Visible Spectrophotometer Spectrum Bandwidth 5nm

$0.00

Shipped From Abroad

The visible spectrophotometer measures the light absorbed by a sample within the visible spectrum (400-800 nm). It’s crucial in determining the concentration of substances, by passing light through a sample and measuring the absorption at various wavelengths.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
SF1033560130127-51
Brands:: Scitek

Description

Visible Spectrophotometer Features:
  1. Sample chamber for 5-100mm cuvettes
  2. Precise automatic T/A conversion
  3. RS232 interface
  4. Direct concentration reading and concentration factor setting
  5. Automatic zero and full scale adjustment
  6. Standard software (SP-VG721)
  7. Optional dedicated printer (SP-VGI721)

 

Common Features
  1. High quality silicon photodiode detector and 1200 lines/mm diffraction grating ensure high quality accuracy and precision.
  2. Automatic 0%A and 100%T.
  3. Backlit LED display for easy reading.
  4. Easily switch between transmittance, absorbance and concentration modes.
  5. Users can easily change halogen or deuterium lamps on their own.
  6. Direct concentration readout and concentration factor setting capability.
  7. Cuvettes from 5 – 100mm optical lengths with optional holders.

 

Visible Spectrophotometer Specifications:
Model SP-VG722 SP-VGI721 SP-VG721
Photometry Single Beam
Monochromator Type Czerny-Turner
Detector Silicon Photocell
Wavelength Setting Manual Turn Knob
Wavelength Range 325-1000nm 340-1000nm
Wavelength Accuracy ±2nm
Wavelength Repeatability ≤1nm
Spectrum Bandwidth 5nm
Stray Light ≤0.5%T (at 360nm NaNo2)
Photometric Range 0-100.0%T
0-1.999A
0-1999C
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Noise 100% (T) noise ≤0.3% (T), 0% (T) noise ≤0.2% (T)
Drifting ±0.5 %T/3min
Cuvette Holder Size 50mm 100mm 50mm
Power AC220V±22V; 50Hz±1Hz, 50W
Size(W×D×H)(mm) 400x300x200
Shipping Size(W×D×H)(mm) 560x500x300
N.W./G.W. (kg) 13/15

Reviews

There are no reviews yet.

Be the first to review “Visible Spectrophotometer Spectrum Bandwidth 5nm”

Your email address will not be published. Required fields are marked *

Quick Comparison

SettingsVisible Spectrophotometer Spectrum Bandwidth 5nm removeErma B-111 Bilirubin Meter removePlastic Urine Container Per Pack remove8 Bucket Centrifuge removeiSED Fully Automated ESR Analyzer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
NameVisible Spectrophotometer Spectrum Bandwidth 5nm removeErma B-111 Bilirubin Meter removePlastic Urine Container Per Pack remove8 Bucket Centrifuge removeiSED Fully Automated ESR Analyzer removeSkyla HB1 POC Clinical Chemistry Auto Analyzer remove
Image
SKUSF1033560130127-51SF1033560084-6SF1033560084-106SF1033560084-114SF1033560084-129SF1033560060-1
Rating
Price

$0.00

$715.00

$8.20

$72.50

$0.00

$0.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad The visible spectrophotometer measures the light absorbed by a sample within the visible spectrum (400-800 nm). It’s crucial in determining the concentration of substances, by passing light through a sample and measuring the absorption at various wavelengths.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped From Aboard  The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin.

Delivery & Availability:

Typically 2 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
Classification: Laboratory Centrifuge
Brand Name: xiangtian
Model Number: 800-1
Place of Origin: Jiangsu, China
Time range: 0-60min
Max speed: 4000r/min
Max RCF: 1790xg
Capacity: 20ml*6
  Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The skyla HB1 Clinical Chemistry Analyzer provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. The portable design of the clinical chemistry analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. Delivery & Availability: Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Visible Spectrophotometer Features:
  1. Sample chamber for 5-100mm cuvettes
  2. Precise automatic T/A conversion
  3. RS232 interface
  4. Direct concentration reading and concentration factor setting
  5. Automatic zero and full scale adjustment
  6. Standard software (SP-VG721)
  7. Optional dedicated printer (SP-VGI721)
 
