Visible Spectrophotometer, Bandwidth 2/4nm

$0.00

Shipped From Abroad

Visible Spectrophotometer with a bandwidth of 2/4 nm measures the intensity of light within the visible spectrum (typically 400-800 nm) with high precision. The narrow bandwidth allows for more accurate and detailed measurements, making it ideal for applications requiring high resolution, such as chemical analysis and research.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-53
Brands:: Scitek

Description

Single Beam Visible Spectrophotometer Features:
  1. A 2.5 inch LCD screen is included to display standard curves and groups of results.
  2. Various standard curves can be established based on the customer’s solutions to determine the concentration of unknown solutions.
  3. The device has a USB port for data output, which can be connected to a PC to display spectrum scanning, kinetics, and multi-wavelength testing results on the screen.
  4. The device can display wavelength, absorption, and transmittance with 5 results per screen and store up to 200 results in its memory.
  5. Users can set the wavelength automatically using arrow keys to avoid operation errors.

 

Single Beam Visible Spectrophotometer Specifications:
Model SP-V5100
Optical System Single beam, Grating 1200 lines/mm
Wavelength Range 325-1000nm
Bandwidth 4nm(optional 2nm)
Wavelength Accuracy ±2nm
Wavelength Repeatability 0.5nm
Wavelength Setting Auto
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Photometric  Mode T, A, C, F
Stray Light ≤0.1%T
Stability ± 0.002A/h @ 500nm
Display 128×64  LCD
Detector Silicon Photodiode
Light Source Tungsten Lamp
Output USB Port & Parallel Port (Printer)
Power Requirements AC 85~250V
Size(W×D×H)(mm) 420x280x180
Shipping Size(W×D×H)(mm) 600x460x330
N.W./G.W. (kg) 10/14

Reviews

There are no reviews yet.

Be the first to review “Visible Spectrophotometer, Bandwidth 2/4nm”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsVisible Spectrophotometer, Bandwidth 2/4nm removeiSED Fully Automated ESR Analyzer removeAlcohol Pad Per Pack removeEppendorf Pipette Tip 200ul Per Pack removeAvalun 48 INR Microcuvette remove8 Bucket Centrifuge remove
NameVisible Spectrophotometer, Bandwidth 2/4nm removeiSED Fully Automated ESR Analyzer removeAlcohol Pad Per Pack removeEppendorf Pipette Tip 200ul Per Pack removeAvalun 48 INR Microcuvette remove8 Bucket Centrifuge remove
ImageEppendorf Pipette Tip 200ul Per PackAvalun 48 INR Microcuvette
SKUSF1033560130127-53SF1033560084-129SF1033560084-64SF1033560084-137SF1033560084-74SF1033560084-114
Rating
Price

$0.00

$0.00

$4.25

$0.00

$0.00

$72.50

Stock

Out of stock

AvailabilityOut of stock
Add to cart

DescriptionShipped From AbroadVisible Spectrophotometer with a bandwidth of 2/4 nm measures the intensity of light within the visible spectrum (typically 400-800 nm) with high precision. The narrow bandwidth allows for more accurate and detailed measurements, making it ideal for applications requiring high resolution, such as chemical analysis and research.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Out stock LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users. Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Single Beam Visible Spectrophotometer Features:
  1. A 2.5 inch LCD screen is included to display standard curves and groups of results.
  2. Various standard curves can be established based on the customer's solutions to determine the concentration of unknown solutions.
  3. The device has a USB port for data output, which can be connected to a PC to display spectrum scanning, kinetics, and multi-wavelength testing results on the screen.
  4. The device can display wavelength, absorption, and transmittance with 5 results per screen and store up to 200 results in its memory.
  5. Users can set the wavelength automatically using arrow keys to avoid operation errors.
 
Single Beam Visible Spectrophotometer Specifications:
Model SP-V5100
Optical System Single beam, Grating 1200 lines/mm
Wavelength Range 325-1000nm
Bandwidth 4nm(optional 2nm)
Wavelength Accuracy ±2nm
Wavelength Repeatability 0.5nm
Wavelength Setting Auto
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Photometric  Mode T, A, C, F
Stray Light ≤0.1%T
Stability ± 0.002A/h @ 500nm
Display 128x64  LCD
Detector Silicon Photodiode
Light Source Tungsten Lamp
Output USB Port & Parallel Port (Printer)
Power Requirements AC 85~250V
Size(W×D×H)(mm) 420x280x180
Shipping Size(W×D×H)(mm) 600x460x330
N.W./G.W. (kg) 10/14
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
Alcohol Pad (70% Isopropyl Alcohol Pre Pad, Alcohol Cleansing Swab). Clean the required area. Discard after single use. Size and packing of Medical Alcohol pad:
  • Pad Size: Unfolded: 30 x 60 mm (other size can be request ).
  • Folded: 30x30 mm, 30 x 35mm,can be 2ply or 4ply ( other size, ply can be request ).
  • Aluminum Package: 60 x 50 mm , 50 x 50mm approximate ( other size can be request ).
  • Packing: 100/200 pcs per inner box, 50/ 100 boxes per carton(packing can be request).
Use of Medical Alcohol pad:
  • For cleaning prior to injection or to disinfect the hurted skin for family and medical treatment organization use.
  • For preparation and immediate disinfection of skin, wound area orr Instrument and utensil.
Notice of Medical Alcohol pad:
  • Not for eyes;
  • keep out of reach of children;
  • For external use only;
  • please stop using if you feel allergic or amyctic
Materials - Non-Woven Fabric
Trademark - OEM/ODM
Specification - CE&ISO13485
   
  • Made of high quality PP material with good transparency.
  • Applied for Gilson/Finland/Eppendorf Pipettors.
  • Carefully inspect of raw material and manufactured under strict process check, all tips are with excellent accuracy and precison.
  • Special siliconizing on the inner surface ensure no liquid adhesion and accurate sample transfer.
  • Standard tips and filter tips can be autoclaved, high temperature sterilization acceptable.
  Classification: PIPETTE Brand Name: Vchanslab,Yingmed,OEM Model Number: YM-K7028 Place of Origin: China Product name: Pipette Tips Material: Polypropylene Certificate: CE/ISO13485/FDA Color: Natural, Blue, Yellow Application: Laboratory, Teaching, Hospital
LabPad®’s versatility comes especially from its Tsmart® single-use microcuvette, which contains a lyophilized reagent specific to each test. The Tsmart® microcuvette is the fruit of numerous innovations that have led to many benefits for users.
Features:
  • Fully automated "plug-and-play"   behavior
  • Reduced blood volume (only 3µL)
  • A large space for blood drop-off
  • Fills up quickly, using just capillarity
  • Easy handling, thanks to its 3D shape
  • Optimized preservation in individual pouches, in boxes of 12, 24, or 48 units
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare