Versatile Infrared Vein Finder

$0.00

Shipped From Abroad

Model: VF-X2

The rugged and easy-to-use VF-X2 model is perfect for mobile medical responders. The vein finder device is priced to equip the entire team.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-80
Brands:: Scitek

Description

Working Principles:

Infrared vein finder lamp has a strong penetrating power on human soft tissues, while hemoglobin in human blood features the selective absorption of infrared light. The signal generated by this feature displays clear vein images on the screen through photoelectric, digital-to-analog conversion and software enhancement processing.

Vein Finder Device +Features:
  1. Adopts DLP in-situ projection technology to ensure greater reliability in determining the location of blood vessels.
  2. With the advantage of the loudest measurement depth of more than 6mm, it is suitable for different skin types and body structures and improves the reliability of vascular imaging, especially for the localization of deeper blood vessels.
  3. The infrared vein finder helps to penetrate the skin better and improves the vascular imaging effect, making it possible to obtain clear images even under low light conditions.
  4. The brightness adjustment function ensures that the blood vessels can be clearly visualized under different lighting conditions.
  5. Adopts 824X480 image resolution to ensure clear and detailed vascular images, which helps to perform vein puncture more accurately.
  6. Low power consumption helps to save energy and prolong the life of the device.

 

Vein Finder Specifications:
Model VF-X2
Development Mode DLP in situ projection, no laser
Maximum Sounding Depth ≥6mm
Infrared Wavelengths 850 nm
Rated Consumption 25VA
Standby Time ≥180min
Charging Time 3h (Shutdown state)
Image Resolution 824×480
Brightness Projection 1W 20 Lumens (The adjustable)
The Adjustable ≤0.2mm
Optimum Imaging Distance 200-250mm
Projection Color White light, green light, red light, three colors can be switched
Working Mode Normal mode, child mode, reverse color mode
Function Depth recognition (three kinds of depth cue), brightness adjustment
Run Time Environment WIN8.1operating system
Frame Frequency 30 Frames per second
Support Benchtop(standard) / Floor (optional)
Shipping Size(W×D×H)(mm) Main Machine: 330x280x180
Stand: 630x630x190
G.W. (kg)(Including Stand) 11
Applications of Vein Finder:
  1. Medical field: It is more convenient to locate patient’s blood vessels, improve the accuracy of venipuncture, and reduce unnecessary pain and injury.
  2. Nursing: In hospitals, clinics and nursing institutions, it is used to assist nursing staff to locate blood vessels and improve the efficiency of venous blood collection and transfusion.
  3. Operating theatre: During surgery, vein finder helps doctors to locate the patient’s veins accurately and reduce complications during surgery.
  4. Pediatrics: The vein finder’s child mode and brightness adjustment features increase the ease of use for pediatric patients.

 

Reviews

There are no reviews yet.

Be the first to review “Versatile Infrared Vein Finder”

Your email address will not be published. Required fields are marked *

Quick Comparison

Versatile Infrared Vein Finder removeAGD Erma EL-120 ELectrolyte Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer removeAvalun LabPad Device removePlastic Urine Container Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
NameVersatile Infrared Vein Finder removeAGD Erma EL-120 ELectrolyte Analyzer removeSkyla Hi POC Clinical Chemistry Analyzer removeAvalun LabPad Device removePlastic Urine Container Per Pack removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
ImageAvalun Labpad machine
SKUSF1033560130127-80SF1033560084-125SF1033560060-2SF1033560084-65SF1033560084-106SF1033560060-1
Rating
Price

$0.00

$1,320.00

$0.00

$0.00

$8.20

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad Model: VF-X2 The rugged and easy-to-use VF-X2 model is perfect for mobile medical responders. The vein finder device is priced to equip the entire team.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Abroad
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla Hi POC Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results.The use of skyla Hi in the management of diabetes enables better access to testing and rapid clinical decision making, discussion,and implementation of optimized treatment. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Working Principles:
Infrared vein finder lamp has a strong penetrating power on human soft tissues, while hemoglobin in human blood features the selective absorption of infrared light. The signal generated by this feature displays clear vein images on the screen through photoelectric, digital-to-analog conversion and software enhancement processing.
Vein Finder Device +Features:
  1. Adopts DLP in-situ projection technology to ensure greater reliability in determining the location of blood vessels.
  2. With the advantage of the loudest measurement depth of more than 6mm, it is suitable for different skin types and body structures and improves the reliability of vascular imaging, especially for the localization of deeper blood vessels.
  3. The infrared vein finder helps to penetrate the skin better and improves the vascular imaging effect, making it possible to obtain clear images even under low light conditions.
  4. The brightness adjustment function ensures that the blood vessels can be clearly visualized under different lighting conditions.
  5. Adopts 824X480 image resolution to ensure clear and detailed vascular images, which helps to perform vein puncture more accurately.
  6. Low power consumption helps to save energy and prolong the life of the device.
 
