Ultrasonic Cell Disruptor

$0.00

Shipped From Abroad

This Ultrasonic Cell Disruptor is a device used to break open cells using high-frequency ultrasonic waves. This process, called sonication, disrupts cell membranes, releasing their contents. It’s widely used in molecular biology, biochemistry, and other lab settings for tasks like extracting DNA, proteins, or other cellular components. Handy tool for when you need to get to the good stuff inside cells!

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-125
Brands:: Scitek

Description

Ultrasonic cell disruptor is a multifunctional and versatile instrument that utilizes intense ultrasonic waves to create cavitation effects in a liquid environment for sonic processing of substances. It can be used for disruption of animal and plant tissues, cells, bacteria, and spores, as well as for emulsification, separation, dispersion, homogenization, extraction, degassing, cleaning, and acceleration of chemical reactions. Additionally, it can disperse and homogenize nanomaterials such as carbon nanotubes and graphite selenide, as well as disintegrate, emulsify, homogenize, and break down soil, rock samples, nonferrous metals, and rare earth materials.

 

Ultrasonic Cell Disruptor Features:
  1. Digital integration: Fully digital integrated circuit, with consistently stable amplitude output.
  2. Embedded lighting temperature measurement :Embedded lighting and temperature measurement system
  3. Integrated: The all-in-one machine integrates ultrasonic power supply and soundproof box, saving space.
  4. Continuous Operation: Capable of operating continuously for 24 hours, stable and reliable
  5. Electric Lift: Transducer electric lift for easy sample retrieval and placement
  6. Conversion Efficiency: The electrical power conversion efficiency is high and consistent.

Protection: Automatic tracking the frequency, fault alarm.over-temperature protection.

 

Ultrasonic Cell Disruptor Specifications:
Model UCD-I200 UCD-I300I UCD-I500 UCD-I600I UCD-I1000
Frequency(KHz) 19-25
Power(W) 150 250 650 950 1200
Display 8.8-inch touchscreen
Display Content Time, Power, Temperature, Real-time Frequency and etc
Duty Cycle 0.1-99﹪
Crushing Capacity (ml) 0.5-200 0.5-300 0.5-500 0.5-600 0.5-1000
Standard Amplitude-change Pole 0 (mm) 6 6 6 20 20
Optional Amplitude-change Pole 0 (mm) 2, 3, 6 2, 3, 6 2, 3, 6, 10 2, 3, 6, 10, 15 2, 3, 6, 10, 15, 20
Storage Capacity 18 groups of program data
Timer Function 0-999 minutes
Working Mode Gap or continuous
Temperature 0-99(℃)
Power Supply 220V/50Hz

Reviews

There are no reviews yet.

Be the first to review “Ultrasonic Cell Disruptor”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsUltrasonic Cell Disruptor removeSkyla Hi POC Clinical Chemistry Analyzer removeSugentech Inclix (POCT) Immunoassay Analyzer removeEppendorf Minispin Centrifuge removeIISM VPism-C (Compact Type) Vein Probe removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
NameUltrasonic Cell Disruptor removeSkyla Hi POC Clinical Chemistry Analyzer removeSugentech Inclix (POCT) Immunoassay Analyzer removeEppendorf Minispin Centrifuge removeIISM VPism-C (Compact Type) Vein Probe removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
ImageIISM VPism-C (Compact Type) Vein Probe
SKUSF1033560130127-125SF1033560060-2SF1033560084-89SF1033560084-116SF1033560090-1SF1033560060-1
Rating
Price

