
NameSURTRON EVAC-Vacuum and Filtering Smoke System removeArthroscopic Ablator removeOBS-350A Intelligent Versatile removeElectrosurgical Pad removeDisposable ECG Monitoring Electrode removeOBS-100B Cold Bipolar Coagulator remove
Image
SKUSF1033560130165-13SF1033560130165-5SF1033560130165-16SF1033560130165-24SF1033560130165-8
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The SURTRON EVAC is a surgical smoke evacuation and filtration system developed by LED SpA. It is designed to efficiently remove and filter the smoke generated during electrosurgical procedures, enhancing both safety and visibility in the operating room.  
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Excellent compatibility, available in vessel sealing, suitable for general surgery,vascular surgery, hepatobiliary and pancreatic surgery, cardiothoracic surgery, gastroenterology, TURP and TUVP, and compatible with cystoscopy, arthroscopy, laparoscopy and hysteroscopy
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Electrosurgical Pad, also known as a dispersive electrode or grounding pad, is a crucial component used in electrosurgery. It helps to complete the electrical circuit by dispersing the electrical current away from the patient's body, ensuring the safety and effective operation of the electrosurgical unit (ESU)
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad Disposable ECG Electrodes consist of snap set, conductive gel, backing material with medical adhesive, and release film. OBS Disposable ECG Electrodes model 301 are Non-woven, Micropore fabric backing Electrodes . These electrodes are applied by or on the order of a physician on a patient’s skin, the model 301 is fit for the general electrocardiographic application of both adults and children.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad The OBS-100B Cold Bipolar Coagulator is a precision electrosurgical device designed for delicate surgeries. It ensures minimal tissue irritation, offers a non-stick effect, and operates without sparking, making it ideal for microsurgical applications like neurosurgery and ophthalmology.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentSURTRON EVAC is an aspiration and filtering system for the smoke produced during the surgical procedures. The smokes, generated during the surgical procedures, have a bad, strong, and long smell. These smokes consist of water vapour, organic gas, visible or invisible solid particles, and viral particles. So a good aspiration and filtration eliminates bad smells, reduces the bacteriologist and/or viral risks, and solves the particularly annoying problem of the optimal vision of the zone of the intervention, during the laparoscopic procedures. In SURTRON EVAC, the activation of the aspiration can be: AUTOMATIC, through an electronic system of survey of the activation of the high-frequency electrosurgical unit; or MANUAL, acting directly on the unit through a foot switch (optional). The flux of the aspiration can be regulated to be suitable for the singular necessities. For laparoscopic procedures, there is a specific function, quickly selectable. SURTRON EVAC has an electronic control of the aspiration with the indication of the status of the filters. There are two different kinds of filters, quickly substitutable and constituted by a filtering ULPA type with an active carbon part dedicated to the elimination of the bad smells of the electrosurgical smokes and a connector of 7/8” (22mm). The filters have an electronic system for the control of the status of use. The BLUE filter is the standard filter and it is included with the unit for the first time of use. The RED filter is an optional spare part, created for a long time of use.  
Technical Data
  • Input voltage 230 VAC or 115 VAC
  • Main frequency 50 Hz
  • Electrical input power 800 VA
  • Max vacuum flow rate 1000 LPM (35 CFM)
  • Max static suction 250 mbar (83 in H2O)
  • Filter type ULPA with active carbon
  • Filter efficiency 99,999X%
  • Particle diameter 0,12 micron
  • Max vacuum flow rate with filter 300 LPM (11 CFM)
  • Size WxHxD 370x144x319 mm
  • Weight 4 Kg
Features

1. Intended for ablation,tissue modification, and coagulation of soft tissue in arthroscopic procedures such as hip,  shoulder, ankle, wrist, elbow, and knee. 2. The Extending shaft enables good visualization and easy insertion through subcutaneous tissue,and  well insulated coating guarantee its safety and reliability. 3.Irrigation/suction solution is available with a cannula and an adjustable flow control valve. 4. Tips in different shapes and angles fit in particular arthroscopic procedures. 5. Compatible with most electrosurgical generators.

Use Indication

This device should never be used when:

  • There is visible evidence of damage to the exterior of the device such as cracked or damaged plastic or connector damage.
  • These devices fail the inspection described herein.
  • In the presence of flammable gases, flammable prep solutions or drapes. Oxidizing. Gases such as Nitrous Oxide (N2O), or in oxygen-riched environments.
  • Do not use monopolar electrosurgery on small appendages, as in circumcision or finger surgery.
 
Features:
  1. High Conductivity: They are made from materials that ensure efficient conduction of electrical current.
  2. Large Surface Area: This helps in dispersing the current over a wide area, reducing the risk of burns.
  3. Adhesive Backing: They usually have an adhesive side to securely attach to the patient's skin.
  4. Flexible Design: They are designed to conform to the contours of the patient's body.
  5. Safety Mechanisms: Modern pads often include features like dual-pad return electrodes for fail-safe operation.
Uses:
  1. Completing the Electrical Circuit: They act as a return path for the electrical current used in electrosurgery.
  2. Minimizing Burns: By dispersing the current, they help prevent burns at the surgical site.
  3. Ensuring Patient Safety: They are crucial for the safe operation of electrosurgical units, especially in patients with electronic implants like pacemakers.
  4. Versatile Applications: Used in various surgical procedures, including cutting, coagulating, and desiccating tissue.
Indications for Use:

Disposable ECG Electrodes are pre-gelled, non-sterile, single use disposable electrocardiographic electrodes which are intended for use as an accessory to ECG equipment for ECG monitoring , diagnostic procedures and can used for stress test & holter.

Instruction for Use:

1. Clean the skin area where the electrode will stick on. Make sure the skin area for sticking is intact (uninjured). 2. Connect the leadwire with the electrode. Make sure it is fastened and in good contact. 3. Tear off the release film from the bottom (the part away from metal stud) of electrode. 4. Press lightly when stick the electrodes to the skin and make sure the conductive gel and adhesive backing stick on the skin tightly. Caution

  • Don’t peel the release film from the metal stud of the electrode. It may break the structure and affect the function of electrodes.
  • ECG electrodes should only be used by or in consultation with a healthcare provider familiar with their proper placement and use.
  • ECG electrodes may damage the skin if removed carelessly.
  • ECG electrodes should be applied only to intact, clean skin (e.g., not over open wounds, lesions, or infected, or inflamed areas).
  • Do not reuse this device. It may cause infection and affect the performance of the reuse of this device.
 
Features
  • Low voltage output: Ensures minimal irritation to neuromuscular tissues.
  • Sparkless operation: Reduces tissue sticking.
  • Superb non-stick effect: Enhances surgical precision.
  • Suitable for microsurgery: Ideal for neurosurgery, ophthalmology, gynecology, and plastic surgery
 