980nm Diode laser Vascular Removal

$0.00

Shipped From Abroad

A diode laser system operating at 980 nm with a 50 W fiber handle and three tips, V980 treats redness and spider veins precisely while promoting skin health.

Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Brands:: Sanhebeauty

Description

Product Description

The V980 is a 980 nm diode laser system tailored for treating spider veins, redness, and small vascular lesions. Its high-power fiber handle (50 W), adjustable pulse (20–100 ms), and multiple tips allow precise targeting. The system’s 980 nm wavelength is highly absorbed by hemoglobin, collapsing capillaries while stimulating collagen for improved skin resilience.

Key Features
  • Targeted 980 nm Diode Laser: High absorption by hemoglobin ensures selective vessel treatment.

  • 50 W Fiber Handle: Delivers powerful, consistent energy.

  • Three Treatment Tips: Supports different vessel sizes.

  • Adjustable Pulse Width (20–100 ms): Customizable coagulation depth.

  • 17″ Touchscreen Interface: Simplifies setup and control.

  • Air Cooling System: Maintains performance for continuous operation.

  • Collagen Biostimulation: Enhances epidermal thickness and skin elasticity.

Reviews

There are no reviews yet.

Be the first to review “980nm Diode laser Vascular Removal”

Your email address will not be published. Required fields are marked *

Quick Comparison

980nm Diode laser Vascular Removal removeOPTIKA B-382PL-ALC Binocular Brightfeld Microscope removeUrine Analyzer removeMayo Table removeHospital Trolley removeKick About remove
Name980nm Diode laser Vascular Removal removeOPTIKA B-382PL-ALC Binocular Brightfeld Microscope removeUrine Analyzer removeMayo Table removeHospital Trolley removeKick About remove
Image980nm Diode laser Vascular RemovalOPTIKA B-382PL-ALC Binocular Brightfeld Microscope
SKUSF1033560098-13SF1033560084-224SF1033560084-239SF1033560084-237SF1033560084-238
Rating
Price

$0.00

$0.00

$540.00

$48.00

$48.00

$28.00

Stock
Availability
Add to cart

DescriptionShipped From Abroad A diode laser system operating at 980 nm with a 50 W fiber handle and three tips, V980 treats redness and spider veins precisely while promoting skin health.
Delivery & Availability: Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Shipped from Abroad The OPTIKA B-380 is an educational and laboratory microscope for routine applications. Dye-cast frame, with high stability and ergonomy, for transmitted light observation. Delivery & Availability: Typically 21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.In stock Used for Clinical Diagnostics.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Material Stainless: Steel Height Adjustable: Yes Number of Wheel: 4 Height: 3-4 Feet
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock Dimension (mm): L550 x W420 x H880 mm Color: Grey Material: Stainless steel No of wheel: 4
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
In stock
  • Supplied with one 35 cms. dia. S.S. Basin.
  • Stainless steel pipe construction mounted on three 10 cms. dia. castors.
Delivery & Availability: Typically 5-7 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
Content
Product Description

The V980 is a 980 nm diode laser system tailored for treating spider veins, redness, and small vascular lesions. Its high-power fiber handle (50 W), adjustable pulse (20–100 ms), and multiple tips allow precise targeting. The system’s 980 nm wavelength is highly absorbed by hemoglobin, collapsing capillaries while stimulating collagen for improved skin resilience.

Key Features
  • Targeted 980 nm Diode Laser: High absorption by hemoglobin ensures selective vessel treatment.

  • 50 W Fiber Handle: Delivers powerful, consistent energy.

  • Three Treatment Tips: Supports different vessel sizes.

  • Adjustable Pulse Width (20–100 ms): Customizable coagulation depth.

  • 17″ Touchscreen Interface: Simplifies setup and control.

  • Air Cooling System: Maintains performance for continuous operation.

  • Collagen Biostimulation: Enhances epidermal thickness and skin elasticity.

Observation mode: Brightfield. Head: Binocular, 30° inclined, 360° rotating (when ALC cable is unplugged). Interpupillary distance: Adjustable between 48 and 75 mm. Dioptric adjustment: On the left eyepiece tube. Eyepieces: WF10x/20 mm, high eye-point and secured by screw. Nosepiece: Quintuple revolving nosepiece, rotation on ball bearings. Objectives: N-PLAN 4x/0.10 N-PLAN 10x/0.25 N-PLAN 40x/0.65 N-PLAN 100x/1.25 (Oil/Water) All with anti-fungus treatment. Specimen stage: Double layer rackless mechanical stage, 150×139 mm, 75×33 mm X-Y range. Focusing: Coaxial coarse (adjustable tension) and fine focusing mechanism with limit stop to prevent the contact between objective and specimen. Condenser: Abbe N.A. 1.25, with objective-coded iris diaphragm, focusable and centerable. Illumination (Fixed Koehler type): X-LED3 with white 3.6 W LED (6,300K) and brightness control. ALC system. Multi-plug 100-240Vac/6Vdc external power supply.  
Click Here To Download Catalogue
Used for Clinical Diagnostics.
  • Test Method: Dry Strip color-developing method
  • Test Principle: Dual wavelength reflectance photometry
  • Light Source: Cold Lamp with high brightness and long lifetime
  • Test System: Color-indentify system with high sensitivity and repeatability
  • Wavelength: 520nm, 640nm, 660nm
  • Throughput: 120 Strips/Hour
  • Test Mode: Single and continuous test mode are selectable
  • Test Slot: Using sliding Slot, Easy to clean and replace, lower the carryover
  • Waste Collection: Waste urine and waste strips can be collected automatically
  • Test Strip: Use GENIUS original strips only
  • Display: LCD with high brightness and resolution
  • Language: Customizable language software
  • Memory: Save 2000 samples results, and auto recover the results when power off during working
  • Interface: RS-232 serial port, can be connected to external printer and computer Printer: Inner thermal printer, can be connected to external printer
  • Report format: Half quantitative and qualitative, report the color and turbidity is available
  • Result unit: SI unit and routine unit are selectable
  • Status Check: Auto-check the status during power on and off, auto-indentify the alarm
  • Working Environment: Temperature10℃~30℃; Humidity: 20%RH~80%RH
  • Power: 100-240V, Auto adapt according to the input voltage
  • Consumption: ≤80VA
  • Quality System: Certified by TUV and CMD
Material Stainless Steel
Height Adjustable Yes
Number of Wheel 4
Height 3-4 Feet
Dimension (mm) L550 x W420 x H880 mm
Color Grey
Material Stainless steel
No of wheel 4
  • Supplied with one 35 cms. dia. S.S. Basin.
  • Stainless steel pipe construction mounted on three 10 cms. dia. castors.
WeightN/AN/AN/AN/AN/AN/A
DimensionsN/AN/AN/AN/AN/AN/A
Additional information
Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • Rating
  • Price
  • Description
Click outside to hide the comparison bar
Compare