$0.00

$0.00

$0.00

$0.00

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad This Ultrasonic Cell Disruptor is a device used to break open cells using high-frequency ultrasonic waves. This process, called sonication, disrupts cell membranes, releasing their contents. It's widely used in molecular biology, biochemistry, and other lab settings for tasks like extracting DNA, proteins, or other cellular components. Handy tool for when you need to get to the good stuff inside cells!
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. Delivery & Availability: Typically 10 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
ContentUltrasonic cell disruptor is a multifunctional and versatile instrument that utilizes intense ultrasonic waves to create cavitation effects in a liquid environment for sonic processing of substances. It can be used for disruption of animal and plant tissues, cells, bacteria, and spores, as well as for emulsification, separation, dispersion, homogenization, extraction, degassing, cleaning, and acceleration of chemical reactions. Additionally, it can disperse and homogenize nanomaterials such as carbon nanotubes and graphite selenide, as well as disintegrate, emulsify, homogenize, and break down soil, rock samples, nonferrous metals, and rare earth materials.  
Ultrasonic Cell Disruptor Features:
  1. Digital integration: Fully digital integrated circuit, with consistently stable amplitude output.
  2. Embedded lighting temperature measurement :Embedded lighting and temperature measurement system
  3. Integrated: The all-in-one machine integrates ultrasonic power supply and soundproof box, saving space.
  4. Continuous Operation: Capable of operating continuously for 24 hours, stable and reliable
  5. Electric Lift: Transducer electric lift for easy sample retrieval and placement
  6. Conversion Efficiency: The electrical power conversion efficiency is high and consistent.
Protection: Automatic tracking the frequency, fault alarm.over-temperature protection.  
Ultrasonic Cell Disruptor Specifications:
Model UCD-I200 UCD-I300I UCD-I500 UCD-I600I UCD-I1000
Frequency(KHz) 19-25
Power(W) 150 250 650 950 1200
Display 8.8-inch touchscreen
Display Content Time, Power, Temperature, Real-time Frequency and etc
Duty Cycle 0.1-99﹪
Crushing Capacity (ml) 0.5-200 0.5-300 0.5-500 0.5-600 0.5-1000
Standard Amplitude-change Pole 0 (mm) 6 6 6 20 20
Optional Amplitude-change Pole 0 (mm) 2, 3, 6 2, 3, 6 2, 3, 6, 10 2, 3, 6, 10, 15 2, 3, 6, 10, 15, 20
Storage Capacity 18 groups of program data
Timer Function 0-999 minutes
Working Mode Gap or continuous
Temperature 0-99(℃)
Power Supply 220V/50Hz
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
INCLIX™ is an immunochromatographic analyzer providing immediate point-of-care testing (POCT) at patient care settings or clinical laboratories. It facilitates automatic detection of various biomarkers for cardiovascular disease, infectious disease, cancer, diabetes, allergy, and etc. with high accuracy and sensitivity. INCLIX™ analyzer is a compact, easy-to-use and cost-effective multi-parameter POCT instrument and its unique user friendly software provides an efficient data management system. Features: • Good accuracy owning to superior CMOS sensor & our own Algorism • 10,000 test results data storage • Instrument Check by Reference Kit • Remote Support available (when connected via Internet) • Built-in Thermal Printer and Barcode Scanner • Data export to USB(PDF, Excel), Email and LIS • Storage Temperature of Test Cassette & Buffer : Room temperature, 2 ~ 30 ℃ • Shelf Life of Test Cassette & Buffer : 24 months  
Click Here To Download Catalogue
 
Powerful and user-friendly MiniSpin Centrifuge are small enough so that each workstation can be equipped with a “personal” centrifuge. The rotor, inner centrifuge lid, and lid latch are made of metal for maximum operation safety. Features:
  • Rotor capacity: 12 x 1.5/2.0 mL vessels, 2 x PCR strip
  • Max. speed: 14,100 x g (14,500 rpm)
  • Extremely compact footprint — measures 9”W x 4.”H x 9ó”D!
  • Aluminum rotor accommodates twelve 1.5- or 2.0-mL tubes (maximum diameter of 11 mm)
  • Rotor can be autoclaved at 121°C for 20 minutes
  • Minimal sample heat transfer — maximum of 12°C after 20 minutes at max speed
  • Eliminate costly repairs with the low maintenance drive
  • Soft-touch lid closure for ergonomic lid locking — and releases automatically at the end of a run
Technical Specifications:
Speed: 800 – 13,400 rpm (100 rpm steps)
Capacity: 12 x 1.5/2.0 mL
Electrical: 120 V, 60 Hz
Dimensions: (W x D x H) 22.6 x 23.9 x 12.0 cm
Weight: 4.3 kg
 
Click Here To Download Catalogue
The iiSM VPism-C Vein Probe - Compact Unit is a compact, non-invasive infrared device to view blood vessels just beneath the skin. Includes a camera, touchscreen display, connector cable, power supply, camera stand, gooseneck arm, and instruction manual. This handheld, portable device is lightweight and includes the touchscreen and camera with attached clip. The camera can be removed and handled by hand, or can clip to the touchscreen unit for a hands-free experience. The back of the device also has a kickstand, so that physicians can stand the device on its own. The VPism-C can also be mounted to an armrest, if a patient needs to be stationary, or attached to a SLism-F Specialized Light Source for patients with deeper vessels. This device can be a vital tool in providing accurate placement of injections or other vascular treatments, such as for varicose veins. The infrared video shows the location of the veins and capillaries in real time, as well as save images for further discussion or diagnosis. For patients who have difficult-to-find veins, this device will save them from incorrect or painful injection sites. Features: Probe Target: Subcutaneous blood vessels of various patients (including capillaries) Probe Method: Non-invasive infrared technology Probe Depth: Within 10 mm under the skin Magnification Function: Up to 1X, 2X and 4X Automatic Adjustment Function: Adjusts the brightness automatically based on the targeted vein Specialized Light Function: Shows the veins more clearly by using the specialized light source Operation Method: Easy to operate with touchscreen Internal Battery Support: Continuous running time: 1.5 hours Warranty: 1 year
Click Here To Download Catalogue
 
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Model

Advanced, Advanced Plus, Basic, Smart

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare