| Description | Shipped From Abroad
JD-2000 Auto Lensmeter delivers fast, precise lens measurements with LCD display, automatic recognition, and user-friendly operation for eye care professionals.
Delivery & Availability:
Typically 10-21 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
The NJC-4 Lensmeter is used to measure the diopters of spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of lens, the axis of cylinder len and the base direction of shuttle lens.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Software image workstation
- B, B+B, B+A, A modes
- Video review for 100 images
- PDF report output
- Optional 20MHz B Probe: vitreous plus function
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Ship from abroad
- Easy installation and maintenance: It is quite easy to replace light bulks, and unnecessary to adjust its focus and position.
- Customer Programmable: Icons can be displayed in predefined sequence by programming.
- Display Single Icon: Display single icon by multi-function mask plate.
- Tilted Placement: Perfect image position can be obtained by adjusting the horizontal axis of projector.
- Standards parts: Metal plate with polarized coating (410x 410mm)
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
- Large color liquid-crystal screen
- Touch screen input, easy operation
- Curve freezing: Manual/Auto mode, controlled by pedal
- Built-in speed thermal printer
- Enter the name & ID; easy to check archive
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
| Shipped from abroad
This ultra-portable is an excellent diagnostic instrument for the examination of anterior segment structures and ocular abnormalities.
Delivery & Availability:
Typically 14 working days – excluding furniture and heavy/bulky equipment. Please contact us for further information.
|
| Content | The JD-2000 Auto Lensmeter is a precise and user-friendly device designed for quick and accurate measurement of optical lenses. It supports single vision, progressive, and contact lens measurements, offering reliability in both clinical and optical shop settings. With its advanced technology, clear LCD display, and fast processing speed, the JD-2000 ensures efficient workflow and dependable results.
Key Features
-
Automatic measurement of single, progressive, and contact lenses
-
High-precision sphere, cylinder, axis, and prism measurements
-
Easy-to-read LCD display for enhanced visibility
-
Fast measurement response for increased efficiency
-
Compact and ergonomic design for convenience
-
Suitable for optical shops, clinics, and laboratories
Technical Specifications
| Range of measurement |
| Sphere |
0~±25m-1 0.01/0.12/0.25m-1 step |
| Cylinder |
0~±9.99m-1 0.01/0.12/0.25m-1 step |
| Axis |
0°~180° (1°step) |
| Add. |
0~+9.99m-1Â 0.01/0.12/0.25m-1Â step |
| Prism degree |
0~15m-1Â 0.01/0.12/0.25m-1Â step |
| Measurement mode |
| Cylinder |
+,+/-,- |
| Prism |
X-Y, P-B |
| Contact lens |
Soft/hard lens |
| Measuring mode |
Single/progressive/ automatic recognition |
| Specifications |
| Diameter of lens |
Φ20~Φ108mm |
| PD |
40~90mm, 0.5mm step |
| Speed of measurement |
0.1second |
| Display |
7″LCD/TFT |
| Printer |
Thermal printer |
| Dimension |
196mm*286mm*442mm |
| Weight |
~6kg |
| Power supply |
100~240V 50~60Hz |
| The NJC-4 Lensmeter is used to measure the diopters of the spherical lens and cylinder lens, the axis of cylinder lens, the strength and the baseline direction of shuttle lens, it can also stamp the optical center of the lens, the axis of cylinder lens, and the base direction of shuttle lens. This instrument (Both Ac and Dc are permitted Two cells When Dc) has clear readings and graduations as well as high objective precision and reliabilities except that it can be operated easily and conveniently, AU the lenses and the made glasses can be measured by it, therefore, it is a required and ideal measuring instrument for glasses manufactures, glasses stores and ophthalmological hospitals.
Technical Specifications:
- Eyepiece focusing range: ±5D
- The top point diopter measuring range: 0—±20D
- The minimum measuring square value: 0.125D
- The shuttle lens measuring range: 5A
- The shuttle lens square value: 1A
- The cylinder lens axial range: 0—180°
- The cylinder lens axial square value: 5°
- The maximum diameter of the measured lenses l00m/m
- Power supply: AC 110V-6V DC 3V
- Note: This item is AC 110V; The battery is not included!
| Functions of Ophthalmic AB Scan Machine:
- Software image workstation
- B, B+B, B+A, A modes
- Video review for 100 images
- PDF report output
- Optional 20MHz B Probe: vitreous plus function
Technical Specifications:
| A scan |
1.Probe: 10MHz frequencies, with LED
2.Depth: 40mm
3.Precision: ±0.05mm
4.Eye mode: Phakic / Aphakic / Dense / Various IOL
5.Measurement: Anterior chamber depth, lens thickness, vitreous body length, total length and average
6.IOL Formula: SRK-II, SRK-T, BINKHORST, HOLLADAY, HOFFER-Q, HAIGIS, Stat.