Common Features
  1. High quality silicon photodiode detector and 1200 lines/mm diffraction grating ensure high quality accuracy and precision.
  2. Automatic 0%A and 100%T.
  3. Backlit LED display for easy reading.
  4. Easily switch between transmittance, absorbance and concentration modes.
  5. Users can easily change halogen or deuterium lamps on their own.
  6. Direct concentration readout and concentration factor setting capability.
  7. Cuvettes from 5 - 100mm optical lengths with optional holders.
 
Visible Spectrophotometer Specifications:
Model SP-VG722 SP-VGI721 SP-VG721
Photometry Single Beam
Monochromator Type Czerny-Turner
Detector Silicon Photocell
Wavelength Setting Manual Turn Knob
Wavelength Range 325-1000nm 340-1000nm
Wavelength Accuracy ±2nm
Wavelength Repeatability ≤1nm
Spectrum Bandwidth 5nm
Stray Light ≤0.5%T (at 360nm NaNo2)
Photometric Range 0-100.0%T
0-1.999A
0-1999C
Photometric Accuracy ±0.5%T
Photometric Repeatability ≤0.2%T
Noise 100% (T) noise ≤0.3% (T), 0% (T) noise ≤0.2% (T)
Drifting ±0.5 %T/3min
Cuvette Holder Size 50mm 100mm 50mm
Power AC220V±22V; 50Hz±1Hz, 50W
Size(W×D×H)(mm) 400x300x200
Shipping Size(W×D×H)(mm) 560x500x300
N.W./G.W. (kg) 13/15
The advanced B111 Bilirubinmeter provides fast, accurate results for Total bilirubin level in neonates with only 40μl serum or plasma sample. It determines total bilirubin by dual wavelength photometric analysis. Suited for pediatric setups, small workload labs & hospitals because of its compact and portable design. Advanced, benchtop and precise instrument for measuring Total Bilirubin. Feature
  • Auto zero function: Manual blanking not required
  • Dual wavelength measurement system:
  • 2 wave lengths 455nm and 575nm
  • Plays major role to remove the interference caused due to Hemolysis & turbidity of sample
  • LED Light source:
  • LED does not require replacement as it lasts longer
  • As compared to Lamp, LED are more suitable as there is no intensity fluctuations
  • No warm up time required.
  • Flexible unit selection:
  • Two units either mg/dl or umol/L are selectable, ease of reporting
  • Compact slot for Capillary:
  • Accuracy of results are directly related to proper alignment of Capillary
  • B-111 has the easiest mode to ensure precise values
  • Data transfer:
  • External device can be connected to instrument through RS232 por
  • USB port
Technical Specification
  • Light source - LED
  • Wavelength - 455nm and 575nm
  • Net weight - 1kg
  • Measuring range - 0-30 mg/dl , 510 umol/L
  • Display - 16×2 LCD module with backlight
  • Auto calibration - Yes
  • Sample type - Serum or plasma
  • Sample volume - 40-80μL
  • Test time - <5sec
  • Units - mg/dl or umol/L
  • Dimensions - 150 (W) × 115 (H) × 190 (D) mm
  • Interface - RS232
  • Reading cuvette - Heparinized micro capillary holder
  • Storage temperature - 15-40°c
  • Power supply - DC 9V(DC adapter)
  • Power consumption - <2W
  • Total Volume: 60mL.
  • Specimen Container, Leak-proof, Ideal for Pathology/Histology/Cytology reagent pre-filling sample preparation.
  • Made of premium PP material, it is durable for usage.
  • Some measurements can be used to not only use urine samples, it can also be used for other liquids.
800-1  electric centrifuge is widely used in hospitals, chemical and Biological Chemistry Laboratory for serum, plasma, immune qualitative analysis experiment. Has beautiful shape, large capacity, small volume, complete function. Its performance is stable, the speed is adjustable and can automatically adjust the balance, low temperature, high efficiency and wide applicability and advantages. Technical Specifications:
Type No.
800-1
Power  source
220V 50HZ     110V  60HZ
Speed Range (rpm)
0~4000(rpm)
Time Range(min)
0-60min
Capacity (ml)
20(ml)×6
Maximum centrifugal force(xg)
1790(xg)
Package Size (cm)
29*29*26
 