Vein Finder Specifications:
Model VF-X2
Development Mode DLP in situ projection, no laser
Maximum Sounding Depth ≥6mm
Infrared Wavelengths 850 nm
Rated Consumption 25VA
Standby Time ≥180min
Charging Time 3h (Shutdown state)
Image Resolution 824x480
Brightness Projection 1W 20 Lumens (The adjustable)
The Adjustable ≤0.2mm
Optimum Imaging Distance 200-250mm
Projection Color White light, green light, red light, three colors can be switched
Working Mode Normal mode, child mode, reverse color mode
Function Depth recognition (three kinds of depth cue), brightness adjustment
Run Time Environment WIN8.1operating system
Frame Frequency 30 Frames per second
Support Benchtop(standard) / Floor (optional)
Shipping Size(W×D×H)(mm) Main Machine: 330x280x180 Stand: 630x630x190
G.W. (kg)(Including Stand) 11
Applications of Vein Finder:
  1. Medical field: It is more convenient to locate patient's blood vessels, improve the accuracy of venipuncture, and reduce unnecessary pain and injury.
  2. Nursing: In hospitals, clinics and nursing institutions, it is used to assist nursing staff to locate blood vessels and improve the efficiency of venous blood collection and transfusion.
  3. Operating theatre: During surgery, vein finder helps doctors to locate the patient's veins accurately and reduce complications during surgery.
  4. Pediatrics: The vein finder's child mode and brightness adjustment features increase the ease of use for pediatric patients.
 
Electrolyte Analyzer ERMA EL-120 is ideal for medium to high volume Laboratories and Hospitals . It offers reliable, automated samples handling and work flow offences . It also allows measurement of specific ions, accurately and precisely . This supports fast diagnosis of critically ill patients and reduces the risks of patient discomfort associated with repeated sampling Precise & Accurate Results Economical to use Large Touchscreen Display with Graphical User Interface. Features:
  • Parameters: Na+,K+,Cl-, iCa++ / Li
  • It works on ISE principle
  • Sample Type: Whole blood, Serum, Plasma, Urine
  • Low reagent consumption
  • Sample requirement is only 90ul
  • 60 samples per hour
  • Automatic two point calibration after 4hrs and one point calibration with each sample analysis
  • Air bubble detection
  • Track reagents consumption and provides alerts
  • For low reagent volume
  • Precision testing facility to get CV and SD
  • Trilevel Quality Control with LJ plots of last 30days
  • Low aspiration volume
  • Fast sample processing
  • Accurate and Precise results
Technical Specifications:
Parameters Na+, K+, Cl– /Ca++
Principle Ion Selective Electrode (ISE)
Sample Type Analyses whole blood, serum, plasma and urine
Sample Volume ≤100 µL
Analysis Time ≤60 seconds
Throughout ≤60 samples per hour
Data Link Serial (RS232)
External Interface USB (Keyboard, Mouse)
Operating Condition 10° C to 35° C, Relative Humidity up to 85%
Storage Condition Temp: 10° C to 40° C
Relative Humidity up to 85% non- condensing
Power Supply 100 to 240 VAC ±10%, 50Hz
Dimensions 395 x 260 x 375 mm
Weight 7.5 kg
 
Click Here To Download Catalogue
skyla Hi Analyzer enables better access to testing and rapid clinical decision making, discussion, and implementation of optimized treatment. To get the result, only prepare <1 μl fingertips blood or venous blood (depends on test item) without pretreatment with easy steps and then read the result after 6 mins. The device allows two specimens be tested in one run and provides fully automatic procedures from checking the validity of cartridge to printing the results. Reagent Kit
  • HbA1C
  • CRP
  • Lipid Panel (TC,TG, HDL, LDL#)
  • Lipid Plus Panel (Glu,TC,TG, HDL, LDL#)
Main Specification
Principle
Turbidimetric Method / Biochemistry
Device
Testing Time
5~20 minutes (depends on test items)
Display and Interface
5″ TFT color touch screen LCD
Memory Capacity
50,000 test results
Dimension of Analyzer
270 x 188 x 148 mm
Weight of Analyzer
1.7 kg
Dimension of Printer Module
134 x 100 x 82.7 mm
Weight of Printer Module
0.37 kg
Power Supply
100~240 volts AC, 50-60Hz
Data Transmission
USB 2.0*4 / USB 3.0*1 / RS232*1 / RJ45*1 / Wi-Fi (optional)
Reagent and Samples
Samples
Fingertips blood or venous blood
Samples Volume
0.8 ~ 30 μL (depends on test item)
Storage Temperature (Reagent)
2 ~ 8˚C
Humidity
Relative humidity < 95% (Non-condensing)
Temperature
10 ~ 32 ˚C
Click Here To Download Catalogue
The coagulometer, LabPad® INR, measures blood coagulation time thanks to a patented optical technology. This portable In-Vitro Diagnostics (IVD) device works with the Tsmart® INR single-use microcuvettes.
  • User-friendly: the LabPad® INR is designed to be easy to use especially thanks to its 3D-shaped microcuvette that only requires a small drop of blood from a fingertip. Thanks to the color screen, both measurement steps and browsing the list of results are easy to visualize.
  • Quick and reliable: the reliability of INR results is obtained by quality controls that are performed automatically before each measurement. In less than one minute, you can see if you are in your therapeutic range.
  • Connected: the result obtained after performing the test can be transferred to healthcare professionals in charge of your treatment monitoring. This result is complementary to the pie charts and trend reports directly displayed on the LabPad® INR to help you monitoring your treatment
 
Click Here To Download Catalogue
   
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 
Click Here To Download Catalogue