7.Calculation: Average and standard deviation
8.Store: 10 Scanning results for each eye |
| B scan |
1.Probe: 10MHz/20MHz (optional), Magnetic driven, noiseless
2.Scanning Mode: Sector Scanning
3.Resolution: Lateral ≤0.3mm; Vertical≤0.2mm
4.Geometric Location Precision: Lateral≤10%; Vertical≤5%
5.Depth: 60mm
6.Enhance the part of vitreous body and retina
7.Gain of probe:30dB-105dB
8.Scanning Angle : 53°
9.Gray Scale: 256
10.False Color: Multi colors OTC
11.Measure Mode: distances, perimeter and area
12.Movies: 100 images movie review,AVI ZIP JPG format image output
13.Output: PDF format case report, connect to normal printer |
| Others |
1.Display Mode :B, B+B, B+A, A
2.Hint: preset keyword
3.Case Search: Multi-keywords
4.Working Platform: Windows XP, VISTA, WINDOWS7
5.User-defined report template |
| Digital Chart Projector-Features:
- Easy installation and maintenance: It is quite easy to replace light bulks, and unnecessary to adjust its focus and position.
- Customer Programmable: Icons can be displayed in predefined sequence by programming.
- Display Single Icon: Display single icon by multi-function mask plate.
- Tilted Placement: Perfect image position can be obtained by adjusting the horizontal axis of projector.
- Standards parts: Metal plate with polarized coating (410x 410mm)
Technical Specifications of Digital Chart Projector:
|
Projection Distance |
1.5m~6m |
|
Projection Magnification |
30x (at 5m) |
|
Projection Size |
330x270mm (at 5 m) |
|
Chart Switching Speed |
One chart per 0.03s |
|
Mask Switching Speed |
1 open, 5 horizontal different lines, 8 vertical lines, 21 single letters, 1 red/green |
|
Program |
2 sets programs, each program contains up to 30 steps |
|
Speed of mask conversion |
One mask per 0.03s |
|
Lamp |
LED lamp |
|
Auto-off function |
After 10 minutes idle time |
|
Power Source |
AC 220V, 50Hz or 110V, 60Hz |
|
Power consumption |
40W |
|
Accessories |
Remote control, polarized metal screen, halogen lamp, polarized glasses, fuses (2), batteries (2) |
| Feature:
- Large color liquid-crystal screen
- Touch screen input, easy operation
- Curve freezing: Manual/Auto mode, controlled by a pedal
- Built-in speed thermal printer
- Enter the name & ID; easy to check the archive
Technical Specifications:
| Model |
SW-1000 Ophthalmic A Scan Biometer |
| A Scan |
| A scan probe |
10MHz import small size probe, built-in luminotron |
| Measuring range |
15mm-40mm |
| Measurement precision |
±0. 05mm; with macula lutea trace function |
| Measurement |
Anterior chamber depth, lens thickness, vitreous body length, total length and average |
| Method of measurement |
immersion and contact |
| Eye mode |
Phakic/ Aphakic/Dense/ various IOL |
| IOL formula |
SRK-II, SRK-T, BINKHORST-Â â…¡, HOLLADAY, HOFFER-Q, HAIGIS |
| Storage |
10 cases, 5 readings each case |
| Output |
A scan waveform and IOL calculation sheet
|
| Features:
- Ultra-portable: This ultra-portable is an excellent diagnostic instrument for the examination of anterior segment structures and ocular abnormalities. Its easy-to-operate optical system produces a high-brightness, continuously adjustable slit image ideal for pediatric and geriatric setting, emergency department screenings, ward rounds, beside examination, post-op evaluations, and mission work;
- LED illumination: the first and the only portable slit lamp in the world applying LED illumination system. The most prominent advantage of our LED illumination system gives the examiner the clearest image without glare;
- Comfortable using experience: The low heat radiation from our LED lamp makes the most comfortable examine experience for the patient;
- Sharpest Slit: With the blade imaging system S150 gives equally sharpest slit as the best classic slit lamp in the world;
- No need to replace illumination lamp: The LED lamp used in S150 portable slit lamp is rated 20,000 hours at full power. Its lifetime is almost 10 times longer than a normal halogen lamp;
- Power-saving: S150 can work for long hours without changing batteries.
Technical Specifications:
- Magnification: 5x
- Range of slit length: 5mm~11mm
- Minimum slit width: 0.2mm
- Working distance: 12~32mm
- Power supply: AA batteries x 2
- Illumination: LED blub(3.3V/1W)
- Battery life: More than 3h(AA alkaline batteries x 2)
- Net weight: 150g(without batteries)
How to Operate:
- Press the Power Switch to turn the slit lamp on/off
- Loosen the Locking Screw
- Twist the Lamp Body while holding the Magnifier Bracket still till the slit is in the required angle
- Push or pull the Lamp Body while holding the Magnifier Bracket still to set the Magnifier into a position comfortable for observation
- Fasten the Locking Screw
- Pull the Lamp Head back and forth for adjusting the width and the length of the slit, as well as the intensity of the light
|
Reviews
There are no reviews yet.