Click Here To Download Catalogue
The technical innovation of the iSED® fully-automated ESR analyzer consists of directly measuring the intensity of the red cell aggregation which is responsible for Erythrocyte Sedimentation Rate (ESR). Unlike traditional ESR methodologies that measure the aggregation of the red blood cells indirectly, the iSED measures it directly and expresses the values in mm/hr. Features:
  • Results in 20 Seconds

  • 100µL sample drawn directly from primary EDTA tube

  • Fully automated, walk-away operation

  • Random access

  • Positive patient identification via internal barcode reader

  • Compatible with pediatric tube

     
Technical Specifications: 
Principle of Measure: Photometrical
Results: “Printed mm/hr, Range from 1-130 mm/hr”
Sample Requirements: 500uL whole blood, collected in EDTA anti-coagulant tested 24 hours from venipuncture at room temperature or refrigerated.
Tube Requirements: 13 x 75 mm, pierceable capped tube
Quality Control: Barcoded Seditrol® QC
Barcode Reader: Internal
Printer: Internal
Interface Specifications: serial RS232 port for LIS connection
Weight: 14 kg
Dimensions (H x W x D): 36 x 27 x 34 (cm) /14.3 x 10.5 x13.4 (in)
Voltage: 100-240VAC
Frequency Range: 50-60 Hz
Power: 160W
Click Here To Download Catalogue
Skyla HB1 Clinical Chemistry Analyzer utilizes precision photometric measurement technology, combined with the single-use disposable reagent discs. The reagent disc contains a set of dry assay reagents that are used in the quantitative testing of various biomarkers in the blood sample. HB1 provides clinical testing laboratories of medical facilities and clinics with an in-vitro clinical chemistry diagnostic tool that is compact, portable, and reports rapid results. Only needs 200µl of blood (whole blood, serum or plasma is accepted.) and no sample preparation is required. All steps are designed automatically from checking the validity of reagent discs and cartridges to printing the results. Over 30 test parameters are allowed with fast analysis and results in 15 minutes. Internal Quality Control (IQC) with self-calibration of optical system, chemicals stability and interference alerts functions monitor and ensure the results with high accuracy. Available Test Panels
  • Renal Function - BUN, CREA eGFR
  • Liver Function - ALB, TP, ALP, ALT, AST, TBIL, DBIL, GGT, LDH A/G#, GLOB#, IBIL
  • Lipid Metabolism - TG, TC, HDL LDL#, VLDL
  • Pancreatitis Markers - AMY, LIPA
  • Carbohydrate Metabolism and Others - GLU , CPK, UA, LAC
  • Inflammatory Markers - CRP
  • Electrolyte - Na, K, Cl, Ca, PHOS, Mg, tCO2
SPECIFICATION Principle
  • Colormetric System : LEDs 340nm~940nm wavelength
Sample & Panel
  • Test Profiles : Panels
  • Measurement Time - Panel: up to 15 tests/ 15 min
  • Sample Type & Volume : 200 μl whole blood (PCV<60%), plasma, serum 
Device
  • User Interface : 5 inch color LCD touch screen
  • Internal Memory : Store up to 50,000 analysis results
  • Printer : Built in thermal printer or external USB printer (PCL 3GUI)
  • USB Socket : USB type A (Host) for external USB Printer, USB flash drive (FAT) or external barcode scanner
  • Data transmission to PC : RS232 serial port or RJ45 (LAN)
  • Dimensions : 233 (W) X 285 (D) X 300 (H) mm
  • Weight : 5.5 kg
Operating Condition
  • Temperature / Humidity : 10 to 32˚C / 5 to 90 %
 