SURTRON TOUCH 200
$0.00
Shipped From Abroad
SURTRON TOUCH is a high-frequency electrosurgical equipment that is suitable for precision monopolar and bipolar surgery and micro-surgery without tissue alterations. SURTRON TOUCH can supply HF operative powers either for programmable time as short as hundreds of seconds. The unit, through its performances, allows pure CUT, cut-coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in the absence of necrosis SOFT COAG, bipolar CUT and COAG. The digital reading of the delivered power and the oversight through a microcontroller of the operational functions assure the absolute reliability of the conditions of work. SURTRON TOUCH allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows for the implementation of the surgical operation without turning the surgeon’s attention from the surgical field.
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Description
Technical data
- Max power PURE CUT
200 W – 300 Ω - Max power BLEND CUT
150 W – 200 Ω - Max power ENHANCED CUT
150 W – 300 Ω - Max power BIPOLAR TUR
200 W – 200 Ω - Max power BIPOLAR CUT
120 W – 50 Ω - Max power FORCED COAG
150 W – 200 Ω - Max power SOFT COAG
100 W – 200 Ω - Max power FULGURATION COAG
100 W – 1000 Ω - Potenza max BIPOLAR COAG
120 W – 50 Ω - Max power BIPOLAR SEALING
200 W – 50 Ω - Working frequency
360 kHz - RF power pulse emission time
10ms-30sec - RF power pulse interval
1-30 - Patient circuit F
- Selectable input voltage 100-240 VAC
- Mains Frequency 50-60 Hz
- Electrical input power: 750 VA
- Size WxHxD 370x144x319 mm
- Weight 6 kg
CONTROLS
Patient/Plate circuit monitoring
Output power monitoring
Self-check control
SAFETY
EN60601-1
EN60601-1-2
EN60601-2-2
Electrical classification: I CF
MDD 93/42 / EC: II b
Quick Comparison
Settings | SURTRON TOUCH 200 remove | OBS-350A Intelligent Versatile remove | OBS-50 High Frequency Coagulator remove | LOOPCUT II SERIES Disposable Electrosurgical Electrode remove | OBS-100C(I) Intelligent Electrosurgical Unit remove | Disposable ECG Monitoring Electrode remove | ||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Name | SURTRON TOUCH 200 remove | OBS-350A Intelligent Versatile remove | OBS-50 High Frequency Coagulator remove | LOOPCUT II SERIES Disposable Electrosurgical Electrode remove | OBS-100C(I) Intelligent Electrosurgical Unit remove | Disposable ECG Monitoring Electrode remove | ||||||||||||||||||||||||||||||||||||||
Image | ![]() | ![]() | ![]() | ![]() | ![]() | ![]() | ||||||||||||||||||||||||||||||||||||||
SKU | SF1033560130165-5 | SF1033560130165-3 | SF1033560130165-15 | SF1033560130165-2 | SF1033560130165-24 | |||||||||||||||||||||||||||||||||||||||
Rating | ||||||||||||||||||||||||||||||||||||||||||||
Price |
|
|
|
|
|
| ||||||||||||||||||||||||||||||||||||||
Stock | ||||||||||||||||||||||||||||||||||||||||||||
Availability | ||||||||||||||||||||||||||||||||||||||||||||
Add to cart | ||||||||||||||||||||||||||||||||||||||||||||
Description | Shipped From Abroad
SURTRON TOUCH is a high-frequency electrosurgical equipment that is suitable for precision monopolar and bipolar surgery and micro-surgery without tissue alterations. SURTRON TOUCH can supply HF operative powers either for programmable time as short as hundreds of seconds. The unit, through its performances, allows pure CUT, cut-coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in the absence of necrosis SOFT COAG, bipolar CUT and COAG. The digital reading of the delivered power and the oversight through a microcontroller of the operational functions assure the absolute reliability of the conditions of work. SURTRON TOUCH allows a highly professional surgery thanks to the user-friendly and safety solutions normally used. The connection of the neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the output functions as well as the delivery of output power, allows for the implementation of the surgical operation without turning the surgeon's attention from the surgical field.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Excellent compatibility, available in vessel sealing, suitable for general surgery,vascular surgery, hepatobiliary and pancreatic surgery, cardiothoracic surgery, gastroenterology, TURP and TUVP, and compatible with cystoscopy, arthroscopy, laparoscopy and hysteroscopy
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
This unit is widely used in many different sectors including plastic surgery, dermatology, ENT, Ophthalmology, somatology, gynecology, proctology, and urology.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Portable in size, available in both monopolar and bipolar modes, convenient handle power control and memory function, suitable for microsurgery, gynecology, and arthroscopy.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped From Abroad
Disposable ECG Electrodes consist of snap set, conductive gel, backing material with medical adhesive, and release film. OBS Disposable ECG Electrodes model 301 are Non-woven, Micropore fabric backing Electrodes . These electrodes are applied by or on the order of a physician on a patient’s skin, the model 301 is fit for the general electrocardiographic application of both adults and children.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| ||||||||||||||||||||||||||||||||||||||
Content | Technical data
|
The OBS-50 is a market leader across the world due to its ease of use, high security, power on self test, full-range monitoring, remote control and precise output.
Multiple Applications to meet your different clinic demandsDesiccation
| Features1. Stainless steel & non-stick finish 2. Hexagonal connection ring fitting the pencil locking design. 3. Different shapes fitting for different surgeries |
Key FeaturesOBS-100 Electrosurgical Generator with state-of-art technology offers superb performance on the electro-surgery, and shows remarkable safety, reliability and convenience. 1. Two levels of coagulation: pinpoint coagulation and fulguration Pinpoint coagulation provides precise control of bleeding in localized areas. Fulguration provides greater control of bleeding in highly vascular over-surface areas. 2. Presets The unit incorporates as many as ten user-defined presets for easy recall of frequency and settings. 3. Isolated RF output for Cut, Blend, and Coag modes This minimizes the potential of alternate site burns. 4. Ground Referenced RF output for Fulguration modes 5. Self-diagnostics These diagnostics continually monitor the unit to ensure proper performance. If the diagnostics is unsuccessful, the warning tones can be heard.Technical parameters:
| Indications for Use:
Disposable ECG Electrodes are pre-gelled, non-sterile, single use disposable electrocardiographic electrodes which are intended for use as an accessory to ECG equipment for ECG monitoring , diagnostic procedures and can used for stress test & holter. Instruction for Use:1. Clean the skin area where the electrode will stick on. Make sure the skin area for sticking is intact (uninjured). 2. Connect the leadwire with the electrode. Make sure it is fastened and in good contact. 3. Tear off the release film from the bottom (the part away from metal stud) of electrode. 4. Press lightly when stick the electrodes to the skin and make sure the conductive gel and adhesive backing stick on the skin tightly. Caution
| |||||||||||||||||||||||||||||||||||||||
Weight | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||
Dimensions | N/A | N/A | N/A | N/A | N/A | N/A | ||||||||||||||||||||||||||||||||||||||
Additional information |
Reviews
There are no reviews yet.